Arxiv:2003.13443V1 [Astro-Ph.IM] 26 Mar 2020 Minimum in the Phase Quadrature, Thus Reducing Shot Broadband Improvement in Sensitivity

Arxiv:2003.13443V1 [Astro-Ph.IM] 26 Mar 2020 Minimum in the Phase Quadrature, Thus Reducing Shot Broadband Improvement in Sensitivity

Frequency-Dependent Squeezing for Advanced LIGO L. McCuller,1, ∗ C. Whittle,1, y D. Ganapathy,1 K. Komori,1 M. Tse,1 A. Fernandez-Galiana,1 L. Barsotti,1 P. Fritschel,1 M. MacInnis,1 F. Matichard,1 K. Mason,1 N. Mavalvala,1 R. Mittleman,1 Haocun Yu,1 M. E. Zucker,1, 2 and M. Evans1 1LIGO, Massachusetts Institute of Technology, Cambridge, MA 02139, USA 2LIGO, California Institute of Technology, Pasadena, CA 91125, USA (Dated: March 31, 2020) The first detection of gravitational waves by the Laser Interferometer Gravitational-wave Observatory (LIGO) in 2015 launched the era of gravitational wave astronomy. The quest for gravitational wave signals from objects that are fainter or farther away impels technological advances to realize ever more sensitive detectors. Since 2019, one advanced technique, the injection of squeezed states of light is being used to improve the shot noise limit to the sensitivity of the Advanced LIGO detectors, at frequencies above 50 Hz. Below this frequency, quantum back action, in the form of radiation pressure induced motion∼ of the mirrors, degrades the sensitivity. To simultaneously reduce shot noise at high frequencies and quantum radiation pressure noise at low frequencies requires a quantum noise filter cavity with low optical losses to rotate the squeezed quadrature as a function of frequency. We report on the observation of frequency-dependent squeezed quadrature rotation with rotation frequency of 30 Hz, using a 16 m long filter cavity. A novel control scheme is developed for this frequency-dependent squeezed vacuum source, and the results presented here demonstrate that a low-loss filter cavity can achieve the squeezed quadrature rotation necessary for the next planned upgrade to Advanced LIGO, known as \A+." I. INTRODUCTION noise has been observed in the Advanced LIGO [6] and Virgo [7] detectors under current operating conditions, Quantum noise imposes a fundamental limitation and limits the level of squeezing which can be profitably on the precision of physical measurements. In used. gravitational-wave detectors such as Advanced LIGO [1], To avoid degradation in the low frequency sensitivity it manifests in two ways: shot noise, caused by quantum due to the quantum radiation pressure noise that results fluctuations in the arrival time of photons detected from higher levels of squeezing and/or increased laser at the interferometer output; and quantum radiation power in the interferometers, a technique known as pressure noise (QRPN), due to quantum fluctuations in \frequency-dependent squeezing" [8,9] is required [10, the photon flux impinging on the interferometer mirrors. 11]. In this work, we present a measurement of Both noises have a common origin|electromagnetic frequency-dependent squeezing from a system scalable vacuum states entering the open output port of the to Advanced LIGO's upcoming A+ upgrade. To achieve interferometer [2]. this, an optical cavity with low optical losses realized During its third observing run, Advanced LIGO has a squeezing rotation frequency nearly two orders of been detecting roughly one astrophysical event per week, magnitude lower than the previous demonstration [12]. compared to one per month in previous observing runs. We also introduce a novel optical sensing scheme that A significant factor in the sensitivity improvements that allows for controlling the squeezed vacuum source to has enabled this increased detection rate is the injection meet the stringent requirements of the Advanced LIGO of squeezed states of light into the output port of the detectors [13]. The importance of frequency-dependent Advanced LIGO detectors [3]. Squeezed state injection| squeezing for gravitational-wave detection cannot be or simply \squeezing"|has also been used in the overstated. A+ is the only planned upgrade for Advanced Advanced Virgo and GEO detectors [4,5]. The squeezed LIGO in the foreseeable future, and frequency-dependent states used redistribute quantum uncertainty to have a squeezing the only technology mature enough to provide arXiv:2003.13443v1 [astro-ph.IM] 26 Mar 2020 minimum in the phase quadrature, thus reducing shot broadband improvement in sensitivity. noise that dominates above 50 Hz. As a consequence of Concurrent with, and independent of, this work, a the Heisenberg uncertainty∼ principle, the increased noise similar experiment was carried out in Japan with a in the amplitude quadrature degrades the sensitivity of 300 m filter cavity, which demonstrates sub-shot-noise the interferometer at lower frequencies due to radiation performance below the squeezed state rotation frequency pressure that drives motion of the 40 kg mirrors of [14]. the interferometer. This quantum radiation pressure ∗ [email protected] y [email protected] 2 A) Squeezed 1064 nm Field B) Frequency Electronic Signal Dependent Interferometer 532 nm Field Squeezed Laser LIGO Filter Coherent Locking Field Vacuum Interferometer Cavity Rotation Resonant Locking Field 0Hz Vacuum Enclosure D) 40Hz Power Recycling arm cavity 220 80Hz MHz AOM3 120Hz Signal Recycling LIGO OPO CLF Homodyne pump RLF Future Interface Gen. to Interferometer Readout RLF: 209.3 MHz AOM2 Frequency (+) Independent SQZ Gen. OPO Squeezed CLF: Angle LO pump Vacuum Control C) 208.9 Source 16m Experiment MHz Measurement SQZ Spectrum λ/4 0Hz 200 AOM1 MHz (-) 40Hz SHG CLF(B) OPO SQZ Angle 80Hz 8.9 MHz Sensing 17.8 MHz Balanced Frequency Actuation CLF 120Hz Homodyne RLF Filter Cavity CLF RLF LO Readout Resonance (A) 9.3 MHz Squeezing Sensing Pump Laser RF Source RF with Freq. Control Piezo Phase Control Fiber In/Out Coupler Photodiode Faraday Isolator/Circulator FIG. 1. Schematic overview of the optical and electronic layout for the experiment. Panel A): The output of a 1064 nm laser is used to produce a 532 nm field via a second harmonic generator (SHG), a local oscillator (LO) for homodyne detection, and two frequency-shifted fields (CLF and RLF) for generating error signals to control the squeeze angle and the filter cavity detuning. The squeezing angle is sensed using the coherent locking field (CLF), and the filter cavity detuning is sensed by the resonant locking field (RLF). The 532 nm field is split into two components, one for generating squeezing as well as controlling the length of the OPO, and the other for controlling the length of the filter cavity. Panel B): frequency-independent squeezed vacuum generated by the OPO is injected into the filter cavity, and experiences frequency-dependent rotation upon reflection. panel C): the frequency-dependent squeezing is measured on a balanced homodyne detector. Panel D): how the filter cavity will integrate optically with the LIGO interferometer. II. FREQUENCY-DEPENDENT SQUEEZING injected squeezing [10, 15]. When squeezing is WITH A FILTER CAVITY injected into the interferometer without a filter cavity, as is routinely done in both Advanced LIGO [16] We produce frequency-dependent squeezing by reflect- and Advanced Virgo [4] during observing run 3, the ing a squeezed state from one or more optical cavities, optomechanical interaction between the amplitude of the known as “filter cavities"; a method first suggested by optical field and the momentum of the suspended optics Kimble et al. in 2001 [8]. When the filter cavity will shear (both squeeze and rotate) the injected state at resonance is \detuned" with an offset relative to the low frequencies. When injecting frequency-independent carrier frequency of the squeezed state, it applies a squeezing, this rotates part of the antisqueezed vacuum differential phase shift to the upper and lower sidebands noise into the readout quadrature [17]. The A+ filter of the squeezed optical field. Since the squeezed cavity is designed to apply a compensating rotation to quadrature angle at a given sideband frequency is the squeezed state before it enters the interferometer, determined by the relative phase between the upper and to cancel the rotation due to the optomechanical lower sidebands, the filter cavity serves to rotate the interaction. squeezed state for sideband frequencies that lie within The power circulating in the interferometer arm the cavity linewidth (see Appendix A.3 of [9] for details). cavities determines the strength of the optomechanical For Advanced LIGO, a single filter cavity is needed interaction and thus the frequency of the squeeze angle to imprint the required frequency-dependence on the rotation required to compensate it. With up to 800 kW of circulating power anticipated for future observation runs, 3 the filter cavity must have a bandwidth of approximately 50 Hz, equivalent to a storage time of 3 ms. TABLE I. Experimentally determined parameters of the frequency-dependent squeezed vacuum source. Entries In general, for a low-loss optical resonator of length L marked by an asterisk were determined most accurately and input mirror transmission Tin, the cavity half-width- through fitting to the data. In all cases fitting produced half-maximum-power bandwidth γ=2π, in units of Hz, is values in agreement with independent measurements and their uncertainties. γ T + Λ c c = in ; (1) Parameter Value 2π 4π 2L ≈ 4L F Filter cavity length 16:0611(2) m where Λ is the round trip loss in the cavity and is the Filter cavity storage time 2:8(1) ms finesse of the cavity. F Filter cavity decoherence time 5:7(3) ms OPO nonlinear gain 4:5(1) From the approximation on the right, it follows that OPO escape efficiency 98(1) % in order to achieve a bandwidth as narrow as 50 Hz, the Propagation loss∗ 17(1) % filter cavity must either be very long or have a very high Homodyne visibility 91:9(4) % finesse (i.e. very low optical loss). For example, a 300 m Photodiode quantum efficiency 99(1) % long filter cavity like the one planned for A+ [13] (and Filter cavity round-trip loss 19(1) ppm the one operating in Japan [18][14]) can achieve a 50 Hz Freq.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    6 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us