
www.ancorp.com VACU-SHIELD TRAPS AND FILTERS DRY-ICE COLD TRAP The Dry Ice Cold Trap mixes dry ice and isopropyl alcohol to pro- duce an extremely cold slurry that traps condensible vapors in low vacuum or during initial evacua- tion of a vacuum system. CONTENTS 1. Product Features.................................................................................................................................2 2. The Role of Temperature...............................................................................................................2 3. Connection Options...........................................................................................................................3 4. Replacement Parts............................................................................................................................4 5. Comparison of Media Compatability....................................................................................5 LN2 Cold Trap LN2 Cold Trap Product Features Connection Options Dry-Ice Traps are extremely effective for Dry-Ice Cold Traps feature two connection options: Tube Port and and ISO-QF Connections. applications whose base pressure is 1 milliTorr Trapping Media: Stainless steel well or higher. D Pump protection from water and condensible vapor TUBE PORT CONNECTIONS They utilize a process called cryopumping, – Port Terminations : Tube End Trapping system: Mixture of dry-ice and alcohol to trap which is where molecules, in kinetic or transi- condensible vapors in low vacuum or during initial – Electropolished wetted surfaces: facilities clean- tionary flow, come into brief random contact evacuation of your vacuum system. ing and servicing, promotes system cleanliness, with the trap's cold surface. During each col- Electropolished body: eases cleaning, deflects heat and and deflects heat to minimize frequency pf media lision, the molecule gives up part of it's kinet- reduces iron concentration on trap surfaces; increases change-outs. corrosion resistance C ic energy to the cold wall. Eventually, the – Clear, loose fitting lid: See through design allows a 3.50 molecule becomes stuck to the cold surface. Clear, loose fitting lid: see through design allows quick quick check on condition of cold media. Loose fitting B checks on condition of cold media. Provides a sim- lid provides a simple vent for sublimating carbon The trap holds 3 quarts of dry-ice slurry (dry- ple vent for sublimating carbon dioxide and prevents dioxide and prevents "unsafe" pressure build up. "unsafe" pressure build up ice and alcohol). Holding time is approx- – Clear view ring: See through design allows a quick 2.75 imately 20 hours depending on vacuum Clear view ring: see through design allows a quick visual check on condition of cold surface. throughput. visual check on condition of cold surface. Visually determine cold surface needs to be cleaned due to ice – Media: Use dry ice and isopropanol slurry for maxi- bridges and pump lubricant deposition A The stainless steel well is visible during oper- mum cold trapping effect ation and defrost/clean up is easily accom- Multiple connection options: ISO-QF, hose end, and REFERENCE TUBE END TRAPPING HOUSING BODY HEIGHT OVERALL OVERALL others upon request PART # plished. ID CONNECTION MEDIA DIAMETER A B HEIGHT C WIDTH D 7500420 VSDI-800-050 0.50 Dry Ice 7.88 9.00 10.50 10.70 7500421 VSDI-800-075 0.75 Dry Ice 7.88 9.00 10.50 10.70 THE ROLE OF TEMPERATURE ISO-QF CONNECTIONS D – Port Terminations : ISO-QF Flanges The temperature of the dry-ice/isopropanol slurry (-77o C) determines the temperature of the cold – Electropolished wetted surfaces: facilities cleaning and wall. The temperature of the cold wall determines the ambient temperature and, ultimately, the servicing, promotes system cleanliness, and deflects achievable base pressure. The effective base pressure achievable by a cold trap is determined by the heat to minimize frequency pf media change-outs. highest vapor pressure of the condensable gases being pumped. – Clear, loose fitting lid: See through design allows a C quick check on condition of cold media. Loose fitting B lid provides a simple vent for sublimating carbon diox- 3.50 Liquid Nitrogen Dry Ice ide and prevents "unsafe" pressure build up. – Clear view ring: See through design allows a quick Temperature 77K (-196o C) 195K (-78oC) visual check on condition of cold surface. 2.75 – Media: Use dry ice and isopropanol slurry for maxi- Vapor Pressure of Water at mum cold trapping effect 10-12 Torr 10-3 Torr A Temperature (Torr) REFERENCE TUBE END TRAPPING HOUSING BODY HEIGHT OVERALL OVERALL PART # ID CONNECTION MEDIA DIAMETER A B HEIGHT C WIDTH D Note: Vapor pressures provided are nominal values only. Exact values can be found in the Handbook of Chemistry and Physics. 7500422 VSDI-800-QF16 QF16 Dry Ice 7.88 9.00 10.50 11.00 7500423 VSDI-800-QF25 QF25 Dry Ice 7.88 9.00 10.50 11.00 7500424 VSDI-800-QF40 QF40 Dry Ice 7.88 9.00 10.50 11.00 22 [email protected]@ancorp.com •• 1-800-FLANGE11-800-FLANGE1 (352-6431)(352-6431) •• www.ancorp.comwww.ancorp.com [email protected] • 1-800-FLANGE1 (352-6431) • www.ancorp.com 3 LN2 Cold Trap Replacement Media for Dry-Ice Traps ANCORP offers a wide selection of replacement media including Buna, Viton, and EPDM seal kits, acrylic viewing rings, acrylic lids, DEWAR plug kits, and stainless steel wells. Seal Kit REFERENCE PART # DESCRIPTION ID 7510400 VSDI-800-BSK Replacement Seal Kit - Buna 7510401 VSDI-800-VSK Replacement Seal Kit - Viton Acrylic Lid 8751421 VSDI-800-ESK Replacement Seal Kit - EPDM 7510410 VSDI-800-VR Replacement Acrylic Viewing Ring Replacement 7510403 VSDI-800-LA Replacement Acrylic Lid Stainless Steel Well 7510476 VSC-DPK-L DEWAR Plug Kit for - Size 5.0 Liter 7510415 VSDI-800-W Replacement Stainless Steel Well COMPARISON OF MEDIA COMPATIBILITY Compatible media varies among different trap types. Moisture and condensable vapors are the two media compatible with the LN2 Cold Trap. Activated Activated Caustic Soda Molecular Sieve Cryo-traps (VSCI Media/Trap Alumina (VSRC) Charcoal (VSRC) (VVRI) (Zeolite) (VSMI) & VSDI) Acids X X Organics X Moisture X X X Polar compounds, Condensable Other Heavy metals CO CO Lewis acids 2 2 vapors For any further questions regarding LN2 cold traps, contact an ANCORP representative by email at [email protected] or by telephone at 1-800-FLANGE1. 44 [email protected]@ancorp.com •• 1-800-FLANGE11-800-FLANGE1 (352-6431)(352-6431) •• www.ancorp.comwww.ancorp.com.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages3 Page
-
File Size-