Fire Department City of New York Study Material For

Fire Department City of New York Study Material For

Rev: 7-9-19 (update NOE and sprinkler heads) FIRE DEPARTMENT ● CITY OF NEW YORK STUDY MATERIAL FOR THE EXAMINATION FOR THE CERTIFICATE OF FITNESS FOR SUPERVISION OF SPRINKLER SYSTEMS (CITYWIDE) S-12 SUPERVISION OF FOAM-WATER SPRINKLER SYSTEMS (CITYWIDE) S-15 This book is provided to the public for free by the FDNY. NEW APPLICANTS (STARTING 6-6-16): S-12 FOR FACILITY WITHOUT FOAM-WATER SPRINKLER SYSTEMS S-15 FOR FACILITY WITH FOAM-WATER SPRINKLER SYSTEMS ▼ S-12 SUPERVISION OF SPRINKLER SYSTEMS (CITYWIDE) 75 QUESTION EXAM; CHAPTER 1 TO CHAPTER 16 OF THIS STUDY MATERIAL S-15 SUPERVISION OF FOAM-WATER SPRINKLER SYSTEMS (CITYWIDE) 100 QUESTION EXAM; CHAPTER 1 TO CHAPTER 19 OF THIS STUDY MATERIAL (WHOLE BOOKLET) CONSISTS OF THE CITYWIDE SPRINKLER SYSTEM QUESTIONS AND FOAM-WATER SPRINKLER SYSTEM QUESTIONS. T-15 FOAM-WATER SPRINKLER SYSTEMS ONLY 25 QUESTION EXAM; CHAPTER 1 TO CHAPTER 19 OF THIS STUDY MATERIAL (MAJORITY OF QUESTIONS ON THIS EXAM ARE COVERED BY CHAPTER 17 TO CHAPTER 19) EXISTING S-12 C of F IS RENEWABLE AND CAN BE UPGRADED TO S-15 BY TAKING T-15 EXAM. Issued 11/29/10 © New York City Fire Department - All rights reserved ® Official use (Cpgs:36-40,102-112,120-129) 2 CONTENTS NOTICE OF EXAMINATION ........................................................................................................................... 4 1. INTRODUCTION ...................................................................................................................................... 11 1.1 SPRINKLER AND/OR STANDPIPE SYSTEM MAINTENANCE AND INSPECTIONS ................................................ 11 2. RESPONSIBILITY OF THE BUILDING OWNER .............................................................................. 12 3. OUT OF SERVICE SYSTEMS (OOS) .................................................................................................... 12 4. GENERAL PROCEDURE FOR RECORD KEEPING, IMPAIRMENTS AND SAFETY ............... 17 5. INDIVIDUALS AUTHORIZED TO PERFORM TASKS AS SPECIFIED IN THE NEW YORK CITY FIRE CODE ............................................................................................................................................. 18 6. DEFINITIONS ............................................................................................................................................ 19 7. SYSTEM TYPES ........................................................................................................................................ 25 7.1 AUTOMATIC WET SPRINKLER SYSTEMS .................................................................................................................... 25 7.2 AUTOMATIC DRY SPRINKLER SYSTEMS .................................................................................................................... 27 7.3 PREACTION SPRINKLER SYSTEMS ............................................................................................................................... 29 7.4 DELUGE SPRINKLER SYSTEMS ...................................................................................................................................... 30 7.5 NON-AUTOMATIC DRY SPRINKLER SYSTEMS .......................................................................................................... 30 7.6 GARBAGE COMPACTOR SPRINKLER SYSTEMS ......................................................................................................... 30 8. WATER SUPPLIES FOR SPRINKLER SYSTEMS ............................................................................. 32 8.1 CONTROL VALVES ............................................................................................................................................................ 32 8.2 SPRINKLER SYSTEM CONTROL VALVE SIGNAGE .................................................................................................... 33 8.3 FIRE DEPARTMENT CONNECTIONS .............................................................................................................................. 33 8.4 Gravity Tanks ........................................................................................................................................................................ 34 8.5 Pressure Tanks ....................................................................................................................................................................... 34 8.6 Fire Pumps ............................................................................................................................................................................. 35 9. WATER-FLOW ALARMS AND SPRINKLER SYSTEM SUPERVISION ....................................... 35 9.1 FUNCTIONS OF ALARMS AND SUPERVISORY SIGNALS .......................................................................................... 35 9.2 DEVICES AND EQUIPMENT SUPERVISED .................................................................................................................... 35 10. SYSTEM COMPONENTS ..................................................................................................................... 36 10.1 SPRINKLER HEADS ........................................................................................................................................................... 36 10.1.1 Four Types of Sprinkler Heads .......................................................................................................................................... 37 10.1.2 Spray Pattern of Sprinkler Heads ..................................................................................................................................... 40 10.1.3 Standard Response and Quick Response Heads ......................................................................................................... 40 10.1.4 Systems Using Large Drop Sprinkler Heads .................................................................................................................. 41 10.2 TEMPERATURE RATINGS CLASSIFICATIONS AND COLOR CODING .................................................................... 42 10.3 BUILD-UP OF FOREIGN MATERIAL ON SPRINKLERS ............................................................................................... 42 10.4 SPARE SPRINKLER HEADS .............................................................................................................................................. 43 10.5 PRESSURE TANKS ............................................................................................................................................................. 43 10.6 STANDARD PRESSURE TANK ......................................................................................................................................... 44 10.7 GRAVITY TANKS ............................................................................................................................................................... 45 10.8 FIRE PUMPS ........................................................................................................................................................................ 46 11. HANGING, BRACING AND RESTRAINT OF SPRINKLER SYSTEM PIPING ......................... 49 11.1 A BRIEF OVERVIEW OF PIPING AND SUPPORT FUNDAMENTALS ........................................................................ 54 This book is provided to the public for free by the FDNY. 2 3 12. INSPECTION, TESTING AND MAINTENANCE FREQUENCIES ............................................... 58 12.1 INSPECTION AND MAINTENANCE OF PRESSURE TANKS ....................................................................................... 58 12.2 INSPECTION AND MAINTENANCE OF THE GRAVITY TANK .................................................................................. 58 12.3 PUMP INSPECTION AND MAINTENANCE .................................................................................................................... 58 12.4 COMMON DEFICIENCIES ................................................................................................................................................. 59 12.5 A COMPLETE SUMMARY OF TASKS OF INSPECTION, MAINTENANCE & TESTING .......................................... 61 12.5.1 INSPECTION ............................................................................................................................................................................ 61 A. Sprinkler Systems: .................................................................................................................................................................... 61 B. Fire, Booster and Special Service Pumps: ......................................................................................................................... 62 C. Water Storage Tank: ................................................................................................................................................................. 63 D. Valve and Valve Component: ................................................................................................................................................. 64 12.5.2 TESTING ................................................................................................................................................................................... 68 A. SPRINKLER SYSTEMS: ...........................................................................................................................................................

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    130 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us