Installation/Service Meter | Oneexpert DSP (ONX-220)

Installation/Service Meter | Oneexpert DSP (ONX-220)

VIAVI Solutions Data Sheet VIAVI OneExpert DSP (ONX-220) Installation/service meter with ONX DNA, making it unequalled in speed, simplicity and value. When home network quality is unreliable, customers become dissatisfied and are more likely to churn. At Key Features the same time technical complexity is increasing, but y AutoChannel™ instantaneous channel lineup technician skill and experience at the installation service detection eliminates need for lineup editing, updating and deploying tier is typically minimal. It’s never been more important y to have quick, effective troubleshooting tools that enable OneCheck comprehensive mistake-proof automated tests, including: ingress, downstream techs to quickly and efficiently verify performance as channels and DOCSIS carriers at three advertised. The ONX-220 is fast, complete, and follows up demarcation points (Tap, GB, CPE) testing with simple cloud data storage to enable real- y DOCSISCheck real-time analysis and powerful time close-out and reporting. DOCSIS carrier and data service troubleshooting; upstream and/or downstream Benefits y ChannelCheck real-time analysis and powerful downstream QAM, OFDM, and Analog carriers y Fastest and most comprehensive tool for verifying troubleshooting high speed DOCSIS service activation and performance y DQI (Digital Quality Index) focuses on raw information condition on the physical path, y Rugged build quality, workmanship, and reliability immediately detects intermittent and sustained expected from VIAVI and our years of measurement issues within the stream experience y Integrated Bluetooth connectivity enables leveraging mobile device GPS and multi-media y Technicians now have access to a rugged, precise capabilities with VIAVI Android/iOS Mobile measurement instrument at a budget minded price Tech App y Ready for high-speed Gigabit Ethernet and y Best balance of features, performance, and DOCSIS and WiFi* service testing, unavailable cost – designed to meet the with other low-cost competing products budgets of installers y OneCheck Fiber consolidates tests with P5000i and contractors and FiberChek Pro optical inspection scopes, SmartOTDR optical time domain reflectometer and MP60/80 optical power meter * Network service testing is included only on Plus and Pro models. Data Sheet Specifications Frequency Analog Channel Measurement Range Diplexer Upstream Downstream Video and audio levels (dual) Standards NTSC , PAL Min −50 dBmV (single channel) Automatically 42/85 5 - 42 MHz 54 - 1,004 detectable Switching and 5 - 85 MHz and 108 signal Diplexer MHz - 1,218 MHz Level accuracy ±1.5 dB from −20 dBmV to +15 dBmV 65/204 5 - 65 MHz 83 - 1,218 MHz typical at 25°C; ±2.0 dB, −10°C to and 5 - 204 and 258 MHz +50°C MHz - 1,218 MHz RBW 300 kHz Accuracy ±10 ppm typical @25°C Carrier to Noise Downstream Analysis Channel types NTSC , PAL, non-scrambled AutoChannel Auto detection of channel parameters Range 30 to 51 dB plan builder (analog/digital, symbols, QAM) (NTSC, 4 MHz measurement Max input 38 dBmV total integrated power bandwidth) power Required 0 to +15 dBmV with 77 analog channels Return loss >6 dB input level present, maximum ±15 dB tilt 50 to Upstream Analysis 1,000 MHz Ingress 5.0 – 204 MHz Accuracy ±2.0 dB within specified measurement spectrum range scan ≤ 600 MHz Sensitivity −38 dBmV Downstream Digital Channel Analysis RBW 100 kHz Calibrated -20 dBmV to +15 dBmV Min −38 dBmV power levels detectable Level accuracy ±1.5 dB from -20 dBmV to +15 dBmV level typical at 25°C; ±2.0 dB, -10°C to upstream +50°C Accuracy ±2 dB typical at 25°C Modulation(s) 64, 128, and 256 QAM, OFDM Return loss >6 dB Annex A: 5.057 to 6.952 MSPS Annex B: 5.057 for 64 QAM and 5.361 MSPS for 256 QAM Annex C: 5.274 MSPS for 64 QAM and 5.361 MSPS for 256 QAM Full span MER Ingress under carrier — full span ingress noise trace Group delay and in-channel frequency response (ICFR) Digital quality index (DQI) over time Errored/severely errored seconds Level, measured symbol rate, carrier frequency, modulation, interleaver depth (data log only) 2 ONX-220 Specifications Continued OFDM Signal Performance Metrics Displayed DOCSIS Results OFDM Channels 24 - 192 MHz wide - up to 3 Top level Number of bonded channels, min active OFDM channels receive level, max BER (pre-FEC), Level — max, min, relative to a 6 MHz carrier per min and max MER, max transmit average, standard CableLabs© level, max ICFR (in-channel deviation frequency response) MER — max, 16 to 44 dB Details Downstream SC-QAM (over time min, average, charts: level, MER, BER, DQI), standard deviation, Upstream (charts: transmit over percentile time, upstream ICFR, upstream MER channel band max, min, avg across entire OFDM EQ taps graph carrier Service tests Registration, Throughput, Ping/ Noise max Traceroute, Packet Quality; cable modem pass-through Echo dBc OFDM OFDM selected in scan, number ICFR in-carrier frequency response (dB) of subcarriers, PLC lock status, Spectrum/IUC spectrum display, including carrier frequency, level, and MER, CWE and ingress under carrier (corr, uncorr); OFDM channel(s) - OFDM Profile Analysis Level variation (max, min, avg), Profiles A, B, C, D, NCP, and PLC MER variation (max, min, avg), (more profiles as implemented) ICFR, profile analysis (locked, CWE Lock status, codeword errors corr, CWE uncorr) (corrected and uncorrected) Downstream DOCSIS Testing Frequency range 42/65/85/204 to 1,218 MHz Supports DOCSIS 3.1 bonding up to 32 SC-QAM + 2 (dependent on currently active OFDM downstream channels, 8 SC-QAM + 2 OFDMA diplexer frequency) upstream channels Upstream Compliant with CableLabs® specifications for DOCSIS Frequency range 5 to 204 MHz (dependent 3.1 on currently active diplexer Compliant with CableLabs® specifications for DOCSIS frequency) 3.0 (32x8 bonding) OFDMA channels ≥2, per DOCSIS specification Transmit level +61 to +48 dBmV depending on range (max) modulation format and number of bonded carriers, per DOCSIS specification SC-QAM channels up to 8 per DOCSIS specification 3 ONX-220 Specifications Continued MER Input/Outputs Specified range1 21 to 40 dB, 64 QAM; 28 to 40 dB, RF F connector replaceable (with input level 256 QAM; 16 to 44 dB OFDM Charge Port USB-C -5 to +15 dBmV) USB Port USB 3.0 (Type A) Max displayable 50 dB Ethernet RJ45 10/100/1000T range Power USB-C Resolution 0.1 dB Remote Access/Connectivity Accuracy ±2 dB typical at 25°C VNC accessible via IP address Minimum lock level −15 dBmV HTTPS file access via IP address BER — Down to 1E-9 (pre and post FEC) Mobile Tech application via Bluetooth ChannelCheck Smart Access Anywhere (option) via IP network or the and DOCSISCheck Internet, which can be via Ethernet, WiFi or mobile mode hot-spot BER — OneCheck Down to 1E-8 (pre and post FEC) Battery mode default; 1E-9 user selectable Field replaceable 48 WHr 7.4 V, 6-cell LiIon Interleaver depth 128, 8 max Typical battery life 8 hr typical usage Display/Interface/Usability Battery charge 2 Hrs (90%) 3 Hrs 100% High-brightness 5 inch diagonal time (included USB-C charger) color LCD (800 x 480) StrataSync Reporting Capability Touch screen Capacitive Session based (job/work order) file saving of results gathered at TAP, GB, and CPE Boot time Approximately 20 sec Measurement screen capture save and recall Environmental StrataSync Core Asset and data management For indoor/outdoor IP 54 light rain (0.5 in/hr; use 1.27 cm/hr) StrataSync Plus Optional extended data management Pollution 2° (6 years) Drop 1 m (3.3 ft) onto concrete Warranty Temp range Operating −10 to 50°C Instrument 1-year warranty (See http://www. (14 to 122°F) viavisolutions.com/services-and- Storage −20 to 60°C support/support/warranty-terms- temp (-4 to 140°F) and-conditions for warranty Humidity 10 – 90% RH non-condensing details) RF immunity 8.5 V/m (for CATV measurements) Accessories and One-year warranty Maximum altitude 4000 m (13,123 ft) battery 1. MER range declines as input levels decrease. Expected MER range at MIN LOCK level of –15 dBmV 4 ONX-220 Specifications Continued Dimensions Optical Fiber Scope Width 5.27 in (133.88 mm) USB optical fiber P5000i Height 9.96 in (252.89 mm) scope Depth 2.23 in (57.33 mm) Results for zone Pass/fail Weight defects Device (without 3.10 lb (1.41 kg) Results for zone Pass/fail protective case) scratches Protective case and 1.10 lb (0.50 kg) Low mag field-of- Horizontal 740 μm, vertical 550 μm shoulder strap view (FOV) WiFi (Plus & Pro Models Only) High mag field-of- Horizontal 370 μm, vertical 275 μm view (FOV) Test interface 802.11 a/b/g/n/ac (2.4/5 GHz) Particle size <1 μm Tests WiFi scan detection Antennas 3x3 Power source USB port Scan results SSID (secure set identification); Setting for profile, tip, focus meter, button action Channel; Security setting; Power level; MAC address Actions for live mode, test mode, high magnification Scan modes Channel graph; Probe model, serial, firmware Time graph Standard Accessories Fiber Test Protective case with hand strap and detachable Optical Fiber Power Meter shoulder strap USB optical power MP-60, MP-80 AC power supply with country-specific adaptor plugs meter (USA, UK, Euro, Australia, China) Measurement units dBm, mW, dB Quick start guide Connector input Universal 2.5 and 1.25 mm StrataSync Core support connectors Power source USB port 5 ONX-220 Ordering Information Description Part Number SW Pkg Dual Diplexer Model Base 42/85 MHz ONX-220-42-85-D31-BASE 65/204 MHz ONX-220-65-204-D31-BASE Plus 42/85 MHz ONX-220-42-85-D31-PLUS 65/204 MHz ONX-220-65-204-D31-PLUS Pro 42/85 MHz ONX-220-42-85-D31-PRO 65/204 MHz ONX-220-65-204-D31-PRO

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    10 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us