Wada et al. BMC Surg (2021) 21:219 https://doi.org/10.1186/s12893-021-01218-y CASE REPORT Open Access Combined brain and thoracic trauma surgery in a hybrid emergency room system: a case report Daiki Wada1*, Koichi Hayakawa2, Fukuki Saito1, Kazuhisa Yoshiya1, Yasushi Nakamori1 and Yasuyuki Kuwagata3 Abstract Background: A novel trauma workfow system called the hybrid emergency room (Hybrid ER), which combines a sliding CT scanner system with interventional radiology features (IVR-CT), was initially instituted in our emergency department in 2011. Use of the Hybrid ER enables CT diagnosis and emergency therapeutic interventions with- out transferring the patient to another room. We describe an illustrative case of severe multiple blunt trauma that included injuries to the brain and torso to highlight the ability to perform multiple procedures in the Hybrid ER. Case presentation: A 46-year-old man sustained multiple injuries after falling from height. An early CT scan per- formed in the Hybrid ER revealed grade IIIa thoracic aortic injury, left lung contusion, and right subdural haematoma and subarachnoid haemorrhage. Without relocating the patient, all defnitive procedures, including trepanation, total pneumonectomy, and thoracic endovascular aneurysm repair were performed in the Hybrid ER. At 5.72 h after defni- tive surgery was begun, the patient was transferred to the intensive care unit. Conclusions: The Hybrid ER has the potential to facilitate the performance of multiple defnitive procedures in com- bination to treat severe multiple blunt trauma including injuries to the brain and torso. Emergency departments with more than one resuscitation room would beneft from a Hybrid ER to treat complex emergency cases. Keywords: Hybrid emergency room (Hybrid ER), Thoracic endovascular aneurysm repair (TEVAR), Intracranial pressure (ICP), Cerebral perfusion pressure, Traumatic brain injury Background CT suite, radiology department, or the operating room. A novel trauma workfow system comprising a sliding It was previously reported in a retrospective cohort study CT scanner system with interventional radiology features that trauma workfow in the Hybrid ER may improve (IVR-CT), which we call the Hybrid emergency room survival in patients with severe trauma [2]. Presently, (Hybrid ER), was installed in our hospital’s emergency 11 trauma centres have installed a Hybrid ER in Japan department (Fig. 1) [1]. Use of the Hybrid ER enables [3]. Hybrid ER use reportedly has also allowed safe and emergency procedures, including damage control sur- prompt initiation of other procedures such as extracor- gery and endovascular intervention after CT diagnosis, poreal membrane oxygenation [4]. to be performed without transferring the patient to the Preventable trauma deaths are defned as those in which signifcant delays occur before exsanguinating haemorrhage is controlled [5]. Terapeutic procedures *Correspondence: [email protected] and diagnostic evaluation must be concomitantly per- 1 Department of Emergency and Critical Care Medicine, Kansai Medical University General Medical Center, 10-15 Fumizono-cho, Moriguchi, formed by a multidisciplinary team [6]. Time is crucial in Osaka 570-8507, Japan the successful early management of the multiple trauma Full list of author information is available at the end of the article patient [7]. Te Hybrid ER has the potential to resolve the © The Author(s) 2021. This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://crea- tivecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdo- main/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. Wada et al. BMC Surg (2021) 21:219 Page 2 of 6 was available. 6 min after admission, a CT examina- tion was begun using the sliding CT scanner with the patient on the same trauma table without relocating him (Fig. 2a). CT revealed a grade IIIa thoracic aortic injury with pseudoaneurysm, left lung contusion with contrast agent leakage, left multiple rib fractures and haemopneumothorax, and right SDH and subarach- noid haemorrhage (SAH) with brain swelling (Fig. 3). Generally, when treating a severely traumatised patient, torso haemostasis is given priority over the treatment of brain injury. However, the CT fndings in this patient indicated that treatment for brain injury had the high- Fig. 1 Photograph showing our IVR-CT system in the Hybrid ER est priority. At 38 min after admission, the SDH was (Aquilion PRIME, TSX-303B; Toshiba Medical Systems Corp., Tochigi, punctured and an ICP of approximately 10 mmHg was Japan). All life-saving procedures including airway management, measured (Fig. 2b). Following this surgery, the amount emergency surgery, and transarterial embolization can be performed of air and bloody pleural efusion had clearly increased. on the table without relocating the patient. a Sliding CT scanner with the two rows of rails on the foor, b CT examination and In addition to CT fndings of contrast agent leakage in intervention table, c moveable C-arm, d 56-inch monitor screen, the left lung contusion, and as bloody sputum was suc- e ultrasonography equipment, and f mechanical ventilator. Unlike tioned from the tracheal tube, we determined that a left the usual CT scanner, after the patient is positioned on the CT lung injury was likely the primary source of bleeding. examination and intervention table, the CT scanner moves to the Tus, one minute after trepanation for SDH was com- table on rails with the table fxed. We use the room next to the Hybrid ER for surgical instrument storage and bring only what we need pleted, left thoracotomy was performed, again without for the surgery into the Hybrid ER. The ventilator is located on the relocating the patient (Fig. 2c). Te upper left lobe of foot side of the trauma table. The blood refrigerator is located in the the lung was resected as this was the main source of intensive care unit near the Hybrid ER. When an anaesthesiologist bleeding. However, bleeding from the hilum persisted, performs inhalation anaesthesia, the anaesthesia machine is located which led to the performance of TEVAR for a probable near the head side of the trauma table. Because the sliding CT scanner is moved to the adjacent CT suite after the CT scan, adequate aortic injury (Fig. 2d). Sixteen minutes after the thor- space is available near the head side of the trauma table acotomy was completed, TEVAR was initiated, with access for the delivery device obtained via the right femoral artery. A grade IIIa thoracic pseudoaneurysm time delay to CT scanning and defnitive therapy. Here, of 13 mm in diameter was located at the isthmus of the this is an illustrative case of severe multiple blunt trauma aorta. As the left subclavian artery was near the isthmus treated by a combination of total pneumonectomy, tho- injury, the stent graft was deployed to extend between racic endovascular aneurysm repair (TEVAR), and the aortic arch and descending aorta, which covered trepanation for subdural haematoma (SDH) along with the left subclavian artery, to obtain an adequate proxi- intracranial pressure (ICP) monitoring in the Hybrid ER. mal landing zone. Te proximal end of the stent graft was positioned 6 mm from the left carotid artery, which Case presentation was preserved. Following these procedures, which the A 46-year-old man sustained multiple injuries after patient tolerated well, another CT scan was performed falling from height while working. He was previously without relocating the patient and showed no signs of healthy and without comorbidities. An emergency phy- worsening brain injury. Because the amount of bloody sician intubated him on the scene due to consciousness pleural efusion continued to increase, repeat left thor- disorder. Te patient’s vital signs on arrival were Glas- acotomy revealed bleeding from the left lower lobe, gow Coma Scale, 3; blood pressure, 93/85 mmHg; pulse which was subsequently resected. Tirty units each of rate, 156/min; respiratory rate, 22/min; and pulse oxi- whole blood and fresh frozen plasma and 10 units of platelets were transfused. At 5.72 h after initiation of metry of 99% at a FIO2 of 1.0 while intubated. Physical examination revealed subcutaneous emphysema over the defnitive surgeries and completion of all proce- the left chest. A chest tube was inserted for left tension dures in the Hybrid ER, the patient was transferred to pneumothorax, and a large amount of air and bloody the intensive care unit. pleural efusion was drained. Tereafter, his blood pres- Decompressive craniectomy on postoperative day 2 sure improved to 102/87 mmHg, but his pulse rate was and decompressive brain resection on postoperative day still over 150/min. Although the patient was not hemo- 3 were performed for refractory intracranial hyperten- dynamically stable, the CT scanner in the Hybrid ER sion. Te patient’s Injury Severity Score was 54, Revised Wada et al. BMC Surg (2021) 21:219 Page 3 of 6 a c 21min 1min 16min 14min Chest tube CT trepanaon thoracotomy TEVAR CT thoracotomy ICU 0 6 38 100 154 261 277 343 (min) b d Fig. 2 Timeline indicating the time of initiation of CT scanning and emergency procedures, including damage control surgery and endovascular intervention, in the Hybrid ER.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages6 Page
-
File Size-