REPLACE WITH USE CABLE WITH BATTERY CLIPS 15 MEG 200W R25 (CURRENT-LIMITING TO JUMPER B- SUPPLY TO FLOATING NICHROME COIL RESISTOR 75 DECK CHASSIS 24kW RESISTOR) REMOVE 150kV BUSHING BEAM VOLTAGE FROM FROM CB21 FROM CB22 CAPACITOR BANK B- BUS (DWG 430-106, P3) (DWG 430-106, P3) HV METERING TOWER HV COMPONENTRY BETWEEN CORONA RINGS ON TOP OF CAP. BANK INSIDE MODULATOR TANK L9 T23 AUX 3.4 uH T25 AUX LOWER CORONA RING MODULATOR 120V @ 6.9A 120V @ 6.9A -55kV FROM TAP ON RECTIFIER STACK * (DWG. 430_112) T23 T25 R86 ISO. 110kVDC -110kV FROM RECTIFIER STACK* 10K 4kW R84 * SEE DWG 430BLOK2.ECW CW C87: 11.4uF 8.6V @ 100A 8.6V @ 100A S76/1 100 FLOATING DECK OPTICAL FIBER PULSE 10kV UPPER400W CORONA RING T24 T28 BUFFER DECK OPTICAL FIBER 32V @ 25A NC NC 32V @ 25A R52 100k 800W 120VAC FROM K48B E18 V25 (4 x 100k IN (DWG. 430_106, p4) V25 15KV KLYSTRON B SERIES/PARALLEL) KLYSTRON A R4 LITTON L3403 25 120VAC FROM K48C LITTON L3403 300 M, 300W 200W R53 R47 (DWG. 430_106, p4) (R48,49,50,& 51) 10M 1k 200W C36 DISCONNECT 0.7 uF 55kV MODULATOR OVERCURRENT EARTH EARTH LATCHING RELAY GROUND GROUND ZENER TOWER K80 "KLY B COLLECTOR CURRENT" TO CONSOLE SCOPE CR5-CR9 C37-C41 R55 RG17u ANODE WIRES RUN CR9-CR13 C42-C46 150M 75 kV ACROSS FLOOR TO KLYSTRON VAULT TO KLYSTRON CR14-CR18 C47-C51 TO "BEAM VOLTAGE" SET COIL 100W BUSHING CATHODE (VIA R25), CR19-CR23 C52-C56 CONSOLE METER PROTECTION CIRCUIT - SHORTING BARS CROWBAR, CR24-CR29 C57-C61 RESET COIL R11 BODY CURRENT R22,R23 & HV METERING 0.16 METER SHUNT TOWER CR30-CR34 C62-C66 EACH 22k, 2W C88 R85 126W RG62 TO CONSOLE SCOPE SHORTING BARS CR34-CR39 C67-C71 E17 22K E13 1uF 2W R18 C28 C28/1 C29/1 1.5KV CR40-CR44 C72-C76 1uF 1uF .01uF R19 R93 100V 2.5 400V 4kV 600V CAPACITOR BANK CR45-CR49 C77-C81 400K 480W TO "KLY B COLLECTOR BLEEDER TOWER CR50-CR54 K80 CURRENT" 800W B- BUS (FULL HIGH VOLTAGE) C82-C86 R20 TO CROWBAR R21 TO MODULATOR VOLTMETER CONSOLE METER 50 CAPS FROM K57 (RESET) 5mV @ 5A PART B 50 ZENERS DWG J349C106 0.1uF, 600V EACH 50M 200Z K40A K39A R38 3.2M R1-1 R1-2 R1-3 R1-248 CROWBAR (200V EACH) K80 S79/1 TO INTERLOCK CHAIN R24 TO "BEAM CURRENT" CONSOLE METER R3-4 R3-3-B (32 x 100k) 1K .005 OHM 32 x 100K 150W "PULSE LENGTH" TO CROWBAR 32 x 100K @ 200W R56 @ 200W R39 R46 (DWG. 430_102) 240k K40B R90 3.2M 525k, R41 R89 (16 x 15k, 200W) 3120 (32 x 100k) C1-1 C1-2 C1-3 C1-248 7kW 1 uF 0.67 OHM, 1kW 6400 W 3120 0.15uF REMOVE 6400 W 120kV PULSECW METER SHUNT FRAME ON FLOOR AT END OF CAP BANK RACK B+ BUS (NEAR GROUND) B+ BUS (NEAR GROUND) SHORTING BAR C33 E13 R42 SOLENOIDS 1 uF 1.5KV 100 DISCONNECT 1kV 10W K40 K39 (5) (3) 31 mA AT 100kV BEAM VOLTAGE 3 CAPACITOR FAULT DISCONNECT DETECTOR (AT RIGHT- FROM DWG 2 M17 HAND END OF CAP BANK) R40 C32 J349C106 50mA FS E11 A 100 1uF 1.5KV 2W 200V EARTH GROUND 430 TRANSMITTER CAPACITOR FAULT STATUSTO K59 DWG 430_106 p2 DWG. 430_AGE THIS LINE IS GROUNDED IF CURRENT THROUGH METER M9 IS TOO LOW AC COMMON TITLE: CAPACITOR BANK KLYSTRON AGING SET-UP AND BEAM VOLTAGE CIRCUITRY DRAWN 12-98 TO REPLACE D349C105 TURN OFF MODULATOR VIA BREAKER NEAR file:430_105.ecw jbh 12-17-98 rev 8-7-02 DOOR OF KLYSTRON VAULT KLYSTRON AGING SET-UPfile:430_age.ecw jbh 2-24-03.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    1 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us