SOLAR AIR HEATERS Solar ThermalSolar ThermalSystem HeatingProcessSolarSolar SolarProcess Fruitfor ThermalHeat Commercial Thermal and Usefor Crop for Hotwith - Greenhouses How SolarWater /Silo Industrial it Dryersworks Wash SOLAR THERMAL AIR SYSTEM FOR GREENHOUSES Features TO SUPPLY HEATING, COOLING 1. Modular system assembly. Installation with minimum interference in the greenhouse growing cycle. AND CARBON DIOXIDE 2. Provides different air flows and air temperatures to parts of the greenhouse to adjust separate growing cycles. 3. Supplies carbon dioxide growth requirements from fresh air. Reduces flue gas and supplier co2 requirements. 4. Recirculates solar heated air for destratification and co2 from fresh outside air. Destratification lowers high heat losses through the roof. 5. System used for summer bypass cooling. Used to dump greenhouse hot water storage tank heat build-up. 6. Recirculation for humidity control to prevent high humidity pockets. 7. Can lower greenhouse energy costs 40-60%. Solar Infra Systems Int Ltd 209 19138 26th Avenue Surrey BC, Canada V3S 3V5 t 604 535 2056 f604 535 0681 SOLAR INFRA SYSTEMS GREENHOUSE SOLAR THERMAL UNIT MODULE Solar Thermal System for Greenhouse air heating North End and Carbon Dioxide Supply Solar Thermal Air heating bank module (See Sh2 pg2) is mounted on the south end of each Greenhouse bay. Each bay has a transparent distribution duct located in the roof apex that runs the length of the bay. The cooler solar air flow reduces the stratified temperature at the roof and lowers the roof heat loss. (See page 6) In this layout, there are 64 bays with 128 solar air/water collectors, with separate bay computer monitor and control on fan speed for air flow and water temperature for heating the air on low solar radiation periods (hot water from the greenhouse storage tank is pumped through the solar collector tubing). West In operation,in each greenhouse bay, the solar module distribution fan East (Sh2 pg2) draws air through the solar thermal bank and supplies solar heated air at the Greenhouse operating temperature (20°C). ( See Diagrams 1 to 2 pg 7-8). Green house air can also be recirculated through the solar bank to mix with fresh air and conserve the carbon dioxide content. Air flow is designed to change the air in each module 1/hr and supply 390 ppm CO2 per hour to supplement flue-gas and liquid CO2 production. Operating CO2 level is 1500 ppm. The solar bank is also set up to pump cooler night or day air to lower temperatures in the greenhouse by bypassing the collector bank. (See Diagram 3 pg9). The tubing in the solar collectors can also be used to dump heat from the greenhouse storage tank that builds up during the summer flue gas manufacture of CO2 with the greenhouse boilers. The storage tank hot water is pumped through the solar collector tubing and cooled by pumping night air through the solar collectors and exhausting to atmosphere. (See South End Diagram 4 pg10). The solar system can also be used as an air recirculation system to control high humidty-disease build ups. (See Diagram 5 pg 11) PAGE 1 4/11/2014 SOLAR INFRA SYSTEMS GREENHOUSE SOLAR THERMAL UNIT MODULE South North End End Volume 5860m3 The solar module is moved away from the south end of the greenhouse to reduce solar shading (See pg 3). The collectors can be inclined lower to move closer to the south wall if required. PAGE 2 4/11/2014 SOLAR INFRA SYSTEMS GREENHOUSE SOLAR THERMAL UNIT MODULE SOLAR SHADOW ON SOUTH END OF GREENHOUSE Reduced to 10% during main production season. Main Operating Season South If required, the End collector bank can be lowered more to move the system closer to North the south wall. End SOLAR SUN PATH FOR SITE PAGE 3 4/11/2014 SOLAR INFRA SYSTEMS GREENHOUSE SOLAR THERMAL UNIT MODULE Circulation fan Solar Module Description Fantech 18XL 5500 cfm max .75” Each solar module consists of two solar thermal air/water H20 2208 watts 3P heaters connected in parallel to an inlet duct and outlet duct. Top Duct with summer bypass In operation, the bottom inlet duct damper is opened to outside fresh air and the circulation fan on the outlet duct pulls the fresh air through the collectors and distributes the solar heated air through a transparent distribution duct 18” transparent duct running along the roof of the greenhouse bay. with holes at 45 Two SIS 616 Solar degrees to roof Air/Water Heaters There is piping in the bottom inlet duct that connects each spaced at 1m Water connected solar collector water flow tubing to the greenhouse storage Full length of bay in parallel hotwater tank. This hot water supply and return piping 228 m connects all solar units to the storage tank system in a parallel circuit. Each collector has 300 ft of corrugated stainless steel Bottom Inlet Duct tubing. with automatic damper To prevent water freezing in the collectors, when the sully pump is shut off, the water in the solar collector will Return duct with drain back into a sump tank. A nitrogen blow down is also Greenhouse Bay damper control provided to make sure the solar tubing is cleared. 4m x 230m x 5m h Fan speed, inlet dampers and air flow ducts are computer controlled and monitored to adjust air flow. Top Duct with auto Water flow and isolation valving for each solar collector summer bypass, is located in the bottom inlet damper. nitrogen purge, insect screen All inlet and outlet ducts have filters and screens to control dust and insects. Two SIS 616 Solar Air/Water Heaters Area 35m2/unit Bottom Inlet Duct with automatic damper, water piping, insect screen PAGE 4 4/11/2014 SOLAR INFRA SYSTEMS GREENHOUSE SOLAR THERMAL UNIT MODULE Solar Module Description Distribution duct 18” At the north end of the distribution duct the end can be transparent with holes sealed or connected to an inlet fan for night cooling (See every meter Diagram 3-4 pg 9-10). The exhaust ducts and return ducts are opened to atmosphere to direct greenhouse air out of the module. North End Exhaust Duct with Manual Damper transparent Circulation Fan duct Top Duct with summer bypass nitrogen purge SIS 616 Solar Heater Bank (2) tilted 50 degrees Greenhouse Bay Inlet Duct with controlled damper Water piping and connections Greenhouse Mounting stand return duct not shown with auto damper PAGE 5 4/11/2014 SOLAR INFRA SYSTEMS GREENHOUSE SOLAR THERMAL UNIT MODULE Roof Heat Loss (through glass) solar .destratification lowers heat loss Solar heated by reducing the roof temperature I fresh air from Indoor Temperature - Building Stratification the solar bank In a Industrial solar application, you enter the temperature Duct stratification in the building before installation of the solar air 20°C heater. This value represents the difference between the air TEMP 26°C temperature measured at ceiling level and the air temperature measured near the floor. SOLAR INLET AIR In high-ceiling industrial buildings, there can be a significant temperature gradient between the floor and the ceiling as heat Solar Inlet air is cooler and heavier generated within the building naturally rises. This effect, known as than the ceiling statified air. Mixed stratification, can result in increased heat loss through the roof with ceiling air brings the blended air and through rooftop exhaust vents. down to the working level A solar destratification ventilation system can reduce this effect by delivering relatively cool ventilation air at ceiling level, Solar destratification pressurizes promoting mixing of indoor air. In doing so, the ceiling air the building and eliminates drafts. temperature is reduced and the building temperature becomes more uniform, thus less stratified. Stratification temperature can be measured directly in an existing building. Buildings with low ceilings, and low internal gains (e.g. warehouses) will have modest stratification (1 to 6 ºC). Generally 1°C per meter in height is used. For a 16ft plus apex (6.37m) greenhouse, the stratification temperature difference used is 6°C. Buildings with high ceilings and high internal gains (e.g. manufacturing facilities) may have significant stratification (5 to 15 ºC). The system pressurizes the greenhouse and reduces entry of gnats and other harmful insects. Hot air rises and stratifies in layers at approximately 1°C per meter in height TEMP 20°C PAGE 6 4/11/2014 SOLAR INFRA SYSTEMS GREENHOUSE SOLAR THERMAL UNIT MODULE Diagram 1: Standard Operation: Solar Heated Air Supply for Destratification and Carbon Dioxide from Fresh Outside Air 1. Solar Air CO2 content: 390 ppm (0.35 kg/100m2)( .756g/m3) Greenhouse Operating CO2 level:1500 ppm 2. Air Flow per Greenhouse Module (230m x 4m x ((4.87*4) +6)= 5860 m3/hr 1 air change/hr 3. CO2 delivery/hr = 5890m3*.756 g/m3=4.45kg/module/hr Solar CO2 =390/1500= 26% of requirements 4. Operating Temperature: 20°C Stratification= 1°C/m height. Roof Heat Loss Exhaust Fan 2 Fan 1 Stratification Temp 26°C Destratification Distribution Duct Bypass Damper Switch Inlet Box Damper and Filter SOLAR AIR FLOW (CO2 390 ppm) RADIATION North South End Solar End Collector Operating Temp 20°C Bank (2) Water tubing 300ft/collector Inlet Exhaust Damper Damper Exhaust and Filter Carbon Dioxide Gas Distribution System Recirculation Duct CO2 Concentration 1500ppm GREENHOUSE MODULE Vol= 5860m3 (230ml x 4mw x 6.37mh) Switch Box Hot Water OPERATION from Water 1. Timer or sensor activates (Fan 1) and draws fresh outside air into the bottom damper and through the solar collectors. Storage Tank return to 2. The solar collectors heat the air (20°C) and pump it into the distribution duct tube along the roof of the greenhouse module.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages13 Page
-
File Size-