Intention Tremor- a Method of Measurement

Intention Tremor- a Method of Measurement

J Neurol Neurosurg Psychiatry: first published as 10.1136/jnnp.38.3.253 on 1 March 1975. Downloaded from Journal ofNeurology, Neurosurgery, and Psychiatry, 1975, 38, 253-258 Intention tremor- a method of measurement M. H. MORGAN, R. L. HEWER, AND R. COOPER From the Department ofNeurology, Frenchay Hospital, Bristol SYNOPSI S A method of measuring and analysing intention tremor using a linear accelerometer is described. Reasons are given for measuring this particular parameter of the tremor, for using this specific energy conversion device, and for employing the particular form of analysis. A comparison of the numerical values obtained for the amount of tremor activity, compared with a corresponding clinical grading, is made for 30 patients with intention tremor due to a variety of pathological causes. It is shown that the method gives clear correlation with the clinical assessments, although certain discrepancies are noted, and their importance discussed. Tremor may be defined as a series ofinvoluntary, of the cerebellum (Holmes, 1939). Analysis of relatively rhythmic, purposeless, oscillatory motion pictures has been used in an attempt to movements involving a part or parts of the body obtain a better representation of time and space Protected by copyright. moved by skeletal muscle (Brumlik and Yap, (Dierssen et al., 1961). These methods were 1970). When tremor occurs during voluntary laborious to analyse and were not easily repeated movement it may be called 'intentional', to dis- for statistical appraisal. Indirect methods of tinguish this form of abnormal movement from measuring intention tremor have also been either tremor of a limb at rest, often called static developed. Chase and his colleagues in 1965, tremor, or tremor of a limb extended against used a linear rotary motion potentiometer to gravity, often called anti-gravity tremor. It has generate a signal proportional to the movement been stated that a study of involuntary move- of the subject's finger in a vertical plane. The ments presents a difficult but challenging task subject was then required to maintain his finger (Liversedge, 1962) but reports of attempts to at a reference point in space while visual displays treat intention tremor have recently shown a were presented on a cathode ray tube to give small measure of success (Cooper, 1965; Hewer information about finger position and reference et al., 1972). Objective evaluation of progress position. This compensatory tracking task pro- and treatment of involuntary movements has vided quantitative data about control of volun- proved a particularly difficult problem. Thus, tary movement. Such data provide only indirect http://jnnp.bmj.com/ many methods exist to measure tremor in the information, for the limb is not free to move in resting limb, but very few of these have been space, and the task cannot readily be compared applied to intention tremor. The problem of with the clinical examination, nor with the sub- measurement and analysis of intention tremor is ject's usual performance of everyday tasks. complicated because of the three-dimensional More recent technological advances have pro- aspects of movement of a limb in space, because vided transducers which may be used to produce of the rapidity of the positional changes, and an immediate graphical representation oftremor. because of related movements of other parts of However, most published reports refer to the on October 1, 2021 by guest. the body. In addition, there are marked varia- rhythmic tremor at rest, or on action against tions in the severity of the disability with repeti- gravity, of patients with Parkinson's disease, or tion of the task. of normal subjects (Brumlik, 1962; Yap and Tracings of simple movements on a revolving Boshes, 1967). The present study is an attempt drum have been used to provide a graphic to investigate the use of a linear accelerometer to representation of intention tremor due to lesions graph intention tremor, and to evaluate a method (Accepted 13 September 1974.) of analysing these traces to produce quantifiable 253 J Neurol Neurosurg Psychiatry: first published as 10.1136/jnnp.38.3.253 on 1 March 1975. Downloaded from 254 M. H. Morgan, R. L. Hewer, and R. Cooper data. A preliminary study with a small group of ment of a simple motor task performed by the patients has already been reported (Morgan et al., patient. 1972), and this work has since been extended to The task was a simple one, consisting of hori- include a larger group of patients with intention zontal movement of the pronated limb, from the shoulder to a target button placed at a suitably tremor of varying severity. Assessment of dis- adjusted arm range directly in front of the patient's ability enables various methods of treatment to shoulder. The patient was instructed to move his be compared objectively, and the development arm slowly and steadily towards the target button, of this particular method forms part of a project taking approximately four seconds for the perform- investigating possible means of reducing dis- ance of the task. Practice with a stop clock was ability due to intention tremor. undertaken until this could be achieved on most attempts. During recording, only the attempts which METHODS took approximately four seconds were retained for PATIENTS Clinical assessments and recordings were analysis. In order to minimize the effect of fatigue, a made on a series of 30 patients who exhibited tremor two minute rest period was allowed between each during the performance of voluntary movements. trial procedure. The output from the accelerometer The clinical diagnoses for these 30 patients were as was recorded, using an Elema-Schonander Mingo- follows, with the numbers of patients given in graph. A standard amplifier gain, such that an out- parentheses: put of 1 g gave 1.5 cm deflection of the recorder, Multiple sclerosis (10), cerebellar degeneration of was used throughout the experiments. unknown cause (five), idiopathic or essential tremor The apparatus was connected on line to a Linc 8 (five), Friedreich's ataxia (two), cerebrovascular computer and the data were sampled at a rate of 128 points per second. A known calibration signal of 1 g disease affecting the brain-stem territory (two), Protected by copyright. congenital lesions affecting the basal ganglia (two), was sampled before each series of recordings, and traumatic lesions affecting the brain-stem territory the signal displayed on the computer oscilloscope and cerebellum (two), tumour of the cerebellum was normalized to produce a standard deflection. (one), and Parkinson's disease (one). The ages of the This procedure ensured that all experimental data patients in the series ranged from 14 to 65 years, were comparable for each patient. with a mean age of41 years; there were 17 males and Pressure on the target button caused sampling to 13 females. Eleven patients had mild tremor, nine stop and the accelerometer output obtained during moderate, six severe, and four very severe tremor of the immediately preceding four seconds was dis- their dominant hand, as judged by clinical assess- played on the computer oscilloscope screen. The test ments and simple rating tests. TREMOR MEASUREMENTS Clinicalassessments Tasks of manual dexterity, such as the finger/nose and pronation/supination tests, as well as a series of maze and pattern drawing tests were employed. A four point rating scale of tremor severity was based on a visual estimate of severity of the tremor, where a http://jnnp.bmj.com/ score of 1 indicated mild tremor, 2 moderate, 3 severe, and 4 very severe tremor. Grades 3 and 4 indicated tremor severe enough to cause inter- ference with the patient's daily tasks such as dressing, eating, and drinking. No patient exhibited marked v V weakness of the dominant limb, and only one patient had loss of position sense in the fingers. Recording procedure Tremor was recorded with a on October 1, 2021 by guest. linear accelerometer (M.E.M. Electro Mechanisms Ltd, Slough), weighing 25 g, size 3.0 x 2.1 x 1.1 cm, with an acceleration range of plus or minus 6 g. The transducer was strapped tightly to the dorsum of the FIG. 1 Three accelerometer recordings from a hand at the base of the index finger. Its active axis patient with multiple sclerosis. The duration of each was sensitive to movements in a horizontal plane, trace is 2 s and the calibration signalfor the accelero- which was at right angles to the direction of move- meter is shown. J Neurol Neurosurg Psychiatry: first published as 10.1136/jnnp.38.3.253 on 1 March 1975. Downloaded from Intention tremor-a method of measurement 255 data could then be stored on computer tape for later cedure made use of a Fourier analysis of the wave- analysis. form. The component frequencies from 0 to 64 Hz, in i Hz steps, were displayed on a computer screen as Analysis oftremor traces The stored data contained a frequency power spectrum. Each spectrum dis- steady level and low frequency components, due to played could be subjected to certain modifications the acceleration and deceleration of the limb to- by means of the control programme. Frequencies wards the target, and accentuated by any minor between 0 and 2 Hz were erased from the traces, and rotation of the accelerometer due to rotation of the the reconstituted wave form was then compared limb. These frequencies, below 2 Hz, were considered with the original trace. Any magnification factor due to be unwanted artefact. To remove these, the stored to the analysis could be corrected, and the trace was data were subjected to a frequency analysis. The pro- then balanced about a mean, rectified and inte- gramme which was written to perform this pro- grated. From this procedure it was therefore pos- sible to obtain a numerical value which represented the amount of tremor activity in arbitrary units for each four seconds test run.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    6 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us