101M ProLinx Gateway IEC 60870-5-101 Master March 14, 2012 PROTOCOL MANUAL Your Feedback Please We always want you to feel that you made the right decision to use our products. If you have suggestions, comments, compliments or complaints about our products, documentation, or support, please write or call us. How to Contact Us ProSoft Technology 5201 Truxtun Ave., 3rd Floor Bakersfield, CA 93309 +1 (661) 716-5100 +1 (661) 716-5101 (Fax) www.prosoft-technology.com [email protected] Copyright © 2012 ProSoft Technology, Inc., all rights reserved. 101M Protocol Manual March 14, 2012 ProSoft Technology ®, ProLinx ®, inRAx ®, ProTalk ®, and RadioLinx ® are Registered Trademarks of ProSoft Technology, Inc. All other brand or product names are or may be trademarks of, and are used to identify products and services of, their respective owners. ProSoft Technology ® Product Documentation In an effort to conserve paper, ProSoft Technology no longer includes printed manuals with our product shipments. User Manuals, Datasheets, Sample Ladder Files, and Configuration Files are provided on the enclosed CD-ROM, and are available at no charge from our web site: www.prosoft-technology.com Important Installation Instructions Power, Input, and Output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods, Article 501-4 (b) of the National Electrical Code, NFPA 70 for installation in the U.S., or as specified in Section 18-1J2 of the Canadian Electrical Code for installations in Canada, and in accordance with the authority having jurisdiction. The following warnings must be heeded: A WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIV. 2; B WARNING - EXPLOSION HAZARD - WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE REPLACING OR WIRING MODULES C WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON-HAZARDOUS. D THIS DEVICE SHALL BE POWERED BY CLASS 2 OUTPUTS ONLY. ProLinx ® Products Warnings WARNING – EXPLOSION HAZARD – DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON-HAZARDOUS. AVERTISSEMENT – RISQUE D'EXPLOSION – AVANT DE DÉCONNECTER L'EQUIPMENT, COUPER LE COURANT OU S'ASSURER QUE L'EMPLACEMENT EST DÉSIGNÉ NON DANGEREUX. ProLinx Gateways with Ethernet Ports Series C ProLinx™ Gateways with Ethernet ports do NOT include the HTML Web Server. The HTML Web Server must be ordered as an option. This option requires a factory-installed hardware addition. The HTML Web Server now supports: 8 MB file storage for HTML files and associated graphics files (previously limited to 384K) 32K maximum HTML page size (previously limited to 16K) To upgrade a previously purchased Series C model: Contact your ProSoft Technology distributor to order the upgrade and obtain a Returned Merchandise Authorization (RMA) to return the unit to ProSoft Technology. Markings Electrical Specifications Label Markings CL I Div 2 GPs A, B, C, D II 3 G Ex nA nL IIC X -20°C <= Ta <= 60°C II – Equipment intended for above ground use (not for use in mines). 3 – Category 3 equipment, investigated for normal operation only. G – Equipment protected against explosive gasses. Agency Approvals and Certifications cULus Class I, Div 2 Groups A, B, C, D T6 -30°C <= Ta <= 60°C 183151 101M ♦ ProLinx Gateway Contents IEC 60870-5-101 Master Protocol Manual Contents Your Feedback Please ........................................................................................................................ 2 How to Contact Us .............................................................................................................................. 2 ® ProSoft Technology Product Documentation .................................................................................... 2 Important Installation Instructions ....................................................................................................... 3 ® ProLinx Products Warnings ............................................................................................................... 3 ProLinx Gateways with Ethernet Ports ............................................................................................... 3 To upgrade a previously purchased Series C model: .................................................................... 3 Markings .............................................................................................................................................. 4 1 Introduction 9 1.1 Quick Start ............................................................................................................... 10 1.2 Functional Overview ................................................................................................ 19 1.2.1 IEC 60870-5-101 Master Protocol Implementation ................................................. 19 1.2.2 101M Data Types .................................................................................................... 21 2 Port Physical and Protocol Specifications 23 2.1 General Specifications ............................................................................................ 24 2.2 Master Functional Specifications ............................................................................ 25 2.2.1 Driver Protocol Specifications ................................................................................. 25 3 Configuring the Gateway 27 3.1 Installing ProSoft Configuration Builder Software ................................................... 27 3.1.1 Using the Online Help ............................................................................................. 28 3.2 Adding a Module ..................................................................................................... 29 3.3 Configuring Module Parameters ............................................................................. 30 3.4 Creating Optional Comment Entries ....................................................................... 31 3.5 Printing a Configuration File .................................................................................... 32 3.6 101M Protocol Configuration ................................................................................... 33 3.6.1 [IEC-101 Master Commands] .................................................................................. 33 3.6.2 [IEC-870-5-101 Master] ........................................................................................... 36 3.6.3 [IEC-870-5-101 Master Port x] ................................................................................ 36 3.6.4 [IEC-101 Master Session x]..................................................................................... 38 3.6.5 [IEC-101 Master Session x Sector y] ...................................................................... 40 3.6.6 Using the CommonNet Data Map ........................................................................... 43 3.7 Downloading a File from PC to the Module ............................................................. 47 4 LED Indicators 49 4.1 LEDs for Port 0 Serial Port ...................................................................................... 50 5 Debug Information 51 5.1 Main Menu ............................................................................................................... 52 5.1.1 Redisplaying the Menu ............................................................................................ 52 5.1.2 Viewing Module Configuration ................................................................................ 52 ProSoft Technology, Inc. Page 5 of 113 April 28, 2011 Contents 101M ♦ ProLinx Gateway Protocol Manual IEC 60870-5-101 Master 5.1.3 Opening the Database View Menu ......................................................................... 52 5.1.4 Opening the Session Configuration Menu .............................................................. 52 5.1.5 Opening the IEC-101 Master Menu ........................................................................ 53 5.1.6 Sending the Configuration File ............................................................................... 53 5.1.7 Viewing Version Information ................................................................................... 53 5.1.8 Opening the Data Map Menu .................................................................................. 53 5.1.9 Exiting the Program ................................................................................................ 53 5.2 IEC-101 Master Driver Menu .................................................................................. 54 5.2.1 Opening the Data Analyzer Menu .......................................................................... 54 5.2.2 Viewing General Configuration ............................................................................... 54 5.2.3 Opening the IEC-870-Master Command List Menu ............................................... 55 5.2.4 Opening the Port Configuration Menu .................................................................... 55 5.2.5 Opening the Port Status Menu ............................................................................... 56 5.2.6 Opening the Session Configuration Menu .............................................................. 56 5.2.7 Opening the Sector Menu ....................................................................................... 56 5.2.8 Viewing Master Driver Version Information
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages113 Page
-
File Size-