Silo Protect Fire Protection Solution for Silos and Bunkers Valuautomatic

Silo Protect Fire Protection Solution for Silos and Bunkers Valuautomatic

BRANCH SOLUTION Silo Protect Fire protection solution for silos and bunkers VALUautomatic Risk When wood-based panels are manufactured, highly combustible material is generated during the production process and is transported to enclo- sed silos or bunkers. Mechanical discharching, conveying or preparation devices are all potential ignition sources. In the vi- cinity of the discharge screw conveyers in silos or at the bearing of the needle rollers in bunkers friction and overheating of material can cause a deep seated unrecognisable smouldering fire. Ignition sources carried in through the feed ope- ning also present a potential fire risk. This is safely controlled with our spark detection and extinguishing system. Another possible cause of fire is self ignition ari- sing from the biological decompo sition process. When a concealed, smouldering fire spreads to a surface area and is exposed to oxygen, it can quickly develop into an open fire that can destroy the entire machine. Under certain conditions, it can even lead to an explosion. The high concentration of fine particles and car- bon monoxide, and the often existing high relative humidity make it difficult to detect incipient fires inside silos or bunkers. This volatile combination of high fine particle con- cen tration and relative humidity has made early fire detection extremely difficult up until now. In the past, only temperature detectors could be used under these extreme environmental con diti- ons. These could only detect a fire with an open flame, which caused considerable delay in the extinguishing procedure, thus enormously impeding extinguishing activities. BRANCH SOLUTION ABLEfirefighting Solution In order to early detect this fire risk, a system has been developed in various pilot plants that Spark detection meets these special requirements. The HELIOS Spark extinguishing AMX5000 aspirating smoke detector, already in use in other areas, has been successfully applied here by Minimax using a combination of filters Suction tube Filter and dust separators. The HELIOS AMX5000 aspirating smoke de- tector continuously takes air samples from the silo or bunker area. These air samples are tested for carbon monoxide and smoke par- ticle content. When several freely adjustable concentration values are exceeded, an alarm is activated and a fire extinguishing system may optionally be triggered. A specially developed filter removes the large particles from the air-dust mix that is sucked into the bunker. The fine particles and water are then removed in another procedure. Separator Extin- HELIOS guishing AMX5000 system 1 2 3 4 5 6 7 8 9 int. 0 ext. Menu Reset FMZ 5000 Brandmeldesystem Fire Detection System Made in Germany ADVANTAGESby fire detection Phased alarm activation High functional reliability through the use of CO alarm + smoke alarm = fire alarm multisensors for smoke aerosols and carbon Typical signal pattern during a smouldering fire monoxide Carbon monoxide build-up GMX5002 CO The tried-and-tested system for particle pre- Signal level Smoke build-up AMX5000 Conflagration cipitation, air flow monitoring and function- gas detector monitored sensors ensure the highest possible reliability Alarm threshold Smoke alarm Aligned with typical disturbance signals CO alarm Smoke detector through intelligent analysis algorithms Time Freely adjustable alarm thresholds available for signal processing Integrated self-learning mode in AMX5000 for adaptation to environmental conditions Extinguishing Robust industrial design The FMZ 5000 fire alarm control panel automat - ic ally activates the Minimax fire supression Application in ex-dust zone 20 possible system. Regardless of the fire load in question, as a company offering a full range of services, A blow-through system for filter cleaning we have both water and gas extinguishing sys- can be integrated into the system tem in our portfolio and adapt each individual system to your requirements. For a completely Automatic Minimax firefighting equipment safe fire protection. can be actuated Printed in Germany FMZ 5000 4365 Federal Drive Greensboro, NC 27410 Phone (336) 299-2933 Fax (336) 299-2944 AL18e/04.09/2/05.09 HELIOS AMX5000 www.flamexinc.com We reserve the right to make technical changes..

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    4 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us