
USER MANUAL PAGE LEFT INTENTIONALLY BLANK FOR PAGINATION PURPOSES Pagina 2 di 56 REV. 03/2005 INDEX System requirements .............................................................. 4 1. Software and driver Installation.............................................. 4 2. First Start-Up ................................................................ 5 3. Security...................................................................... 6 4. The Menu...................................................................... 8 4.1 The Toolbar. ............................................................. 12 5. Creating a New Project ....................................................... 13 5.1 The Sprite ............................................................... 14 5.1.1 Gradient Panel ..................................................... 16 5.1.2 Text Panel ......................................................... 17 5.1.3 Picture Panel ...................................................... 18 5.1.4 Borders Panel ...................................................... 19 5.1.5 Settings Panel ..................................................... 20 6. Barcode ..................................................................... 21 7. Magnetic Encoder ............................................................ 22 8. Connecting a Database ...................................................... 23 8.1 Editing the Database Records ............................................. 27 9. Data Linking Using Microsoft Provider for Database .......................... 28 9.1 Example Oledb for Sql Server ............................................. 29 9.2 Example Oledb for Oracle ................................................. 31 9.3 Example OleDb for ODBC driver ............................................ 33 9.4 Example OleDb for Jet 4.0 for Dbase files ................................ 35 10. Rowset Manager ............................................................. 38 11. Creating an Internal Database .............................................. 39 12. Field Engine ............................................................... 41 13. To Print ................................................................... 43 14. Saving the Project ......................................................... 45 15. Video Capture – OCR server ................................................. 46 15.1. Display Menu ............................................................ 52 15.2. Configuration Menu...................................................... 53 REV. 03/2005 Pagina 3 di 56 System requirements Before installing Rainbow, you must have at least these minimal computer requests: 1. Pentium III class or more higher, 128Mb RAM 2. Operating System Windows98, Me, Nt (sp6), 2000 (Sp3), Xp (sp1) 3. Explorer 5.0 or higher properly installed 4. MS Access97 or higher properly installed (for advanced database managing) 5. The video card resolution set to 24-bit depth (16.8 millions of colours) and at least the video matrix set at 800x600 or more. 1. Software and Driver Installation INSTALLATION NOTES: Please remember that this software cannot run if a previous version has been installed on the computer. Before installing this new software release, please remove the old version (Start/Settings/Control Panel/Add-Remove Programs) and remove the old working folder (do this manually). Also ensure that the file "Pegaso.ocx" contained in the Window/System (Winnt/System32) directory has been removed. If necessary, remove it manually. *** ATTENTION *** Remember that you cannot use your job files created with Rainbow release 1.4 or older with this new software version. To install the “Rainbow” software: • If the CD automatically launches the file index.htm, select a language and follow the instructions. Otherwise, in the Windows “START” menu, select Run and type “X:\index.htm”, where X represents the letter used for your CD drive. • Select the printer model you want to install • Select the Rainbow Software icon displayed on the screen • A new window is displayed: select ‘Run this program from its current location’ • Then select ‘OK’ • A new window is displayed to indicate that an authentic signature has not been found. Select Yes • The installation screen for the components required by Rainbow is now displayed. • Check again if the resolution of your screen is at least 800x600 with 24 bit colour depth (True colour). • If so, select the first MFC icon and follow the indications on the screen. You are advised to leave the default settings. • Carry out the same operations to install the OLE DB components. ATTENTION! During installation, a screen will be displayed which has an icon for a computer with a small globe and the Exit Setup icon at the bottom. If you are using an update version of Windows, you may receive an ‘FATAL ERROR SETUP’, but this means only that you have the same or a new release of these software libraries. Please continue to install the third application. Pagina 4 di 56 REV. 03/2005 • Once you have installed these program libraries, select the Rainbow icon and continue with the installation. Leave the TYPICAL installation option and do not alter the installation path, leaving the default settings unchanged. • At the end, the program asks you to restart your PC (this may also be required on some computers at the end of the installation of the previous two programs. • When you have restarted your computer, the desktop contains the Rainbow icon and the Start-Programs file includes a Rainbow file. VERSION INFO Please remember that odd minor version numbers (like 1.1, 2.3, 4.7 and so on) are development releases. On the other hand, even minor version numbers identify stable releases. Stable releases appear in one version only. Example: there is only one 2.0 version. The Cim technical support service assists with stable versions only. 2. First Start-up At first start-up, no password will be required, and the main Rainbow window will be opened. For subsequent access, to modify or cancel the password, refer to the “SECURITY” section. REV. 03/2005 Pagina 5 di 56 3. Security In the “View” menu, select the “Security” command. This allows you to manage and handle all the users by assigning the various privileges. When you select this many, the software will show the password request: it will be required to enter an “Admin” user password. The default password is also “Admin” with the “A” in capital case, then press “OK” button. If you have set a different password, please insert it with capital and minor case characters in properly places. Pagina 6 di 56 REV. 03/2005 • Password Encrypted: If enabled, it leaves asterisk digits instead of your password characters • Program Protection: If enable, every time you start Rainbow software the password is requested • Privilege: o Change Layout Job By means this privilege the user can modify the card layout, adding or modifying the graphic objects. o Data Source Allow user to access at the “Edit Database” dialog window Hardware Info Setup o Job Setup Allow user to modify the settings of the window “Job Setup” • Change: Apply the changes at the current user selected • Delete user: Remove the current user selected (except if the user has administrator privilege) • Set User: Set the account selected as current software user • Set Admin: Give to the current accout the administrator privilege • New User: Create a new account with the current options selected • Exit: Exit from this Security Panel (press Change to save the modification before exit) Note: After every changes press “Change” button to save these modifications REV. 03/2005 Pagina 7 di 56 4. The Menu File New : creates and opens a new Project Layout It will be require to type the project name (a new folder with the project name will be created). Open : opens an existing Layout. Close: Close the current project. Save : saves the Job with its current name. Save As: saves the Job with a new name. Print: prints the Job using the settings specified in the Job/Setup menu. Print preview: displays a print preview for the Job. Print Setup: Select the printer to be used and change the driver settings. Exit: Quit the program. Edit Cut: copies the object selected in the clipboard and removes it from its current position. Copy: copies the object selected in the clipboard. Paste: takes the object previously copied in the clipboard and pastes it in the current layout. Delete: eliminates the object selected (this can also be done using the CANC key). Pagina 8 di 56 REV. 03/2005 View Toolbar: If ticked in the check box, the toolbar is displayed. Status Bar: If ticked in the check box, the status bar is displayed. Magnetic Tracks: opens the Show Tracks dialog box allow display the tracks on the card layout. Attention, this options doesn’t change the magnetic settings, it is only a graphical indication. Microchip: Show the microchip on the card layout where usually is inserted into the plastic card Grid Setting: Opens the Grid Settings dialog box allow to display the card layout with the grid: Options(Hide/Show) :Show or Hide the grid on the card Spacing(Width/Height):Set the distance between the points of the grid Snap control to grid :Align the sprites to the grid (if Grid is enabled) Portrait/Landscape Mode: Allow to set the landscape or portrait visual mode of the card Anchor Sprites to card layout: If enabled, anchor the sprites to the card current position when you turn the card orientation with the Orientation options (Portrait/Landscape mode). REV. 03/2005 Pagina 9 di 56
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages54 Page
-
File Size-