Why Enthalpy Economizers Don't Work

Why Enthalpy Economizers Don't Work

This article was published in ASHRAE Journal, November 2010. Copyright 2010 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. Reprinted here by permission from ASHRAE at www.taylor-engineering.com. This article may not be copied nor distributed in either paper or digital form by other parties without ASHRAE’s permission. For more information about ASHRAE, visit www.ashrae.org. Economizer High Limit Controls and Why Enthalpy Economizers Don’t Work By Steven T. Taylor, P.E., Fellow ASHRAE; and C. Hwakong Cheng, Member ASHRAE utdoor air economizers use controllable dampers to increase the amount of chart showing entering coil conditions that have a higher dew-point tempera- Ooutside air drawn into the building when the outside air is cool or cold and ture than the desired supply air tempera- ture so the air is dehumidified (wet coil). the system requires cooling. They are required by energy standards such as Standard Coil cooling energy is proportional to the enthalpy difference across the coil 90.11 in most commercial cooling applications. A typical design is shown in Figure 1. from the entering condition to the sup- ply air condition. The return air condi- Supply air temperature is maintained at setpoint by first opening the economizer tion in this example is 76°F (24°C) dry- bulb temperature with a humidity ratio outdoor air damper and closing the return air damper, then opening the chilled water of 68 grains/lbda (0.01 gw/gda) (1 grain = 7,000 lb ). If the outdoor air were valve if additional cooling is required. A key element of the economizer control system w 78°F and 60 grains/lbda (26°C and 0.09 g /g ) (outdoor air condition #2, green is the high limit switch that determines whether outdoor air is, in fact, appropriate for w da dot, Figure 2), the enthalpy difference cooling and enables or disables the economizer dampers accordingly. This high limit across the coil would be less than that required to cool return air to the supply device, which has long been misunderstood, is the subject of this article. air temperature despite the fact that the The purpose of the high limit switch energy than cooling outdoor air. Deter- About the Authors is to disable the economizer when its mining when the changeover condition Steven T. Taylor, P.E., C. Hwa- use would increase the energy used by occurs is complicated by the fact that is a principal and kong Cheng is a designer at Taylor Engineering the cooling coil, i.e., when cooling re- cooling coils both cool and dehumidify LLC, a consulting engineering firm in Alameda, turn air will use less mechanical cooling supply air. Figure 2 is a psychrometric Calif. November 2010 A SHRAE Journal 1 dry-bulb temperature is higher than the Economizer Minimum OA OA Damper return air dry-bulb temperature. This Supply Fan is because the outdoor air results in a Damper lower latent cooling load. Conversely, if Outdoor Air the outdoor air were 74°F and 92 grains/ Supply Air Temperature Sensor lbda (23°C and 0.13 gw/gda) (outdoor air condition #1, red dot, Figure 2), it would RA CHW Valve take more energy to cool than the return High Limit Damper Switch air despite having a lower dry-bulb tem- Return Supply Air perature, due to the higher latent load Air Temperature Controller component. So, with a wet coil (if the return air has a higher dew-point tem- Figure 1: Outdoor air economizer controls. perature than the supply air temperature setpoint, assuming near saturated conditions leaving the coil as is typical of a wet coil), the optimum economizer high limit logic is to cool the airstream that has the lower enthalpy. The physics of a dry coil is quite different. In Figure 3, entering coil dew-point temperatures are below the supply air temperature dew point, so no dehumidification occurs. The energy use across the coil is still proportional to the enthalpy difference, but the leaving air is no longer near saturation; the humidity ratio is the same as the entering airstream. With a dry coil, cooling outdoor air from 81°F and 46 grains/lbda (27°C and 0.07 gw/gda) takes more energy than cooling the return air, despite a lower enthalpy. Therefore, optimum dry coil logic is to cool the airstream that has the lowest dry-bulb temperature, regardless of humidity. Humidity Ratio, grains/lb of Dry Air These two figures are combined in Figure 4. Interestingly, only seldom is this combined wet/dry (enthalpy/dry-bulb) 2 logic recognized as being optimum. For instance, ASHRAE’s Dry-Bulb Temperature (°F) new green building Standard 189.13 has requirements for en- thalpy and dry-bulb high limit devices, but no requirement for Figure 2: Optimum high limit logic: wet coil. combined enthalpy and dry-bulb high limit logic. In these figures and in the discussion later, it is assumed that the economizer is fully “integrated,” meaning the economizer and mechanical cooling can operate simultaneously. This is al- ways true of chilled water systems and those direct expansion (DX) systems with modulating or several stages of capacity control, but it is generally not the case for small DX units with limited unloading capability. The optimum economizer con- trol for non-integrated or partially integrated DX equipment will vary by application and, in humid climates, must consider the impact on space humidity that results from compressor cy- cling. The results and recommendations discussed below may not apply to these non-integrated economizers. For fully inte- grated economizers, the selection of high limit control will not Humidity Ratio, grains/lb of Dry Air cause any increase in humidity in humid weather. This can be seen in Figure 2; the supply air condition is the same regard- Dry-Bulb Temperature (°F) less of entering air condition, and it is the supply air condition that determines the room humidity. Figure 3: Optimum high limit logic: dry coil. High Limit Control Strategies • Differential (or dual) enthalpy; and The most common high limit controls are: • Combinations of the above. • Fixed dry-bulb temperature; Each of these controls has inherent errors—conditions • Differential (or dual) dry-bulb temperature; where they make the wrong choice between the outdoor air • Fixed enthalpy; and return airstreams—causing an increase in energy use 2 A SHRAE Journal a s h r a e . o r g N ovember 2010 Humidity Ratio, grains/lb of Dry Air Humidity Ratio, grains/lb of Dry Air Dry-Bulb Temperature (°F) Dry-Bulb Temperature (°F) Figure 4: Optimum high limit logic: wet or dry coil. Figure 5: Fixed dry-bulb high limit error: setpoint 72°F. Humidity Ratio, grains/lb of Dry Air Humidity Ratio, grains/lb of Dry Air Dry-Bulb Temperature (°F) Dry-Bulb Temperature (°F) Figure 6: Fixed dry-bulb high limit error: setpoint 65°F. Figure 7: Differential dry-bulb high limit error. compared to the ideal logic (Figure 4). These errors increase ditions where the control strategy makes an error by incorrectly in practice due to sensor calibration error. These issues are selecting the more energy intensive airstream. In this example, discussed in more detail for each high limit control below. the return air is 76°F and 68 grains/lbda (24°C and 0.01 gw/gda); this condition varies throughout the year. In the upper red tri- Fixed Dry-Bulb Temperature angle, the control incorrectly supplies humid outdoor air. In the With a fixed dry-bulb high limit, outside air temperature lower red rectangle, the control incorrectly disables the econo- is measured and compared to a fixed setpoint, enabling the mizer when outdoor air would have reduced coil load. economizer if the outdoor air temperature is below the set- Figure 6 is the same chart with a setpoint of 65°F (18°C). point. This was the first, and remains the simplest and least This setpoint reduces the number of hours the control incor- expensive high limit control, requiring only a single tem- rectly supplies humid air (upper triangle), but it increases the perature sensor or thermostat mounted in the outdoor air- number of hours when the economizer incorrectly is disabled stream. in dry weather. In humid climates, those with many hours in Figure 5 is a psychrometric chart showing fixed dry-bulb the upper triangle and fewer hours in the lower rectangle, this control with setpoint equal to 72°F (22°C) superimposed over lower setpoint will improve efficiency. This will be seen in the ideal control. The areas shaded in red represent outside air con- energy simulations discussed below. November 2010 A SHRAE Journal 3 Weather Hours Weather Hours 117 to 105 63 to 57 104 to 92 56 to 50 91 to 79 49 to 43 78 to 66 42 to 36 65 to 53 35 to 29 52 to 40 28 to 22 39 to 27 21 to 15 26 to 14 14 to 8 13 to 1 7 to 1 Humidity Ratio, grains/lb of Dry Air Humidity Ratio, grains/lb of Dry Air Dry-Bulb Temperature (°F) Dry-Bulb Temperature (°F) Figure 8: Differential dry-bulb high limit error: San Francisco. Figure 9: Differential dry-bulb high limit error: Atlanta. Weather Hours 72 to 65 64 to 57 56 to 49 48 to 41 40 to 33 32 to 25 24 to 17 16 to 9 8 to 1 Humidity Ratio, grains/lb of Dry Air Humidity Ratio, grains/lb of Dry Air Dry-Bulb Temperature (°F) Dry-Bulb Temperature (°F) Figure 10: Fixed enthalpy high limit error.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    11 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us