NEMA Contactors and Starters

NEMA Contactors and Starters

NEMA Contactors and Starters NEMA AN16DN0AB 2.1 Freedom Series 2 NEMA Size 1 Starter Product Overview . V5-T2-2 Features, Benefits and Functions . V5-T2-2 2 Standards and Certifications . V5-T2-3 Catalogue Number Selection . V5-T2-3 2 Contactors—Non-Reversing and Reversing . V5-T2-4 2 Starters—Three-Phase Non-Reversing and Reversing, Full Voltage . V5-T2-10 2 Starters—Single-Phase Non-Reversing, Full Voltage, Bi-Metallic Overload . V5-T2-15 2 Accessories . V5-T2-21 Renewal Parts . V5-T2-30 2 Technical Data and Specifications . V5-T2-34 Relays—Thermal Overload . V5-T2-38 2 C440/XT Electronic Overload Relay . V5-T2-48 2 NEMA Size 1 Contactor 2.2 Space-Savings Series Product Description . V5-T2-67 2 Catalogue Number Selection . V5-T2-68 2 Product Selection . V5-T2-68 Accessories . V5-T2-70 2 Renewal Parts. V5-T2-74 Technical Data and Specifications. V5-T2-75 2 C440/XT Electronic Overload Relay . V5-T2-82 2 2.3 A200 Series 2 NEMA Space-Savings Contactors—Non-Reversing and Reversing . V5-T2-105 Size 1C Contactor Starters—Non-Reversing and Reversing . V5-T2-111 2 Relays—Thermal and Fast Trip . V5-T2-132 Thermal Type B, Class 20, Manual Reset . V5-T2-134 2 Thermal Type A, Class 20, Auto/Manual Reset. V5-T2-137 2 Type FT Fast Trip, Class 10 . V5-T2-140 Heater Selection . V5-T2-143 2 2.4 Solenoids—Alternating Current 2 Product Description . V5-T2-145 Product Selection . V5-T2-146 2 Dimensions . V5-T2-147 2 2.5 Shoe Brakes—AC and DC Magnetic Product Description . V5-T2-148 2 Product Selection . V5-T2-149 2 Dimensions . V5-T2-151 2.6 Reference Data 2 IEC Utilization Categories . V5-T2-153 2 Annex A (informative) . V5-T2-154 Motor Ratings Data . V5-T2-156 2 2 2 2 Volume 5—Power Control Products CA033001EN—January 2017 www.eatoncanada.ca V5-T2-1 NEMA Contactors and Starters 2.1 Freedom Series 2 Freedom Series Contents Description Page 2 Technical Data and Specifications Standards and Certifications . V5-T2-3 2 Catalogue Number Selection . V5-T2-3 Contactors—Non-Reversing and Reversing . V5-T2-4 2 Starters—Three-Phase Non-Reversing and Reversing, Full Voltage . V5-T2-10 2 Starters—Single-Phase Non-Reversing, Full Voltage, Bi-Metallic Overload . V5-T2-15 2 Accessories. V5-T2-21 Renewal Parts . V5-T2-30 2 Technical Data and Specifications . V5-T2-34 Relays—Thermal Overload . V5-T2-38 2 C440/XT Electronic Overload Relay. V5-T2-48 2 2 2 Product Overview Features, Benefits and Functions Freedom Series starters and Freedom NEMA 2 contactors feature a compact, ● ● space-saving design, using Adjustable bimetallic Accessible terminals for 2 state-of-the-art technology ambient compensated easy wiring. Optional and the latest in high overload relays with fingerproof shields 2 strength, impact and interchangeable heater available to prevent temperature resistant packs—available in three electrical shock insulating materials. basic sizes, covering ● Top located coil terminals 2 applications up to convenient and readily 900 hp—reducing the accessible. 45 mm 2 number of different contactor magnet coils contactor/overload relay have three terminals, 2 combinations that have to permitting either top or be stocked. Fixed heater diagonal wiring—easy to 2 overloads are optional replace European or U.S. ● Electronic overload relay style starters or contactors (C440) available as a stand- without changing wiring 2 alone unit and assembled layout with Freedom Contactor ● Designed to meet or 2 ● A full line of snap-on exceed NEMA, UL, CSA, accessories— top and side VDE, BS and other 2 mounted auxiliary contacts, international standards solid-state and pneumatic and listings 2 timers, and so on ● American engineering— ● Straight-through wiring— built by Eaton, using the 2 line lugs at top, load lugs latest in statistical process at bottom control methods to 2 ● Horizontal or vertical produce high quality, mounting on upright panel reliable products 2 for application freedom ● Sized based on standard ● Screw type power NEMA classifications terminals have captive, ● Easy coil change and 2 backed-out self-lifting inspectable/replaceable pressure plates with contacts 2 ± screws—reduced ● Available in open and wiring time NEMA Type 1, 3R, 4/4X 2 and 12 enclosures 2 2 V5-T2-2 Volume 5—Power Control Products CA033001EN—January 2017 www.eatoncanada.ca NEMA Contactors and Starters Freedom Series 2.1 Standards and Certifications 2 ● Standard: designed to ISO 9000 Certification Short Circuit Protection meet or exceed UL, When you turn to Eaton’s Fuses and Inverse-Time 2 NEMA, IEC, CSA, VDE products, you turn to quality. Circuit Breakers may be and BS The International Standards selected per Article 430, ● UL listed: UL File #E1491, Organization (ISO) has Part D of the National 2 Guide #NLDX—Open and established a series of Electrical Code to protect NEMA 1, 4, 12 Enclosed standards acknowledged motor branch circuits from 2 ● CSA Certified: CSA File by 91 industrialized nations fault conditions. If higher #LR353, Class #321104 to bring harmony to the ratings or settings are required 2 Open and NEMA 1 international quest for quality. to start the motor, do not Enclosed The ISO certification process exceed the maximum as listed covers 20 quality system in Exception No. 2, Article 2 elements in design, 430-52. production and installation 2 that must conform to achieve registration. This 2 commitment to quality will result in increased product 2 reliability and total customer satisfaction. 2 2 Catalogue Number Selection 2 Freedom Series 2 A N 1 9 A N 0 A 5E 005 2 Device Type C440 OLR Designation C440 FLA Range 2 A = Starter Standard (FVNR and FVR only) (FVNR and FVR only) C = Contactor E = IEC 5E = Standard feature set NEMA Size 00 2 N = NEMA SEL Reset, SEL Class (10A, 10, 20, 30) 1P6 = 0.33–1.65A 5G = Ground fault feature set 005 =1–5A SEL Reset, SEL Class (10, 20) 020 =4–20A 2 Device Assembly OLR Type NEMA Size 0 Configuration 5 = Contactor only—no overload relay AC Coil Suffix 1P6 = 0.33–1.65A 2 005 =1–5A 70 = Multi-speed 6 = Starter w/C306 bi-metal OLR Suffix Coil Volts and Hertz 1 = Non-reversing 9 = Starter w/C440 electronic 020 =4–20A A = 120/60 or 110/50 5 = Reversing overload NEMA Size 1 2 B = 240/60 or 220/50 C = 480/60 or 440/50 1P6 = 0.33–1.65A D = 600/60 or 550/50 005 =1–5A 2 E = 208/60 020 =4–20A NEMA Enclosure 045 =9–45A 1 H = 277/60 Contactor Frame Size N = Open J = 208 – 240/60 2 NEMA Size 2 2 NEMA Continuous K = 240/50 005 =1–5A Size Amperes For Starters L = 380 – 415/50 020 =4–20A 2 A = 00 9 Starter N = 550/50 045 =9–45A B 3 = 0 18 Mounting Option T = 24/60, 24/50 NEMA Size 3 D= 1 27 U = 24/50 2 G= 2 45 0 = Horizontal V = 32/50 100 = 20–100A K= 3 90 V = Vertical W = 48/60 NEMA Size 4 N= 4 135 For Contactors Only Y = 48/50 140 = 28–140A 2 S= 5 270 2 = Two-pole NEMA Size 5 4 T= 6 540 3 = Three-pole 300 = 60–300A 2 U= 7 810 4 = Four-pole V= 8 1215 5 = Five-pole 2 Notes 1 For contactor only orders, add B to end of Catalogue number if NEMA Size 00–2, 6. 2 2 NEMA Sizes 00 and 0 only. 3 NEMA Sizes 00 and 0 only. Sizes 1–8 are 24/60 only. 2 4 NEMA Size 5 requires the use of CTs with 1-5A OL relay. 2 2 Volume 5—Power Control Products CA033001EN—January 2017 www.eatoncanada.ca V5-T2-3 NEMA Contactors and Starters 2.1 Freedom Series 2 Non-Reversing and Reversing Contactors Contents Description Page 2 Contactors—Non-Reversing and Reversing Product Selection . V5-T2-5 2 Kits and Accessories. V5-T2-6 Renewal Parts Publication Numbers. V5-T2-6 2 Technical Data and Specifications . V5-T2-7 Dimensions. V5-T2-8 2 Starters—Three-Phase Non-Reversing and Reversing, Full Voltage . V5-T2-10 2 Starters—Single-Phase Non-Reversing, Full Voltage, Bi-Metallic Overload . V5-T2-15 2 Accessories . V5-T2-21 Renewal Parts . V5-T2-30 2 Technical Data and Specifications . V5-T2-34 2 Relays—Thermal Overload. V5-T2-38 2 2 Contactors—Non-Reversing and Reversing 2 Product Description Features, Benefits and Functions ● Designed specifically for Non-Reversing Non-Reversing Reversing 2 use in applications ● Holding circuit contact(s) Contactors are most Reversing contactors are requiring NEMA ratings. supplied as standard: commonly used to switch used primarily for reversing Contactors meet or ● Sizes 00–3 have NO 2 motor loads in applications single- or three-phase motors exceed NEMA standards auxiliary contact block where running overcurrent in applications where running ICS 2-1993 mounted on right hand 2 protection is either not overcurrent protection is ● Long life twin break, side (on Size 00, contact required or is provided either not required or is silver cadmium oxide occupies 4th power pole separately. Contactors consist provided separately. They 2 contacts—provide position—no increase of a magnetically actuated consist of two contactors excellent conductivity and in width) switch which can be remotely mechanically and electrically superior resistance to 2 ● Sizes 4–5 have a operated by a pushbutton interlocked to prevent line welding and arc erosion station or pilot device such shorts and energization of NO contact block ● Designed to 3,000,000 2 as a proximity switch, limit both contactors mounted on left side electrical operations at switch, float switch, auxiliary simultaneously.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    158 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us