Subject Index

Subject Index

STP1019-EB/Apr. 1989 Subject Index A Alkylbenzene Benzene, chemical ionization-proton chemical ionization-proton exchange exchange analysis, 40-43 analysis, 42, 44-45 Biomarker analysis, gas chromatography/ Kendrick mass analysis, 188-189 mass spectrometry, 3 metastable spectra, 107-108 Biomarkers, 59-60 n-Alkylbenzenes Buddingtonite, pyrolysis of, 141- GC/MS analysis, 108-109 142 Arabian Heavy asphaltenes, 108- 109 C n-Alkylbenzothiophenes, 4, 108, 115 GC/MS analysis ~oC combinations, Kendrick masses, 182, background, 94-95 185-186 hydrocarbon and sulfur carbon types, CH34S combinations, Kendrick masses, 95, 97-103 182, 185-186 magnified view, 101, 104 Chemical ionization (CI) (see also pyrolysis GC/MS and, 95 Ammonia chemical ionization; homologs, singlek doublet, and Isobutane chemical ionization) multiplet, 105, 108 coal-derived liquids, 145 mass spectra, major isomers, 112- metalloporphyrins, 84-92 115 reagent gas pressure, 138 metastable spectra, 107-108 role in SFC-MS, 21 molecular and fragment ions, 108, SFC-MS interfaces and flow restrictors, 111 9 Alkylindans, chemical ionization-proton sterane analysis, mass spectrometry, 49 exchange analysis, 42, 44-45 Chemical ionization-proton exchange Alkyltetralins, chemical ionization-proton (CIPE), 3 exchange analysis, 42, 44-45 jet fuel analysis, 38-45 Ammonia, oil shale pyrolysis, 133- peak identification, 45 142 CHY software program, ! 85, 188 Ammonia chemical ionization Coal-derived liquids geoporphyrin analysis, 92 chemical ionization-proton exchange metalloporphyrins, 3, 84-85 analysis, 40-43 mass spectra, 86 low-voltage mass spectrometry, 144-153 porphyrin mass spectrometry, 88-92 SFC-MS analyses, 10-21 Arabian heavy asphaltenes Coal extracts n-akylbenzenes, 108-109 LVHRMS-direct insertion probe, 116- n-aklylbenzothiophenes, 95-115 125 Aromatics, hydrotreatment effect, 156- molten-caustic treatment, 117 157 preparation, ! 17 ASTM Test Methods raw versus molten-caustic-treated, D 2425-83, 25 126-131 D 2786-86, 25, 33-37, 164-166, 168 Coal tar, SFC-MS analyses, 7-8, 10-11 Autoscaling, multivariate analysis, Collisionally activated dissociation (CAD) 148 metalloporphyrins, 85 197 Copyright9 by ASTM International www.astm.org 198 FOSSILFUEL MASS SPECTROMETRY Computer programming (see Hardware; GC/MS fossil fuel analysis Software programs) evaluation and reliability, 170 Contamination, tandem mass experimental systems, 162-163 spectrometry, 56, 58 future research, 170-171 Crude oil, sterane traces in, 47-58 hydrocarbon carbon number assignment, 165 D main principles of, 163-170 molecular ion search, 165-166 Deuterium exchange, chemical ionization- need for, 160-162 proton exchange analysis, 40- n-paraffin identification, 163-165 43 quantitation and sorting, 167-170 Diesel fuel structure assignment, 166-167 SFE-MS analysis, 10-21 type analysis, 164 methane CI mass spectra, 10, 13 human expert comparisons, 170-171 Dipyrrole fragments, pyrrole formation, schematic, 161 89-92 Direct fluid injection (DFI) mass spectrometry, 10, 12-15 SFC-MS interfaces and flow restrictors, Factor analysis 9 Factor I spectra, 152, 156 Direct-insertion-probe technique, Factor II spectra, 152, 156 LVHRMS hydrotreatment data, 148, 151-153 Bevier coal extracts, 123-125 Factor spectrum coal-derived materials, 116-125 hydrotreatment data, 148, 152-155 Direct-probe inlet mass spectrometry, 16- time/temperature trends, 153, 155 17 Fast atom bombardment (FAB), 1 DS-55 software system, 119-120 Field ionization (FI), coal-derived liquids, 145 Flame ionization detection CIPE analysis and, 38 ECNCI gas chromatography and, 27 sterane analysis, 49 supercritical fluid chromatography, 5-6 methane-enhanced, 50-5 l Fourier transform infrared spectroscopy Electron impact spectra (FTIR), 134 CIPE analysis and, 39 daughter spectra, 62, 64 G full-scan, 62-63 Electron ionization (EI) Gas chromatography (GC) geoporphyrin analysis, 92 apparatus, 3-m DuraBond system, 26 metalloporphyrin, 3, 84-92 component discrimination, 27-31 mass spectra, 86 flame ionization detection, 27 porphyrin mass spectrometry, 87- fossil fuel analysis, 159-171 88 mass spectrometry (GC/MS) (see Gas SFC-MS interfaces and flow restrictors, chromatography/mass 9 spectrometry) sterane analysis, sample introduction methods, 27-28 daughter mass spectra, 51-52 sterane analysis, 48-49 mass spectra, 49 Gas chromatography/mass spectrometry Electron ionization mass spectrometry (GC/MS) (EIMS), 134 n-alkylbenzothiophenes/n-alkylbenzenes, Expert systems, 159-171 95-115 comparisons with other analytical apparatus used, 26-27 methods, 171 ASTM comparisons, 33-37 future research trends, 170-171 biomarkers, 60 INDEX 199 CIPE analysis and, 39 coal-derived liquids, 145 comparisons with MS/MS, 2 IF-THEN-Else rules, 162 computer hardware and software, 27 Indans, chemical ionization-proton expert systems, 160-162 exchange analysis, 40-43 fuel variations, 34-37 Injection techniques HTA sample introduction methods, 27- area ratio accuracies, 31 31 gas chromatography, 28-31 hydrocarbon analysis, 3 Integrated Two-Stage Liquefaction (ITSL) injection port temperature versus area coal-derived liquids, 144-146 ratios, 27-30 schematic, 145-146 ion summation chromatograms, 27- Ion current instability, direct-insertion- 28 probe techniques, 120-121 jet fuel analysis, 24-37 Ionization techniques, 1-3 limits of detection, 31, 33-34 Isobutane chemical ionization short column and simulated distillation, ammonia determination, 137-138 25-27 ammonia from oil shale pyrolysis, 133- software programs for, 159-171 142 splitless versus on-column injection, 30- ammonia volume versus concentration, 31 149 sterane analysis, 52-53 isobutane fragment monitoring, 138- Geoporphyrins 140 defined, 84-85 quadruple analyzer transmission, EI and ammonia CI analysis, 90 138 reagent gas pressure, 138 H secondary electron multiplier (SEM) gain, 138 Hardware (computer), Hewlett Packard- Interface Buss (HPIB), 135 J Heuristics, expert systems, 161-162 HFR interface, SFC-MS analysis, 15 Jet fuel analysis High Resolution Mass Spectral analysis, CIPE method, 38-45 Kendric masses and, 172-193 coal-derived, 40-43 Hydroaromatics, hydrotreatment effect, GS/MS hydrocarbon-type analysis, 24- 156-157 37 Hydrocarbon carbon number assignment, 165-166 K homologs, coal extracts, 119-120 LVHRM-direct-insertion-probe Kendrick masses, 4 techniques, 124 ~2C mass, 174-175 Hydrocarbon-type analysis (HTA), 3 defect, 175 fuel variations, 34-37 factor, 175 jet fuels, GS/MS, 24-37 high-resolution mass spectrometry and, sample introduction methods, 27- 172-193 28 root mean square errors, 189 versus ASTM test methods, 33-37 Knowledge engineering, 162 Hydronium ion, ammonia determination, 140 L Hydrotreatment effect, 4 average mass spectra, 148-150 Laser desorption, 1-2 coal-derived liquids, 144-153 Liquid chromatography/mass sample identification, 145-146 spectrometry (LC/MS), Hydroxy-polynuclear aromatic 145 hydrocarbons, 20-21 LISP language, 162 200 FOSSILFUEL MASS SPECTROMETRY Low-voltage high-resolution mass Molten-caustic-treated coal extracts, spectrometry (LVHRMS), 4 LVHRM-direct-insertion-probe direct-insertion-probe technique techniques formula class distributions, 123 Bevier coal extracts,. 123-124 summary of compound types, 122- mole percent determinations, 126-131 123 Monoaromatics, hydrocarbon carbon Low-voltage, high-resolution mass numbers, 165-166 spectrometry Monooxygenated compounds, LVHRM- direct-insertion probe and coal-derived direct-insertion-probe techniques, materials, 116-125 124 Low-voltage mass spectrometry MS/MS (see Tandem mass spectrometry) coal-derived liquids, 144-153 Multiple reaction monitoring multivariate analysis and, 4 crude oil extracts used, 60-61, 65 schematic diagram, 147 sterane responses, 65, 67-70 triterpenes, 65, 75-78 M Multivariate analysis, standardization, 148 MAP, n-alkylbenzenes analysis, 95, 97-103 N Marine diesel fuel, SFC-MS analysis, 10, 12 Nitrogen-containing polycyclic aromatic Mass spectrometry (MS) (see also Tandem hydrocarbon (NPAC) mass spectrometry (MS/MS)) LVHRM-direct-insertion-probe n-alkylbenzothiophenes and n- techniques, 124-125 alkylbenzenes, 95-115 mass spectra from, 16, 18-19, 21 apparatus, MAT TSQ45, 26 SFC-MS analysis, 16-17 chemical ionization-proton exchange Nominal mass Z series (NMZ) and, 38-45 first array combinations, 182, 184 coal-derived liquids, 145 rectangular array concept, 174-182 gas chromatography (see Gas unassigned peaks, 175, 180-183 chromatography/mass N-paraffins, expert system identification, spectrometry (GC/MS)) 163-165 jet fuel analysis, 24-37 low-voltage high-resolution (see Low- O voltage high-resolution mass spectrometry (LVHRMS)) Octaethylporphyrin, EI and ammonia CI metalloporphyrins, 84-85 analysis, 86-92 overview, 1 Oil-oil correlation, multiple reaction software programs for, 159-171 monitoring, 65-83 sterane analysis, normal MS, 49-51 Oil shale (see Shale oil) supercritical fluid chromatography (see On-column injection, gas chromatography, Supercritical fluid 30-31 chromatography/mass One-ring aromatic neutrals, Kendric mass spectrometry (SFC/MS)) rectangular array, 175-182 Medium-resolution SIR, 62, 65 On-line mass spectrometry, ammonia Metalloporphyrins from oil shale pyrolysis, 133-142 chemical ionization, 84-92 Organosulfur compounds (see Sulfur) electron ionization, 84-92 Metastable ions, multiple reaction P monitoring, 60-64 Methane chemical ionization, PCI, sterane analysis metalloporphyrins, 84-85 daughter mass spectra, 52-53 Methylene, repeating unit concept, 173 MS/MS, 49 Microbore SFC-MS, 15-21 Petroleum analysis,

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    6 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us