Highly Insulating Window Panel Attachment Retrofit

Highly Insulating Window Panel Attachment Retrofit

Prepared for the General Services Administration By Lawrence Berkeley National Laboratory - Windows and Envelope Materials Group March 2013 Highly Insulating Window Panel Attachment Retrofit Charlie Curcija, Principal Investigator Howdy Goudey Robin Mitchell Erin Dickerhoff The Green Proving Ground program leverages GSA’s real estate portfolio to evaluate innovative sustainable building technologies and practices. Findings are used to support the development of GSA performance specifications and inform decision-making within GSA, other federal agencies, and the real estate industry. The program aims to drive innovation in environmental performance in federal buildings and help lead market transformation through deployment of new technologies. DISCLAIMER This document was prepared as an account of work sponsored by the United States Government. While this document is believed to contain correct information, neither the United States Government nor any agency thereof, nor Lawrence Berkeley National Laboratory, nor any of their employees, makes any warranty, express or implied, or assumes any legal responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by its trade name, trademark, manufacturer, or otherwise, does not constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Lawrence Berkeley National Laboratory. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof or Lawrence Berkeley National Laboratory. The work described in this report was funded by the U.S. General Services Administration [and the Federal Energy Management Program of the U.S. Department of Energy] under interagency agreement number PX0013255, and task order number GS-P-00-12-CY-0046. ACKNOWLEDGEMENTS The demonstration facility agency was the United States General Services Administration, Field Office, Provo, Utah. This project was supported by Kevin Powell, Michael Hobson, Michael Lowell, and Doug Rothgeb, GSA-PBS- Green Proving Ground National Program Team. Special thanks and appreciation to Daniel Wang, United States General Services Administration, Property Manager, Salt Lake City, UT, GSA-PBS-Region 8 of Design & Construction, and the building tenants in the field office in Provo, UT, for their support of this project. For more information contact: Kevin Powell Program Manager, Green Proving Ground Office of the Commissioner, Public Buildings Service U.S. General Services Administration 555 Battery Street, Room 518 San Francisco, CA 94708 Email: [email protected] Highly Insulating Window Panel Retrofit Page i Table of Contents I. Executive Summary ....................................................................................................................................... 1 II. Background ................................................................................................................................................... 3 A. Window Energy Savings Opportunity ................................................................................................... 3 B. State of the Art Window Technology .................................................................................................... 4 III. Project Installation and Evaluation ................................................................................................................ 7 A. Overview of Retrofit Technology .......................................................................................................... 7 B. Demonstration Project Location and Description ............................................................................... 10 C. Test and Instrumentation Plan ........................................................................................................... 12 IV. Project Results/Findings .............................................................................................................................. 16 A. Direct Measurements ........................................................................................................................ 16 B. Modeled Window Performance Results ............................................................................................. 20 C. Framing Effects .................................................................................................................................. 21 D. Potential for Condensation ................................................................................................................ 24 E. Observed Energy Savings ................................................................................................................... 25 F. Annual Energy Simulation Savings ...................................................................................................... 27 G. Payback Optimization ........................................................................................................................ 31 H. Occupant Response Survey ................................................................................................................ 34 I. Associated Observations .................................................................................................................... 37 V. Conclusions and Recommendations ............................................................................................................ 38 VI. Appendices.................................................................................................................................................. 41 A. Technology Specification .................................................................................................................... 41 B. References ......................................................................................................................................... 43 C. Glossary ............................................................................................................................................. 44 Highly Insulating Window Panel Retrofit Page ii I. Executive Summary BACKGROUND Nationwide, the energy savings potential for replacing the existing windows on commercial buildings with high-performance triple pane windows is about 1 quadrillion BTUs (Apte 2006), which equals just over 1% of the total energy consumption by the United States in 2011. One quadrillion BTUs is also known as 1 “quad” and is equivalent to the energy consumed by 5.5 million U.S. households (US EIA 2012). By using insulating window retrofits installed over existing glass and framing systems to achieve performances levels similar to triple glazing, it should be possible to reduce heating and cooling energy use by two thirds of the previous value for typical existing construction, on average. Larger savings can potentially be achieved by retrofitting buildings with the poorest performance windows in the coldest climates. OVERVIEW OF THE TECHNOLOGY This study evaluates a high-performance insulating window retrofit technology that was installed on the interior side of each original single pane glass window in a GSA office building in Provo, Utah. A total of 21 windows were retrofitted with a combined glass surface area of about 231 sq. ft. and a wall-to-window area ratio of 10 to 1. The highly insulating window retrofit product (Hi-R panel) tested is a pre-manufactured, framed window unit featuring three glazing layers that enclose two hermetically sealed Argon filled gaps. The thermal insulating performance of windows resulting from an indoor-outdoor temperature difference, not direct solar gain, is reported as a conductance (U-factor), where a smaller number is a better insulator. The mathematical inverse, the R-value, which is typically used to report thermal performance of walls, is also provided (in IP units) for comparison. When installed over an existing single pane window, the resulting four-layer assembly has a U-factor of 0.14 BTU/hr-ft2-F (R-7.1) at the center of glass, and 0.27 BTU/hr-ft2-F (R-3.7) for the whole window, including the frame. By comparison, the original single pane glass window with an aluminum frame had a U-factor of 0.98 BTU/hr-ft2-F (R-1) for both the center of the glass and the whole window, because the original glass and frame performance are roughly the same. While the four- layer glazing reduces the heat transfer of the central glass area to 1/7 of its previous value, the whole window heat transfer, including the frame effect, is reduced overall to approximately 1/3 the previous value. PROJECT RESULTS/FINDINGS As measured over the winter months with the highest heating load, the total building heating load reduction was 34-41% for the Provo office, following the installation of the Hi-R panel window retrofit. By scaling the measured results by heating degree-day data for the entire year, we can project the annual savings for the retrofit as reduced consumption of natural gas by 108 MBTUs, which leads to reduced carbon dioxide emissions of 6.4 tons. Although this type of retrofit can also result in cooling energy savings, a measurable cooling impact was not apparent in this building. Existing deep window overhangs already provided effective shading that reduced solar heat gain through windows. In addition

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    48 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us