I31-3 Gas Inbuilt Model: I31NG3-R I31LPG3-R

I31-3 Gas Inbuilt Model: I31NG3-R I31LPG3-R

Owners & Installation I31-3 Gas Inbuilt Model: I31NG3-R I31LPG3-R PLEASE KEEP THESE INSTRUCTIONS Manual FOR FUTURE REFERENCE WARNING: FOR YOUR SAFETY Improper installation, adjustment, altera- What to do if you smell gas: tion, service or maintenance can cause Do not try to light any appli- injury or property damage. Refer to this ance LISTINGS AND CODE APPROVALS manual. For assistance or additional in- Do not touch any electrical These gas appliances have been tested in formation consult an authorised installer, switch: do not use any phone accordance with AS4553, NZS 5262 and service agency or the gas supplier. in your building. have been certified by the Australian Gas Immediately call your gas Association for installation and operation as FOR YOUR SAFETY described in these Installation and Operating Do not store or use gasoline or other flam- supplier from a neighbour's Instructions. mable vapours and liquids in the vicinity of phone. Follow the gas sup- this or any other appliance. plier's instructions. Your unit should be serviced annually by If you cannot reach your gas an authorised service person. Installation and service must be performed supplier, call the fire depart- by an authorised installer, service agency or ment. the gas supplier. 918-001h 21 March 2019 REGENCY GAS FIREPLACE INBUILT FIREPLACE TO THE NEW OWNER Congratulations! You are the owner of a state-of-the-art Gas Inbuilt Fireplace by Fireplace Products Interna- tional Ltd.. The Regency Gas Fireplace Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a fireplace, at the flick of a switch. The model I31-3 of this series has been approved by Australian Gas Association for both safety and efficiency. As it also bears our own mark, it prom- ises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace. 40-1/4" (1022mm) 1-3/8" (35mm) 11-3/4" 5/8" 3-3/4" (298mm) (16mm) (95mm) (667mm) (514mm) 26-1/4" 20-1/4" 27-7/8" (708mm) 13-1/2" (343mm) 38mm 2 Regency I31-3 Gas Fireplace Inbuilt TABLE OF CONTENTS REGENCY GAS FIREPLACE INSERT Unit Dimensions ..........................................................2 Operating Instructions Safety Label.................................................................4 Operating Instructions ...............................................16 Lighting Procedure ....................................................16 Installation Shutdown Procedure .................................................16 First Fire ...............................................................16 For Your Safety ............................................................5 Automatic Convection Fan Operation........................16 Specifications ..............................................................5 Normal Operating Sounds of Gas Appliances ...........16 Installation Checklist ....................................................5 Copy of Lighting Instruction Plate ..............................17 Materials Required .....................................................5 Minimum Fireplace Dimension ....................................6 Maintenance Clearances to Combustibles........................................6 Gas Connection ...........................................................6 Maintenance ..............................................................18 Draft Diverter Connection ............................................7 - Gold Plated Trim ...............................................18 Flueing .................................................................7 - Log Replacement ..............................................18 - Combustion & Ventilation ........................................7 - Door Glass Replacement ..................................18 Gas Pressure Test .......................................................7 - Bay Glass Removal ..........................................18 Test for Flue Spillage ...................................................7 - Flush Glass Replacement .................................18 Optional Brick Panel ...................................................8 - Glass Gasket ....................................................19 Log Installation ............................................................8 - Fan Maintenance ..............................................19 Faceplate & Trim .......................................................10 Trouble Shooting ......................................................20 Glass Front Installation - Standard Flush Door (1 panel) ..............................10 Parts List ...............................................................21 - Flush Louvres ........................................................10 - Optional Bay Door (3 panel) .................................. 11 Warranty - Bay Louvres .......................................................... 11 Hampton Cast Faceplate Installation.........................12 Warranty ...............................................................26 Hampton Cast Grill Installation ..................................13 Barossa Curved Front ...............................................14 Optional Remote Control ..........................................15 Optional Wall Thermostat ..........................................15 Wiring Diagram ..........................................................15 Regency I31-3 Gas Fireplace Inbuilt 3 DATA BADGE This is a copy of the label that accompanies DATA BADGE NOTE: Regency units are con- each Regency I31-3 Gas Inbuilt fireplace. We stantly being improved. Check the label on the have printed a copy of the contents here for unit and if there is a difference, the label on the your review. unit is the correct one. Regency Gas Fireplace Model Distributed by: Western Australia: Gas Type NG LPG NG LPG Air Group Australia 28 Division St Model P36-NG P36-LPG I31NG3-R I31LPG3-R Welshpool, WA 6106 Gas Consumption 33mj. 31mj. 31mj. 31mj. Eastern Australia: Manifold Pressure 1.0kPa 2.7kPa .9kPa 2.59kPa Fireplace Products Injector Size 1x#37 1x#52 1x#37 1x#52 Australia Pty. Ltd. 1 Conquest Way 2.65mm 1.6mm 2.65mm 1.6mm Hallam, VIC 3803 AGA 5815 G AGA 5498 G To be installed by an authorised person in accordance with installation instructions provided with the appliance. AS4553 Serial Electrical Conforms to AS3100 240V 50Hz 1.0 amp Max. N2134 Number 241 908-062h Part #: 908-062h Size: 100% Colour: black on silver Sept. 22/09: updated standard (removed 2000 from As4553) Feb. 4/10: Updated distributor Sept. 2012:Updated standard. Dec. 17/13:Rev. G Adjusted positioning of standard lettering and E. Aus address Nov. 7/16: updated I31 naming conformity (Australia Only) 4 Regency I31-3 Gas Fireplace Inbuilt INSTALLATION that control compartments, burners and IMPORTANT: circulating air passageways of the appliance 7) Install the optional brick panels. See page SAVE THESE be kept clean and free from excessive lint 8. from carpeting. INSTRUCTIONS 8) Install the log set. See page 8. 4) See general construction and assembly The Regency Gas Fireplace must be installed instructions. This appliance may only be in- 9) Assemble and install the faceplate and trim. in accordance with these instructions. Carefully stalled in a flued, non-combustible fireplace. See page 10. read all the instructions in this manual first. The appliance and flue should be enclosed when installed or passing through a living 10) Install the glass front (page 10) and optional Note: Failure to follow these instructions area, where children may come in contact Bay Front (page 11). could cause a malfunction of the with it. heater which could result in death, 11) Install both louvres, flush (page 10) or Bay serious bodily injury, and/or prop- 5) Always connect this space heater to a chim- (page 11). erty damage. Failure to follow these ney and flue to the outside of the building instructions may also void your fire envelope. Never flue to another room. Make 12) Install Optional Remote Control and Optional insurance and/or warranty. sure that the flue is properly sized and is of Wall Thermostat, page 15. adequate height to provide the proper draft. 13) Final check: Before leaving this unit with the 6) Inspect the flueing system annually for customer, the installer must ensure that the FOR YOUR SAFETY blockage and any signs of deterioration. appliance is firing correctly. This includes: This appliance requires air for proper combus- Any safety glass removed for servicing must Clocking the appliance to ensure the tion. Always provide adequate combustion and 7) a) be replaced prior to operating the appliance. correct firing rate. ventilation air. Follow instructions and informa- tion in the current AS5601-2004, NZS 5261 To prevent injury, do not allow anyone who Adjusting the primary air, if required, to or local codes. Consult the "authority having 8) b) is unfamiliar with the operation to use the ensure that the flame does not carbon. jurisdiction" to determine the need for a permit fireplace. See page 7. prior to starting the installation. 9) Installer must mechanically attach the sup- c) Ensuring that the appliance is flueing plied label to the inside of the firebox of the correctly. See page 7. GAS PIPE TESTING fireplace into which the gas fireplace insert is installed. The appliance must be isolated from the gas supply piping system by closing its individual “WARNING: This fireplace has been converted manual shutoff

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    36 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us