Optical Measurements for Ramjet Engine Development

Optical Measurements for Ramjet Engine Development

ROLAND E. LEE, ROBERT TURNER, and RICHARD C. BENSON OPTICAL MEASUREMENTS FOR RAMJET ENGINE DEVELOPMENT Two optical instruments, the laser anemometer and the coherent anti-Stokes Raman scattering (CARS) spectrometer, were recently studied at APL's Propulsion Research Laboratory for use as combustion diagnostic tools. Recent test results of the laser anemometer used in a typical exhaust flow environment of a combustion chamber and of CARS in graphite surface oxidation studies are discussed. INTRODUCTION nautics Division, in collaboration with the Research Advanced propulsion systems involve highly com­ Center, is currently reviewing and test-evaluating se­ plex combustion flow processes. Extensive and accu­ lected optical instruments for use in supersonic ram­ rate flowfield measurements can help to guide and jet combustion flow field measurements. Figure 1 lists support engine development. For example, in the hy­ the techniques considered and the flow parameters personic dual-combustor ramjet, the subsonic com­ they are expected to measure. In some cases, an inter­ bustion chamber operating at fuel-rich conditions mediate parameter is used to obtain the desired flow generates a complex multiphase combustion flow parameter; e.g., the laser anemometer measures par­ comprising liquid fuel droplets, soot particles, and ticle velocity, and the gas flow velocity is deduced reacting gases. The complexity of this flow is intensi­ from modeling of particle drag. fied by its subsequent downstream interaction with At the onset of this program, there was very little air at supersonic speeds. In such reacting flows, con­ information on the size, number density, or index of ventional mechanical probes can disturb the local refraction of particles generated by a fuel-rich hydro­ flow environment as well as be subjected to impact carbon combustor. The first two instruments for and thermal damage. Optical instruments that have measuring particle size were selected on the basis of been developed and used in laboratory experiments laser light transmission at two wavelengths and laser of less complex combustion flows avoid these diffi­ light scattering at two viewing angles. They were culties. However, their application in the harsh flow abandoned early in the program because analysis environment of ramjet engine combustion is more showed that the upper range of particle sizes of inter­ difficult and needs to be approached cautiously. In est could not be measured. Follow-on evaluation and contrast to mechanical probes, optical instruments testing showed the laser anemometer and Raman generally are nonintrusive; produce minimum flow spectrometer to be viable instruments that could disturbance; have a faster response, higher data rate withstand the hostile engine-testing environment and capability, and better spatial resolution; and, in some provide data on a number of the pertinent flow pa­ cases, can measure more than one flow parameter per rameters. The laser anemometer observes laser light instrument. scattered by particulates embedded in the flow to de­ Flow modeling requires accurate flowfield mea­ duce the particle and flow velocities, the particle size, surements of stream velocity, temperature and pres­ and the particle number density. The Raman spec­ sure distributions, and, when chemical reactions are trometer relates the laser light scattered by molecules present, the chemical species concentration distribu­ in the combustion medium to flow temperature and tions. For a reacting flow containing a considerable gaseous species concentrations. amount of particulates, the characteristics and distri­ The evaluation of the laser anemometer instrument butions of these particles need to be measured. The included: (a) analysis with laser light scattering (Mie particulate flow is important because it can strongly theory) and light diffraction computer programs; (b) affect both the performance of optical diagnostic de­ calibration with a cold-air supersonic flow (Mach vices and the combustion efficiency. In relatively 3.5) with controlled particle seeding; and (c) actual clean combustion flows, such as most laboratory measurements in a small-scale combustor that can be flames, the particulates are generally of submicro­ operated at pressures up to 4.5 atmospheres, inlet air meter size. In the fuel-rich ramjet flows, however, temperatures from 650 to 870 K, and fuel-air equi­ soot particles and unburned fuel droplets can extend valence ratios between 0.8 and 4.0, using lP-5 fuel. the particle size range from sub micrometer size to as large as 50 micrometers. PARTICLE SIZING In principle, all of the above flow parameters may Various optical techniques have been developed be determined by optical instruments. APL's Aero- that use scattered light to measure the micrometer- 196 Johns Hopkins A PL Technical Digest Flow parameters Intermediate Techniques parameters Laser light Particulate transmission size Laser light Particulate scattering number density Laser Flow Particle velocity anemometry velocity Velocity lag Figure 1 - Optical flow diagnostic Flow parameters and techniques. temperature Flow Species Raman constituents properties scattering Species concentration Top view 90 ~250 mm~250 mml 0mm I focal length I t Flow 00 ? Figure 2 - Laser Doppler velo­ cimeter optical configuration. Photomultiplier Side view 7~L-~_~~\1 size particles found in combustion experiments. In tenuation of a iaser anemometer beam produced by general, all such techniques make assumptions about particles smaller than 100 micrometers. the particle size distribution, particle shape, index of Figure 2 is a schematic diagram of the Thermo­ refraction, and size relative to the wavelength of the Systems, Inc., laser anemometer, which uses a 5-mil­ light source. Some methods use relative amplitude liwatt helium-neon laser, configured for forward 0 measurements; others use absolute measurements. scattering at an elevation angle of 5.8 • The two laser Some observe the signal from a single particle; others anemometer beams cross at an angle of 2 0 to produce observe the signal produced by a number of particles. an ellipsoidal scattering volume. The measured signal The actual method chosen depends to a large extent is a function of a particle's position in each beam; as on the parameters to be determined and the adapt­ a result, constructive and destructive interference can ability of the instrument to the particular applica­ occur as the particle moves through the beams. It is tion. A standard dual-beam laser anemometer, nor­ often convenient to think of the particle as being illu­ mally used to measure particle velocity, was adapted minated by light and dark fringes, with a spacing of to provide a simultaneous measurement of particle 17.6 micrometers in this case. The minor axis of the size (in the range of 3 to about 100 micrometers) and scattering volume, in the direction of flow, is 250 mi­ speed (550 to 1400 meters per second), the density of crometers; the major axis, perpendicular to the flow, particles greater than about 1 micrometer, and the at- is 2 millimeters. A 250-micrometer aperture in the Volume 4, N umber 3, 1983 197 R. E. Lee et al. - Optical Measurements/or Ramjet Engine Development collection optics limits the field of view at the center References 1 through 5 describe aspects of the vis­ of the region to 16 fringes. Particles moving at speeds ibility and scattered light measurements that are re­ of 550 to 1400 meters per second will produce scat­ levant to the work described here. tered light pulses from 0.5 to 0.2 microseconds wide Particle sizing by means of the signal visibility is of that are modulated at frequencies from 30 to 80 recent origin, and there has been considerable discus­ megahertz. Figure 3 is a photograph of the laser ane­ sion about its interpretation and application. The vis­ mometer instrument configured for use in the full­ ibility and intensity techniques are both extremely scale ramjet engine combustor. sensitive to the f number of the collection optics and The size of the particle producing the scattered to their location relative to the incident laser beams. light can be derived from the signal visibility (JI), In fact, the visibility and intensity dependence on which is the ratio of the depth of the modulation particle diameter can be tailored by the proper choice of the scattered signal to the mean amplitude of scattering angle and collection aperture. Because [V = (1 max -I min )/(/max + I min ), where I max and I min of this, it is important that the instrument be calibrat­ are the maximum and minimum of the light inten- ed and also that its response function be calculated sities], and from the mean amplitude of the signal for the conditions actually used. directly. The two methods for determining particle Visibility curves computed for spherical particles size are complementary. With the present laser are shown in Fig. 4 for three conditions. Curve A is anemometer, the intensity of the light scattered by calculated for the collection optics centered between small particles « 3 micrometers) is low, but the the laser anemometer beams and in the plane of the visibility is high (about 1); the intensity of light scat­ beams. The visibility is approximated by: tered by large particles (> 20 micrometers) is large, but the visibility is low (less than 0.3). The intensity measurement is absolute; it generally increases monotonically with particle size and can have a large dynamic range. Visibility is a relative measurement, where J , (7rD p / OJ) is the first -order Bessel function of and because the particle size can be multivalued for a (7rD p/oj ), D p is the particle diameter, and OJ is the fr­ given visibility, the dynamic range is generally less inge spacing.' Curve B is calculated using the stan­ than 10. This can present a problem in its application dard diffraction approximation for the detector if the size range of interest is not defined beforehand. mounted 5.8 0 above the plane of the two beams. Cal- Prism Beam splitter, reducer, and focusing optics Figure 3 - Photograph of the la­ ser Doppler velocimeter mounted on motorized two-component traverse.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    9 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us