INTEGRATED CONTROL SYSTEM NETWORK SOLUTIONS FOR SEAMLEss CONNECTION BETWEEN VRV® AND BMS SYSTEMS BACnet Interface www.daikin.eu MAIN FEATURES 1. Bacnet Interface 2. Open netwOrk IntegratIOn > Precise and efficient monitoring and control of VRV® > The Daikin BACnet adapter requires no additional and HRV systems. Also Split and Sky Air units can interfaces for connection to BACnet networks be connected via an optional interface adapter equipment and building control systems. BACnet > Flexible, multi purpose system networks are recognised worldwide as the standard > Control mechanism is BACnet within the building controls industry. BACnet > Provides easy integration into building manage- data communication protocol makes it possible ment systems (BMS) including management of all to control access, energy management, fire / building installations in remote control or interlocked life / safety, HVAC and lighting etc. control. BMS DMS502A51 DIII- NET DAM602B51 / 52 Local Control (Intelligent Manager) non-standard BACnet ® Interface required VRV Outdoor unit HRV ETHERNET / Remote Control BACNET DAIKIN A / C INFRASTRUCTURE BUILDING CONTROL Fire alarm Security Power supply facility Pump Lighting Elevator NETWORK 2 3. QuIck and easy InstallatIOn 7. functIOns > The open protocol specification gives local system monitoring integrators complete design freedom. Moreover, > Air conditioning status monitoring: 128 groups of the ability to combine individual items of equipment indoor units and 20 outdoor systems. into BACnet networks reduces the time and costs (Max 256 groups of indoor units and 40 outdoor required for wiring work. systems, when optional DIII board is added)1 > Indoor unit error monitoring 4. unlImIted sIte sIze > Indoor (air inlet) temperature monitoring > Filter sign monitoring > The network adapter can be connected to 128 > Thermostat status groups (256 with optional accessory). Maximum > Compressor operation status value of BACnet Interface is set by BACnet BMS. > Indoor fan operation > Heater operation 5. rohs cOmplIance > Air direction monitoring > Air flow rate monitoring > Restriction of Hazardous Substances in electrical and > Forced thermostat off / on monitoring electronic equipment (2002 / 95 / EC). > Alarm sign > Hazardous substances include Lead (Pb), Cadmium > PPD data2 (Cd), Hexavalent Chromium (Cr6+), Mercury (Hg), The transmission of VRV® PPD Polybrominated biphenyls (PBB), Polybrominated (power proportional distribution) data is possible diphenylether (PBDE). by BACnet communication for BMS system. > Although RoHS regulations are only applicable to small and large household equipment, Daikin’s control, operation and settings environmental policy nevertheless ensures that VRV®III will be totally in line with RoHS. > Start / stop control > Temperature adjustment mode setting 6. specIfIcatIOns Of cOmmunIcatIOn > Remote control setting > Temperature setting Objects > Filter sign reset > Indoor unit mode setting > Analog input > Air direction setting > Analog value > Air flow rate setting > Binary input > Forced thermostat off / on setting > Binary output > Energy efficiency command > Binary value (setting temperature shift) > Multistate input > Forced OFF setting > Multistate output > Subgroup adress control operation rejection functionality > Gateway LED display for operation and malfunction detection > Monitoring > Commanding 1 Optional DIII board (DAM411B51) > Alarming 2 Optional Di board (DAM412B51) is required datalink > Ethernet (IEEE802.3) > BACnet / IP 3 8. cOmpatIBIlIty wIth leadIng Bms systems, a.O.: manufacturer type manufacturer type Andover Controls - Continuum ver. 1.6 1.6 Siemens - System 600 Apogee Insight V3.2 Cimetrics Sauter - OPC Server Siemens - System 600 Apogee Insight V3.4 Honeywell - EBI V2.0 Siemens - Desigo Insight V1.01 Iconix Sauter - OPC Server Siemens - PX Desigo Insight V2.2 Invensys (Sacthwell) Polar Soft - System Manager TAC Pacific - OPC Server - BACdoor Trane - Tracer Summit Johnson Controls - Metasys BSI V9.01c Trend Johnson Controls - Metasys N30 Tridium - Niagara Framework 2.301.321.v1 Priva Trilogy Reliable Systems - Mach Compatibility can be checked with a Joint Matching Test before installation. For more information contact your sales representative. SPECIFICATIONS Item descrIptIOn BACnet Interface DMS502A51 Up to 128 groups BACnet transmission ASHRAE135 (IEEE802.3) BACnet / IP Conformance class3 Power supply 1~ AC, 100 to 240V, ± 10% at 50 / 60Hz Power consumption 20W max. Dimensions (H x W x D) mm 263x275x81.5 Weight kg ± 3 Ambient condition -10°C to 50°C within humidity range between 0% and 98% (no condensation) Insulation resistance At least 50M at 500VDC ACCESSORIES Item descrIptIOn DIII board DAM411B51 Extension of 2 x DIII lines (2 x 64) indoor groups Optional Di board DAM412B51 In case of PPD to provide up to 12 pulse input points KRP928B2S For connection to Split units Interface adapters DTA102A52 For connection to R-22 / R-407C Sky Air units DTA112B51 For connection to R-410A Sky Air units Daikin’s unique position as a manufacturer of Daikin Europe N.V. is approved by LRQA for its Quality The present leaflet is drawn up by way of information only and air conditioning equipment, compressors and Management System in accordance with the ISO9001 does not constitute an offer binding upon Daikin Europe N.V.. Daikin refrigerants has led to its close involvement in standard. ISO9001 pertains to quality assurance re- Europe N.V. has compiled the content of this leaflet to the best environmental issues. garding design, development, manufacturing as well of its knowledge. No express or implied warranty is given for the For several years Daikin has had the intention as to services related to the product. completeness, accuracy, reliability or fitness for particular purpose to become a leader in the provision of products of its content and the products and services presented therein. that have limited impact on the environment. Specifications are subject to change without prior notice. Daikin This challenge demands the eco design and Europe N.V. explicitly rejects any liability for any direct or indirect development of a wide range of products and ISO14001 assures an effective environmental man- damage, in the broadest sense, arising from or related to the use an energy management system, resulting in agement system in order to help protect human and/or interpretation of this leaflet. All content is copyrighted by energy conservation and a reduction of waste. health and the environment from the potential impact Daikin Europe N.V. of our activities, products and services and to assist in maintaining and improving the quality of the en- m vironment. -8400 Oostende Daikin units comply with the European regulations that guarantee the safety of the product. Daikin products are distributed by: Daikin © VRV® products are not within the scope of the EPL08-304 Eurovent certification programme. Naamloze Vennootschap Zandvoordestraat 300 ECPEN09-304 • XXX • 02/09 • Copyright Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B B-8400 Oostende, Belgium The present publication supersedes Printed on non-chlorinated paper. Prepared by La Movida, Belgiu www.daikin.eu FSC BTW: BE 0412 120 336 RPR Oostende.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages4 Page
-
File Size-