sensors Review State-of-the-Art Mobile Radiation Detection Systems for Different Scenarios Luís Marques 1,* , Alberto Vale 2 and Pedro Vaz 3 1 Centro de Investigação da Academia da Força Aérea, Academia da Força Aérea, Instituto Universitário Militar, Granja do Marquês, 2715-021 Pêro Pinheiro, Portugal 2 Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais 1, 1049-001 Lisboa, Portugal; [email protected] 3 Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, Estrada Nacional 10 (km 139.7), 2695-066 Bobadela, Portugal; [email protected] * Correspondence: [email protected] Abstract: In the last decade, the development of more compact and lightweight radiation detection systems led to their application in handheld and small unmanned systems, particularly air-based platforms. Examples of improvements are: the use of silicon photomultiplier-based scintillators, new scintillating crystals, compact dual-mode detectors (gamma/neutron), data fusion, mobile sensor net- works, cooperative detection and search. Gamma cameras and dual-particle cameras are increasingly being used for source location. This study reviews and discusses the research advancements in the field of gamma-ray and neutron measurements using mobile radiation detection systems since the Fukushima nuclear accident. Four scenarios are considered: radiological and nuclear accidents and emergencies; illicit traffic of special nuclear materials and radioactive materials; nuclear, accelerator, targets, and irradiation facilities; and naturally occurring radioactive materials monitoring-related activities. The work presented in this paper aims to: compile and review information on the radiation detection systems, contextual sensors and platforms used for each scenario; assess their advantages and limitations, looking prospectively to new research and challenges in the field; and support the decision making of national radioprotection agencies and response teams in respect to adequate Citation: Marques, L.; Vale, A.; detection system for each scenario. For that, an extensive literature review was conducted. Vaz, P. State-of-the-Art Mobile Radiation Detection Systems Keywords: mobile radiation detection systems; NORM; radiological emergencies; nuclear accidents; for Different Scenarios. Sensors 2021, illicit trafficking; accelerators; targets and irradiation facilities; gamma and neutron detectors 21, 1051. https://doi.org/10.3390/ s21041051 Academic Editor: Kelum Gamage 1. Introduction Received: 24 December 2020 Accepted: 31 January 2021 Radioactive materials, radioactive sources, and radiation sources are ubiquitous; Published: 4 February 2021 they are used in practically all sectors, made of different radionuclides, emit different types of ionizing radiation (gamma rays, alpha and beta particles, neutrons), and are Publisher’s Note: MDPI stays neu- characterized by their activity (number of disintegrations per second). Special nuclear tral with regard to jurisdictional clai- materials (SNM) are present in different civilian and military facilities, namely along ms in published maps and institutio- the nuclear fuel cycle (nuclear fission reactors for electricity production, nuclear fuel nal affiliations. fabrication, re-processing and storage facilities, etc.) and in nuclear propulsion vessels (namely submarines and carriers). Concerns about potential malevolent acts involving illicit trafficking of radioactive ma- terials and SNM have increased with the heightened awareness of international terrorism Copyright: © 2021 by the authors. Li- censee MDPI, Basel, Switzerland. where a variety of radiological and nuclear (RN) disaster scenarios could occur includ- This article is an open access article ing threats in urban areas. An example of a non-precedent terrorist act which showed distributed under the terms and con- the terrorists’ ability and willingness to use any means to achieve their goals, was the ditions of the Creative Commons At- attack to the World Trade Center towers (11 September 2001). This event changed the tribution (CC BY) license (https:// paradigm of security and defense worldwide. Another example, now related to the malev- creativecommons.org/licenses/by/ olent use of radioactive material, was the poisoning of Alexander Litvinenko (2006) with 4.0/). polonium-210 [1]. Sensors 2021, 21, 1051. https://doi.org/10.3390/s21041051 https://www.mdpi.com/journal/sensors Sensors 2021, 21, 1051 2 of 65 According to the International Atomic Energy Agency (IAEA) [2], between 1993 and 2019, a total of 3686 incidents, of which 290 involved a confirmed or likely act of trafficking or malicious use, are reported in the illegal traffic database. Other incidents reported in the IAEA database related to safety and security issues associated to radioactive materials involve, inter alia, theft or loss of radioactive sources, unauthorized disposal (sources entering the scrap metal industry), unauthorized shipment of contaminated scrap metal, and the discovery of radioactive sources (orphan sources, out of regulatory control). Radiation portal monitors (RPM) are often used for the prevention of illicit traffic of SNM and radioactive materials, as well as the inadvertent movement of radioactive material. They are located at appropriate checkpoints (e.g., border crossings, airports and seaports) to measure gamma and neutron radiation. Other radiation detection equipment are personal radiation detectors (PRDs) used by front line officers (FLO), hand-held gamma and neutron search detectors, and hand-held radionuclide identification devices. Hand- held instruments can be used as primary detection systems (greater flexibility), or as a secondary search device, for example, to validate a reading from an RPM or PRD [3]. Due to the many potential entryways or transportation modes in a country [4] and inherent difficulty to detect such materials, particularly SNM (normally weak sources, possibly shielded or masked) [5], it is necessary to improve the detection probability to reduce the wrongdoer’s success. The use of portable radiation portal monitors (PRPM), helped to mitigate the lack of devices in other strategic points (depending on the potential threats). Since the a priori location of the PRPMs is unknown, it has also a deterrence effect on potential terrorist acts. However, the "portability" of these devices only means that they can be disassembled into a case for the subsequent transport. The PRPM are normally made with plastic scintillation detectors and can also be used for RN accidents and emergencies (people and vehicles monitoring) [6]. Considering other detection strategies, Cazalas [7] suggested an RN threat detection solution based on a network of radiation detectors at existing road traffic-monitoring system locations (e.g., stop light or red light cameras), while Coogan et al. [4] concluded that mobile radiation detection (MRD) technology with at least one-tenth of the RPM efficiency can have the same or greater impact on the wrongdoer’s success rate. MRDs have the advantage of performing discrete operations and can be deployed to major thoroughfares or to protect a potential target. However, there is a lower control over the geometry, and the MRD performance is highly dependent on their placement. In the same way, to monitor an unintended release of radionuclides, as is the case of a nuclear reactor accident, there are fixed online radiation monitoring systems in the vicinity of the power plant. However, the information gathered by these devices are confined to their location and, in the situation of a natural disaster, like happened in Fukushima, these detectors may fail [8]. This can lead to a lack of information about the radiation levels and consequently in bad, inaccurate, and delayed decisions. The rapid deployment of an MRD system can help to monitor locations not covered by the fixed network or be the main detection system in an RN event [9], for example, to evaluate the activity and direction of the radioactive plume spread on the ground (due to fallout) or in the air (e.g., using an air sampler). This mobility allows covererage of large areas and reduction of survey times. Other scenarios where it is important the use of mobile detection systems are: (i) areas with high concentration of naturally occurring radioactive materials (NORMs), normally associated with large survey areas and dose rates near background radiation, and (ii) the inspection, maintenance and repair activities in nuclear energy facilities, particle acceler- ators, targets, and irradiation facilities, characterized by dose rates ranging from low to high, and, eventually, the presence of high magnetic fields and high temperatures. The use of mobile detection systems may allow to improve the detection efficiency of RN materials by decreasing the distance between detector and source and the effects of air or materials’ attenuation. Sensors 2021, 21, 1051 3 of 65 For each scenario described, one might be interested in the location, identification, and quantification of a radioactive source or the mapping of a contaminated area. Due to their long range in air, gamma-rays and neutrons are preferable indicated for mobile detection systems. This review article encompasses mobile detection systems carried by a person (e.g., handheld and backpack equipment), as well as detectors coupled to ground-based vehicles (e.g., trucks, vans, and cars) and air-based vehicles, like fixed-wing or rotatory
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages65 Page
-
File Size-