Touch Heat and System Installation Guide

Touch Heat and System Installation Guide

Installation guide Wireless room thermostat with hot water control (DHW & single zone CH) Logic Heat H / Logic Max Heat H / Logic System S / Logic Max System S / Vogue System / Vogue Max System Ideal Touch kit contents • Touch thermostat • Batteries (AA) • Mounting bracket cover • Screws and plugs • Mounting bracket • Instructions • Desktop stand • SAP registration label • Ideal relay transceiver Introduction Welcome to the Ideal Touch heat and system guide. This guide is designed to lead you through the installation and Ideal relay transceiver setup of the Ideal Touch. It is advisable to read through all steps before The Ideal relay transceiver provides The thermostat connects to the relay starting the installation. communication between the boiler, transceiver via a wireless RF connection. thermostat and zone valves. A user guide and FAQs can be found at The relay transceiver should be located www.idealboilers.com. The boiler connects to the relay near the existing wiring centre. transceiver via an opentherm wire. The Ideal Touch Heat and System thermostat must be installed by a Gas Safe Registered Engineer. NOTE: All electrical installation work should be carried out by a suitably Read the instructions carefully. qualified electrician or other competent person. Failure to follow these instructions can damage the product or cause a Disconnect electricity supply to the appliance and heating system before hazardous condition. installing the transceiver. Merely switching the boiler to OFF will still leave a live feed to the boiler. ErP Class V as standard. Class VI with an Notes on opentherm wiring outside sensor. The opentherm wire must be connected For routing of cable outside it is Contribution to seasonal space heating energy efficiency: from the relay transceiver to the boiler. dependent upon the application, however cables can be run externally 3% (Class V) A separation of 10mm must be achieved inside trunking. 4% (Class VI) between the opentherm wiring and 230V wiring. Do not run this cable adjacent to mains voltage supply cables. Use 0.5mmsq heat resistant flex. 3 Installation of Ideal relay transceiver 1. Isolate power to boiler and heating system. 4. Make connections as in the diagrams below (except the opentherm wiring - see next steps overleaf). Secure the wires in place using the cable clamps 2. Remove the cover of the relay transceiver and screw the base to the wall, provided. directly above the existing system wiring if possible. If a frost thermostat is connected it should be from live to connection 8 (C/S On) 3. Disconnect and dispose of the wiring to the existing two channel timer and room thermostat. 5. Power to the boiler and heating system should remain isolated. Ideal relay transceiver wiring (Y plan diagram) Ideal relay transceiver wiring (S plan diagram) Relay Transceiver R/S - Room Stat Relay Transceiver R/S - Room Stat HW - Hot Water HW - Hot Water C/S - Cylinder Stat C/S - Cylinder Stat Boiler Boiler opentherm opentherm connector connector WEATHER WEATHER OPENTHERM COMPENSATION OPENTHERM COMPENSATION 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 wiring Opentherm Wiring Opentherm centre centre (not (not supplied) supplied) L L Pump N br N (if external to boiler) E Cylinder E Stat g/y KEY w g/y bl gr gr bl 1 C bl - blue KEY CH br - brown or Cylinder valve g/y - green/yellow Stat bl - blue gr - grey gr bl g/y br or 1 br - brown or - orange g/y - green/yellow Y plan valve C 2 gr - grey DHW or - orange valve Pump or w - white (if external to boiler) *Where the Ideal Touch kit is being fitted to an existing installation (S or Y plan), the wire should then be connected into the SL1 L-IN connection at the boiler†. connecting any SL IN on the boiler requires disconnecting and making safe. A link wire For further details refer to the boiler installation and sevicing instructions. †Logic Heat H, Logic System S, Vogue Gen2 System 4 5 Boiler opentherm wiring - Logic Boiler opentherm wiring - Vogue 1 Remove boiler front panel by 2 Hinge down the control panel. 1 Loosen the two screws on 2 Hinge down the control panel. removing two screws. the front panel and release Release the edge clips to Remove screw and release catches at rear. Remove the hinge open the cover. the clip. front panel + / - not relevant + / - not relevant here as opentherm here as opentherm connection is not connection is not polarity specific polarity specific OPENTHERM WEATHER OPENTHERM WEATHER COMPENSATION COMPENSATION Relay transceiver Boiler control box Relay transceiver Boiler control box Connect two wires from the boiler opentherm terminal strip to the opentherm Connect two wires from the boiler opentherm terminal strip to the opentherm 3 3 connections in the relay transceiver. connections in the relay transceiver. Maintain 10mm separation between the mains cable and the opentherm cables. Maintain 10mm separation between the mains cable and the opentherm cables. Replace the PCB cover and boiler front panel. Replace the PCB cover and boiler front panel. Replace transceiver cover. Replace transceiver cover. Do not switch power on. Do not switch power on. 6 7 Thermostat location guidelines Installation In-between the Ideal relay transceiver and the Touch thermostat there must be: 5 Wait for the screen shown on the • Less than 20 metres left to be displayed. (In the unlikely • No more than a total of 3 walls and ceilings event that this screen is not shown • No large metallic objects (e.g. American fridge/freezer) CONNECTING TO within 20 seconds, electrically • No large mirrors or windows BOILER isolate the boiler and heating • No walls running along the RF path system, remove one battery and The Touch thermostat must not be within 1 metre of a wifi booster / router and repeat from step 2.) should not be placed near draughts, in direct sunlight or near heat sources. Set system time 20.5 6 When successfully connected the Thermostat installation screen shown on the left will be 00 00 displayed. Set the 24hr clock, then select “DONE”. DONE F Set system date BACK U S E 20.5 7 Set the date, then select “DONE”. MON 10:20 If the screen goes blank before set up is complete, tap the screen 01 01 18 and select MENU to access Help & 1 Using a flat bladed 2 Turn electrical power 3 Immediately insert the Settings to set time and date. screwdriver remove the back on to the boiler and fourth battery into ZONE 1 back cover from the heating system. the thermostat. DONE Touch thermostat and insert only 3 batteries. 20.5 8 When set up is complete the screen 4 Hold the thermostat Transceiver will go blank. MON 10:20 2M ZONE 1 approx 2 metres O On Auto away from the relay transceiver. O To attachOn the thermostat to the wall bracket or desktop stand locate the thermostat Auto into the 3 lugs and slide downwards until it clicks. 8 9 Ideal relay transceiver Battery replacement Below are the descriptions of each light on the front of the Ideal relay transceiver. Batteries should operate for approximately 18 to 24 months. Only good quality When illuminated green; alkaline batteries are to be used. If the batteries run out then central heating and hot water will continue to operate 1 RF connection during the set time periods but room temperature control will become less accurate. The relay transceiver is connected to thermostat. 1 Un-clip the thermostat from its cradle by sliding the Touch thermostat upwards. 2 Power Power is being supplied to the relay transceiver. 2 Using a flat bladed screwdriver, remove the rear cover. 3 Opentherm connection 3 Replace batteries and refit battery Opentherm connection to the boiler is working correctly. cover. Note. normal operation is indicated by all three green lights being illuminated. 1 2 3 10 11 Using the Ideal Touch thermostat Troubleshooting FAULT ACTION Central Heating will not switch Check that central heating is set to be ON or is in a ON programmed on period or the override is On Check that the target room temperature is set to be higher than Rotate to boost OVERRIDE HEATING OVERRIDE HOT WATER the actual room temperature temperature HEATING SCHEDULE HOT WATER SCHEDULE Check that the power to the boiler is switched on. Tap to access main menu For Logic boilers ensure that the mode knob is on. Flame symbol For Vogue system boilers ensure that the and knobs are indicates heating on not rotated fully anti-clockwise. Check that the light on the relay transceiver is on, if not check there is mains supply to the relay transceiver. If is shown on the room thermostat, and when the screen is pressed the message zone 1 fault is shown then either the room thermostat is too far away from the relay transceiver or there is unsuitable material in between the relay transceiver and the room thermostat. Refer to location guidelines on page 8. Change the batteries in the room thermostat. If the relay transceiver light is off then check if the wires from the relay transceiver to the boiler and then onto the boiler PCB are securely connected. Check that there is 230V to the zone valve (from relay transceiver R/S On connection). If no response, to previous actions, isolate power to boiler and heating system and return to step 1 page 8. Tap to change Tap to change Central Heating heating hot water will not switch Check that central heating is set to OFF or is in a operating mode operating mode OFF programmed Off period and that the override is off.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    9 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us