Micro Rem and Micro Sievert Survey Frequently Asked Questions

Micro Rem and Micro Sievert Survey Frequently Asked Questions

Thermo Fisher Scientific Micro Rem and Micro Sievert Survey Frequently Asked Questions Question: What is the Micro Rem and Micro Sievert Survey used for? Answer: The Micro Rem and Micro Sievert models are portable survey meters for applications where accurate dose rate measurements of low gamma radiation levels are required. They read absorbed dose rate (or ambient dose equivalent rate) directly, eliminating the need for conversion from mR/h (or μGy/h). Question: What is meant by tissue-equivalent survey meter? Answer: The tissue-equivalent scintillator used in these instruments provides flat energy response calibrated in rem (or ambient dose equivalent H*(10)). This rem/H*(10) response is based on the deep dose equivalent index for 1 cm depth, unparallel directional beam as calculated on the ICRU standard sphere. Question: What is the measurement range of the instrument? Answer: The instrument gives tissue-equivalent photon response for x-ray and gamma radiation from environmental levels of 0-20 µrem/h (0-0.2 µSv/h) full scale up to normal survey levels of 200 mrem/h (2 mSv/h) full scale. Question: What options are available? Answer: Both the Micro Rem and the Micro Sievert Meters are available with a Standard or an Extended Probe and with Standard or Low Energy capabilities. A probe on the front of the lower case distinguishes the extended Probe option. The Low Energy option is distinguished by a window opening on the front of the lower case or on the front of the probe. The expanded low energy response option extends the instruments low energy cutoff to 17 keV verses 40 keV for the standard instrument. Question: What additional controls are available to the user. Answer: A switch-selectable Audio function provides audible pulses and full-scale alarm. A three- position response time switch provides adjustable meter response on all dose ranges. Question: What is the sensitivity of the detector? Answer: The sensitivity is 1.7 cps/µR/h (170 cps/µSv/h) or 100 cpm/µR/h.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    1 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us