20.5 Ion Detectors

20.5 Ion Detectors

20.5 Ion Detectors • the Faraday cup neutralizes ions to provide a high-precision measurement • the electron multiplier generates a pulse of current for each ion • the photon multiplier uses conversion dynodes to monitor both positive and negative ions • the two multipliers are capable of fast measurements, thus compatible with TOF or Fourier transform methods 20.5 : 1/4 Faraday Cup slit Ions exiting the analyzer are slowed by Faraday cup a positive potential and impact the ion + grounded electrode. At the electrode beam + they are __________ by electrons that RL travel through the load resistor. This ion suppressor causes a voltage across the load resistor that is measured by a high input impedance voltmeter. The impacted electrode is at an angle so that any secondary ions that are created are _____________ by the grounded wall. Of all ion detectors, the Faraday cup provides the most precise relationship between the number of ions exiting the analyzer and the electrical measurement. It is used in __________ experiments such as isotope dilution. Because very small currents are measured, the Faraday cup cannot be used for experiments involving rapid scanning. 20.5 : 2/4 Electron Multiplier ion beam An electron multiplier is constructed just like a photomultiplier but without 16e- 4e- 3 - a _______________. It has dynodes 10 e RL constructed from a Cu/Be alloy, which dynodes is a good secondary electron emitter. +V The dynode potentials are such that the first is grounded and each subsequent one is 100 V more positive. This makes the voltage measurement a little tricky because one end of the load resistor is connected to positive _____________. On average each dynode multiplies the current by ×4. A typical electron multiplier will have 10 to 15 dynodes for electron gains of 106 to 108. When used with magnetic analyzers the ions have sufficient kinetic energy to eject the first electron. With other analyzers the ion has to be accelerated into the first dynode. Since the output pulse has a statistical variation it is not as ______ as the Faraday cup. However, electron multipliers are very fast, making them compatible with TOF analyzers. 20.5 : 3/4 Photon Multipliers The detector has two _________ dynodes, a phosphorescent screen, and an ordinary photomultiplier. The dynodes convert either __________________ ions into electrons. The electrons are accelerated into the screen which emits light. The light is detected with a current to voltage converter. The advantages of the device are the ability to handle both positive and negative ions, a __________, and long lifetime. It is not as precise as a Faraday cup. 20.5 : 4/4.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    4 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us