New Controller Model Dedicated to Zenith Ventilation Units and Onyx Recuperators

New Controller Model Dedicated to Zenith Ventilation Units and Onyx Recuperators

New controller model dedicated to Zenith ventilation units and OnyX recuperators. This state-of-the-art control system integrates the func- tion of heat recovery system, heat/cold exchangers, ventilation equipment, measurement sensors, and other systems in a facility to provide for remote control via mobile devices. Basic properties of the controller Complete view of recuperator operating ecoNET Option of remote access from any parameters on a color touchscreen – place via a computer, tablet or visualization of the entire ventilation smartphone – ecoNET module. system operation. Software update via SD card. Air quality monitoring – temperature, humidity, gas concentration. Integration with BMS system owing GWC Cooperation with ground-coupled to Modbus RTU communication heat exchanger (GWC). protocol. Cooperation with duct-mounted Complex regulation of heat recovery heating and cooling coils. % degree. Other functions • Support of additional mixing chamber, • Automatic notifications about recommended technical • Automatic defrosting of heat exchanger, functions of checks, cyclical exchanger cleaning and definition of its • Multi-level, intuitive menu structure in Polish operating mode, and English. • Automatic free-cooling, • Cooperation with kitchen hoods, alarm systems, extinguishing systems, and other systems in the building, • Predefined operating modes, incl. venting, open windows, event, or different pressure levels in rooms (regulation of air supply and exhaust fan rotary speed against one another), • Possibility of creating customized unit operating modes, • Operating modes dedicated to cooperation with fireplaces and kitchen hoods, • Complex support of weekly operating schedule, • Read and archiving of alarms, is fully • Smooth control of air output from ventilation system within the range: 25-100%, compatible with other • Control of predefined temperature, Frapol automation systems, • Calculation of the volume of energy recovered by the including recuperator, FRAPOL Ltd PL 30-832 Kraków, ul. Mierzeja Wiślana 8 phone [+48] 12 653 27 66, [+48] 12 659 05 77 fax [+48] 12 653 27 89 [email protected] WWW.FRAPOL.COM.PL.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    2 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us