ABSTRACT REVIEW of PEP EXPERIMENTS Gerson Goldhaber

ABSTRACT REVIEW of PEP EXPERIMENTS Gerson Goldhaber

137 REVIEW OF PEP EXPERIMENTS Gerson Gol dhaber* Department of Physics, and Lawrence Berkeley Laboratory , University of California, Berkeley, California USA ABSTRACT Recent physics results from four PEP experiments : Mark II, MAC, DELCO, and TPC are presented herewith. The topics discussed deal with flavor tagging of charmed and bottom quarks, , and D0 lifetimes, Electroweak interference effects , searches for new particles and dE/dx measurements. *Work supported in part by the U.S. Department of Energy under contract DE-AC03- 76SF00098. 138 I wi ll present the fol lowing data from PEP in my tal k: l. A brief descri ption of the 4 PEP detectors from which data is presented here. 2. Results on fl avor tagging: Charm tagging via D*+ identification . Results from Mark II and DELCO . Charm and bottom quark tagging via semi leptonic decays . Results from Mark II and MAC. 3. T and D0 lifetime measurements with a Vertex Detector (Mark II). 4. Electroweak interference effects . Results from Mark II and MAC. 5. Search for new and pecul iar particles and speci fic decay modes ; Search for a µ* (MAC). + - Search for e e -+ '¥ + xand e+e- -+ T + x (Mark II). 6. Particle identifi cation in the TPC . l. The PEP Detectors I present herewi th summaries of 4 PEP Detectors as compiled by G. Gidal et al fo r the Particle Data Group at LBL. .1J A. Luminosity at PEP There has been a consideral:ile improvement in Luminosity at PEP. In particular peak Luminosity of 3.3 x 1031 cm- 2 sec-1 have been reached. Average running days have produced over 1000 nb-1. 139 MARK II LOCATION PEP e+e- storage ring SLAC, Stanford, CA, USA MAGNET 4. 6 kG coil solenoid, 1.5 m radius (currently running at 2. 3 kG) Al TRACKING Central drift chamber: Active length = 2.64 m, inner radius = 0.41 m, outer radius = 1.45 m 6 axial layers, stereo layers ( ±3°) JO 50% ethane, 50% argon = 200 u µ Vertex drift chamber: Cylindrical drift chamber, 1.2 m long, inner radius = 10 cm, outer radius = 35 cm Only axial wire layers ( 4 near r � 12 cm, 3 near r � 30 cm) u = 100 µ Be beam pipe (0.006)(,,) Combined (D.p/p)2 � (0.015)2 (0.0lp)2 + Tracks extrapolated to interaction pointwithin 100 µ. SHOWER COUNTERS 8 modules of Pb-liquid argon ( 15)(,, each), arranged in octagon outside coil Covers 64% of 4" 2 Pb sheets separated by 3 mm liquid argon gaps mm 37 layers (0.4X,, sampling) are ganged to provide 6 samples in depth Readout in 3. 8 cm wide strips in u directions D.E/E = 13%/ VE ¢, 8, TIME OF FLIGHT 48 scintillation counters read out at both ends Cover 753 of 4" 1.50 m flight path at � 90°; � 340 ps u separation up to 81.3 5 GeV /c at level K," Ju END CAPS 2 layers Pb-proportional chamber (5X,,) with 4 successive cathode strip readouts R-spiral, L-spiral) 503(8, argon, </>, 503 ethane MUON DETECTION Proportional tubes interleaved with steel absorber ( 4 layers each for total thickness of m) I covering 553 of 41f SMALL ANGLE TAGGING 6 planar drift chambers followed by shower counters LUMINOSITY Octagonal shower counters cover 22 mrad 80 mrad contain MONITOR 18 layers 1/4" Pb and 1/2" scintillator, read< 8 out < with BBQ wave shifter, front 5 layers separately from back 13 D.E/E � 15. 53/ 3 sets of scintillationVE counters REFERENCES G.S. Abrams et al., Phys Rev. Lett. (1979) 477, and 481. I. 43 ibid 2. W. Davies White et al., Nucl. Instr. Meth. ( 1979) 227. & 160 3. G.S. Abrams et al., IEEE Trans. Nucl. Sci. NS ( 1978) 309, and NS ( 1980) 59. 25 I, ibid 27 4. J.A. Jaros, Proc. Int. Conf. on Instrumentation for Colliding Beam Physics, SLAC-250 (1982). 140 MARK II ,-------- Vacuum Chamber Ve rtex Detector Drift Chamber me of Flight CountersTi Solenoid Coi I Liquid Argon -;--__/ Shower Counter Im Shower Counters Co1I ��S: End Cop T1me-of-Fl1ght Sc1nt1llo11on Counters '-- 4 -, 1 A Fi g. l 141 MAC (MAgnetic Calorimeter) LOCATION PEP e+e- storage ring SLAC, Stanford, CA, USA MAGNETS 5.7 kG solenoid, 7.5 cm thick coil Diameter = l m, length = 2.3Al m 17 kG iron toroids, m thick l TRACKING Cylindrical drift chamber 2. 2 m long, 12-45 cm tracking radius Argon - 10% methane at I atm. 10 layers, double sense wires �5 points on tracks over As:J 95% of 4,,. = 3° stereo gives Az 4 mm = dE/dx to 15% ± up/P 6.5% p = MUON DETECTION Muon tracking chambers 4 planes of I 0 cm diameter drift tubes surrounding magnetized iron toroids up/P = 30% = 97% of 4,,. An SHOWER DETECTORS Barrel: 14 of Pb - proportional chamber sandwich u /XoE 20%/ vE E = z-coordinate from charge division = 0.80, 1.30 "• <18 = Endcaps: 14 of Fe - proportional chamber sandwich u /XoE 45%/ E = <1>-coordinate fromvE cathode strips 1.50 "• = 20. "8 = Total: As:J 97% of 4,,. = HADRON CALORIMETER 5. 5 of Fe - proportional chamber sandwich u /EAabs 75%/VE E = u8 2°; u0 I (barrel), 4° (endcaps) = = As:J = 97% of 4,,.0 TIME OF FLIGHT 144 scintillation counters (72 barrel, 72 endcaps) r = 1.3 m At = Ins = 97% of 4,,. An LUMINOSITY MONITOR 4 scintillator /shower counter telescopes at 32 mrad horizontally REFERENCES I. R.L. Anderson et al., IEEE Trans. NS (1978) 340. 2. W.T. Ford, SLAC- PUB-2894, March 198225, (Proceedings SLAC International Conference on Instrumentation for Colliding Beams). 142 MAC (MAgnetic Calorimeter) MAC Detector Components : CD - Central Drift Chamber EC - End-cap Shower and SC - Shower Chamber (Central) Hadron Cal orimeters TC - Trigger/TOF Scintillators MO , Ml - Muon Drift Chambers HC - Hadron Calorimeter (Central ) Co ils - Sol enoid and Toroid XBL 831-7898 Fig. 2 143 DELCO LOCATION PEP e+e- ring SLAC, Stanford, CA, USA MAGNET Open-geometry (aperture I cosO < 0. 78) Pole-tip diameter 101 cm, separationI 125 cm B0 = 3.3 kG, fBdl = 1.8 kG- m TRACKING Central (cylindrical) drift chambers: 94 cm maximum wire length, 12-49 cm radius Low mass (2.3% Xo) Depth measurement by narrow angle stereo 16 points(z) on tracks with I cosO I < 0.69 Outer (planar) drift chambers: 285 cm wire length, 160 cm <radius> Depth measurement by wide angle stereo 6 points on tracks with I cosO I < 0.65 Multiple hit digital electronics ( 4 ns bin width) "p/P = v(2%-iJ2--+-T6o/;)2 = I CERENKOV COUNTER I atm. isobutane threshold counter 9. 1) 36 cells each with (pTP-coated) 5" ()',RCA 8854 quantacon Radiator length 55- 110 cm, <p.e. >=18, <N0>=80 cm-1 "• = 300 ps Acceptance I cosO < 0. 62 I SHOWER COUNTERS Barrel (IcosO < 0.62) : 48 Pb-scintillatorI counters, 6Xo Pole-tip (0.79 < lcosO I < 0.98) : 36 Pb-scintillator BBQ counters, 5Xo TIME OF FLIGHT 52 counters 324 cm length, 180 cm <radius> ' = " 350 ps Acceptance I cosO I < 0.67 LUMINOSITY MONITOR 12 Pb-scintillator BBQ counters, 16Xo Acceptance 25-68 mrad relative to beam axis REFERENCES I. W. Bacino et al., Phys. Rev. Lett. ( 1978) 67 1. 2. W.E. Slater et al., Nucl. Instr. Meth.40 (1978) 223. Ouimette et al., IEEE Trans.& NS No.154 I ( 1982) 290. 3. D. 29, 144 DELCO CYLI NDRICAL DRIFT CHAMBERS SHOWER COUNTERS TOF COUNTERS PHOTO TUBE � _r:: MAGNET5" COIL ==�� �=i������ii���� r= CYLINDRICAL INNER ­ DRIFT CHAMBERS POLE TIP SHOWER COUNTER MIRROR 10-82 438988 XBL 831-7897 Fig. 3 145 TPC 2 LOCATION PEP e+e- ring, Interaction Region (IR) SLAC, Stanford, CA. USA 1982-83: 4 kG coil solenoid ( 1.32X., coil package) MAGNET Al 1984: 14.5 kG superconducting coil (0. 86X., package) Diameter = 2. 15 m, length = 3.0 m TRACKING Time Projection Chamber (TPC) 2.0 m long (in z) at 20 to 100 cm radius (r) Argon-methane ( &Oo/c-20%) at 8. 5 atm. Max. drift l.O min 20 µSec, 75 kV /m drift electric field 183 proportional wire hits on tracks with !cos 0.71, each wire gives r,z and amplitude for six 60° sectors at each end and provides dE/dx meas. by multiple81 < ionization sampling 15 3-dim. space points from induced cathode signals on several of 13,824 channels to give r, ¢, and z (from the drift time), for I cos 0.71 ?.2 3-d points and ?.1581 <wire hits over 97% of 411"sterad Track pair resolution of 1-2 cm dE/dx ±3.5% for Bhabhas ±4.0% for tracks in jet events with 2:120 samples crp/p2 = ±3.6% for p2: 2 GeV/c position resolution in bending plane is 190 microns and in axial (z) direction 340 microns; presently low magnet field and drift distortions increase cr /p2 p Inner drift chamber at 13 to 19 cm radius 8.5 atm Ar-CH4 (80%--20%) , 150 microns in bend plane 1.2 m long covering 95% of 411", with 4 axial layers Outer drift chamber at 1.19 to 1.24 m radius atm Ar-CH4 (80o/o--20%), 200 microns in bend plane I 3 m long covering 77% of 411", with 3 axial layers POLE-TIP Gas, proJXlrtional mode, sampling Pb-laminate calorimeter CALORIMETER 2 modules, 13. 5Xo deep, at z m, covering 18% of 411" = I.I Argon-methane ( 80o/o--203) at 8. 5 atm; total of 51 samples Three 60° stereo views, each with 13 and 4 samples in depth Projective strip geometry with 8 mrad angular segment •E/E � ± 11%/YE, below JO GeV ±6.0% for Bhabhas at 14.5 GeV HEXAGONAL Gas, limited Geiger mode, sampling Pb-laminate calorimeter CALORIMETER 6 modules, lOXo deep, 4.2 m long at 1.2 m radius Argon-ethyl bromide (96%-4%) at atm.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    40 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us