These instructions are updated on a regular basis. Please visit our web site at http://www.swiftnets.com Copyright Swiftech 2004 – All rights reserved – Last revision date: 11-23-04 Rouchon Industries, Inc., dba Swiftech – 1703 E. 28th Street, Signal Hill, CA 90755 – Tel. 562-595-8009 – Fax 562-595-8769 - E Mail: [email protected] – URL: http://www.swiftnets.com - Information subject to change without notice Page 1 of 38 Packing List Included components per applicable model: H20-120-FB □ H20-120-SB □ H20-120-DB □ H20-120-BB □ H20-120-FK □ H20-120-SK □ H20-120-DK □ H20-120-BK □ Description Product Description Product Code Code Intel Pentium 4 socket 478 & AMD Athlon 64 F Intel Pentium 4 socket S & Opteron LGA775 & AMD Duron, Athlon, MP, XP socket 462 Dual Intel Xeon (all versions) / AMD Opteron D Base kit without water-block B ROYAL BLUE ‘’B’’ BLACK ‘’K’’ Product Qty Item Product Qty Item Code Code F 1 MCW6000 “Flat base” CPU D 2 Retention hardware for Xeon water-block with 2’each pre- “Nocona (800Mhz FSB) processors D 2 installed inlet/outlet tubing Models: MCW6000-P, MCW600- 64, MCW6000-PX and NX S 1 MCW6000 “Step base” CPU F,S,B 1 MCR120-F radiator assy. incl. (1) water-block with 2’each pre- Radiator, (1) 120x120x25mm fan, installed inlet/outlet tubing (4) M3.5 x 30mm philips screws, (4) M3.5 X 6mm philips screws Models: MCW6000-A, MCW6000- (2) hose clamps 775 S 1 Hold-down plate and retention F,S,D,B 1 Each, 12v to 7v adapter, and 12v to clips for AMD K7 processors 5v adapter (Duron, Athlon MP and XP) F 1 Hold-down plate and retention F,S,D,B 1 MCRES-1000 incl. (1) 5 ¼” Tray, hardware for AMD K8 (1) reservoir, MCP350 12 Volts D 2 processors (Athlon 64 and DC industrial pump with retention Opteron) screws, (1) fill-cap with o-ring, (4) Philips screws, (2) hose clamps F 1 Hold Down plate and retention F,S,D,B 1 40” length Coolsleeves clear coils clips for Intel Pentium 4 processors socket 478 (also use this retention plate with All Xeon processors, and some MSI D 2 Opteron motherboards) S 1 Hold Down plate and retention F,S,D,B 1 4 Feet ½” OD high quality vinyl hardware for Intel Pentium 4 tubing LGA775 processors D 2 Retention hardware for Xeon F,S,D,B 1 2 oz bottle HydrX specially socket 603/604 (400 & 533Mhz formulated coolant FSB) processors D 1 MCR120-FR complete radiator, fan and "Radbox" assembly, with (1) 120x25mm fans rated at 72.4CFM and 34dBA, PCI pass-thru kit, 3 pin to 4 pin Molex adapter Copyright Swiftech 2004 – All rights reserved – Last revision date: 11-23-04 Rouchon Industries, Inc., dba Swiftech – 1703 E. 28th Street, Signal Hill, CA 90755 – Tel. 562-595-8009 – Fax 562-595-8769 - E Mail: [email protected] – URL: http://www.swiftnets.com - Information subject to change without notice Page 2 of 38 TABLE OF CONTENTS I. TUBE ROUTING ..........................................................................................................................................................................................................6 II. INSTALLATION OF THE COOLING COMPONENTS ................................................................................................................................................7 1. MCR120-F Radiator installation..............................................................................................................................................................................7 2. Water-block(s) Installation ......................................................................................................................................................................................8 3. Preparing the tubing................................................................................................................................................................................................9 4. MCRES-1000P assembly installation ...................................................................................................................................................................10 A) First time installation and preferred filling procedure ............................................................................................................................................10 B) Alternate filling procedure .....................................................................................................................................................................................12 5. Notes and Troubleshooting...................................................................................................................................................................................13 6. MCP350 Pump Specifications............................................................................................................................................................................13 7. Completing the installation....................................................................................................................................................................................14 III. DRAINING THE SYSTEM..........................................................................................................................................................................................14 IV. PERIODIC MAINTENANCE ......................................................................................................................................................................................14 V. AVAILABLE ACCESSORIES....................................................................................................................................................................................15 VI. APPENDIX: INDIVIDUAL COMPONENT INSTALLATION GUIDES.......................................................................................................................16 MCB-120™ “RADBOX” KIT INSTALLATION GUIDE ........................................................................................................................................................17 1. PCI pass-thru kit installation .................................................................................................................................................................................17 2. Housing / fan & radiator installation ......................................................................................................................................................................18 MCW6000-P™ WATER-BLOCK FOR INTEL PENTIUM 4 (SOCKET 478) ........................................................................................................................19 1. Preparing your Motherboard .................................................................................................................................................................................19 2. Water-block orientation .........................................................................................................................................................................................19 3. Water-block installation:........................................................................................................................................................................................20 4. Connecting the water-block(s) to the cooling circuit: ............................................................................................................................................20 5. Attaching the tubes: ..............................................................................................................................................................................................20 6. Type of Coolant:....................................................................................................................................................................................................20 7. Final inspection: ....................................................................................................................................................................................................20 MCW6000-775 WATER-BLOCK FOR INTEL PENTIUM 4 (LGA 775) INSTALLATION GUIDE ..................................................................................21 1. Preparing your Motherboard .................................................................................................................................................................................22 2. Retention Posts installation...................................................................................................................................................................................22 3. Purging the water-block ........................................................................................................................................................................................22 4. Connecting the water-block(s) to the cooling circuit .............................................................................................................................................22 5. Applying thermal compound to the CPU...............................................................................................................................................................22 6. Fasten the water-block to motherboard ................................................................................................................................................................22 MCW6000-PX™
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages38 Page
-
File Size-