Safety Data Sheet

Safety Data Sheet

SAFETY DATA SHEET Creation Date 13-Oct-2009 Revision Date 19-Mar-2018 Revision Number 1 SECTION 1: IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING 1.1. Product identification Product Description: Magnesium iodide Cat No. : 14283 CAS-No 10377-58-9 Molecular Formula I2 Mg Reach Registration Number - 1.2. Relevant identified uses of the substance or mixture and uses advised against Recommended Use Laboratory chemicals. Uses advised against No Information available 1.3. Details of the supplier of the safety data sheet Company Alfa Aesar . Avocado Research Chemicals, Ltd. Shore Road Port of Heysham Industrial Park Heysham, Lancashire LA3 2XY United Kingdom Office Tel: +44 (0) 1524 850506 Office Fax: +44 (0) 1524 850608 E-mail address [email protected] www.alfa.com Product Safety Department 1.4. Emergency telephone number Call Carechem 24 at +44 (0) 1865 407333 (English only); +44 (0) 1235 239670 (Multi-language) SECTION 2: HAZARDS IDENTIFICATION 2.1. Classification of the substance or mixture CLP Classification - Regulation (EC) No 1272/2008 Physical hazards Based on available data, the classification criteria are not met Health hazards Based on available data, the classification criteria are not met Environmental hazards ______________________________________________________________________________________________ ALFAA14283 Page 1 / 9 SAFETY DATA SHEET Magnesium iodide Revision Date 19-Mar-2018 ______________________________________________________________________________________________ Based on available data, the classification criteria are not met 2.2. Label elements Hazard Statements Precautionary Statements 2.3. Other hazards No information available SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS 3.1. Substances Component CAS-No EC-No. Weight % CLP Classification - Regulation (EC) No 1272/2008 Magnesium iodide (MgI2) 10377-58-9 EEC No. 233-825-1 >95 - Reach Registration Number - Full text of Hazard Statements: see section 16 SECTION 4: FIRST AID MEASURES 4.1. Description of first aid measures Eye Contact Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention. Skin Contact Wash off immediately with plenty of water for at least 15 minutes. Get medical attention immediately if symptoms occur. Ingestion Clean mouth with water and drink afterwards plenty of water. Get medical attention if symptoms occur. Inhalation Move to fresh air. Get medical attention immediately if symptoms occur. Self-Protection of the First Aider No special precautions required. 4.2. Most important symptoms and effects, both acute and delayed None reasonably foreseeable. 4.3. Indication of any immediate medical attention and special treatment needed Notes to Physician Treat symptomatically. ______________________________________________________________________________________________ ALFAA14283 Page 2 / 9 SAFETY DATA SHEET Magnesium iodide Revision Date 19-Mar-2018 ______________________________________________________________________________________________ SECTION 5: FIREFIGHTING MEASURES 5.1. Extinguishing media Suitable Extinguishing Media Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide. Extinguishing media which must not be used for safety reasons No information available. 5.2. Special hazards arising from the substance or mixture Thermal decomposition can lead to release of irritating gases and vapors. Hazardous Combustion Products Hydrogen iodide. 5.3. Advice for firefighters As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear. SECTION 6: ACCIDENTAL RELEASE MEASURES 6.1. Personal precautions, protective equipment and emergency procedures Ensure adequate ventilation. Use personal protective equipment. Avoid dust formation. 6.2. Environmental precautions Should not be released into the environment. See Section 12 for additional ecological information. 6.3. Methods and material for containment and cleaning up Sweep up or vacuum up spillage and collect in suitable container for disposal. Avoid dust formation. 6.4. Reference to other sections Refer to protective measures listed in Sections 8 and 13. SECTION 7: HANDLING AND STORAGE 7.1. Precautions for safe handling Wear personal protective equipment. Ensure adequate ventilation. Avoid contact with skin, eyes and clothing. Avoid ingestion and inhalation. Avoid dust formation. Hygiene Measures Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing before re-use. Wash hands before breaks and at the end of workday. 7.2. Conditions for safe storage, including any incompatibilities ______________________________________________________________________________________________ ALFAA14283 Page 3 / 9 SAFETY DATA SHEET Magnesium iodide Revision Date 19-Mar-2018 ______________________________________________________________________________________________ Keep containers tightly closed in a dry, cool and well-ventilated place. Keep under nitrogen. Store under an inert atmosphere. Protect from moisture. 7.3. Specific end use(s) Use in laboratories SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION 8.1. Control parameters Exposure limits This product, as supplied, does not contain any hazardous materials with occupational exposure limits established by the region specific regulatory bodies Biological limit values This product, as supplied, does not contain any hazardous materials with biological limits established by the region specific regulatory bodies Monitoring methods BS EN 14042:2003 Title Identifier: Workplace atmospheres. Guide for the application and use of procedures for the assessment of exposure to chemical and biological agents. MDHS14/3 General methods for sampling and gravimetric analysis of respirable and inhalable dust Derived No Effect Level (DNEL) No information available Route of exposure Acute effects (local) Acute effects Chronic effects Chronic effects (systemic) (local) (systemic) Oral Dermal Inhalation Predicted No Effect Concentration No information available. (PNEC) 8.2. Exposure controls Engineering Measures None under normal use conditions. Personal protective equipment Eye Protection Safety glasses with side-shields (European standard - EN 166) Hand Protection Protective gloves Glove material Breakthrough time Glove thickness EU standard Glove comments Natural rubber See manufacturers - EN 374 (minimum requirement) Nitrile rubber recommendations Neoprene PVC Skin and body protection Wear appropriate protective gloves and clothing to prevent skin exposure Inspect gloves before use. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. ______________________________________________________________________________________________ ALFAA14283 Page 4 / 9 SAFETY DATA SHEET Magnesium iodide Revision Date 19-Mar-2018 ______________________________________________________________________________________________ (Refer to manufacturer/supplier for information) Ensure gloves are suitable for the task: Chemical compatability, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Remove gloves with care avoiding skin contamination. Respiratory Protection No protective equipment is needed under normal use conditions. Large scale/emergency use Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced Recommended Filter type: Particle filter Small scale/Laboratory use Maintain adequate ventilation Environmental exposure controls No information available. SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES 9.1. Information on basic physical and chemical properties Appearance White Physical State Powder Solid Odor No information available Odor Threshold No data available pH No information available Melting Point/Range 637 °C / 1178.6 °F Softening Point No data available Boiling Point/Range No information available Flash Point No information available Method - No information available Evaporation Rate Not applicable Solid Flammability (solid,gas) No information available Explosion Limits No data available Vapor Pressure No data available Vapor Density Not applicable Solid Specific Gravity / Density No data available Bulk Density No data available Water Solubility 1480 g/L Solubility in other solvents No information available Partition Coefficient (n-octanol/water) Autoignition Temperature Not applicable Decomposition Temperature No data available Viscosity Not applicable Solid Explosive Properties No information available Oxidizing Properties No information available 9.2. Other information Molecular Formula I2 Mg Molecular Weight 278.11 SECTION 10: STABILITY AND REACTIVITY 10.1. Reactivity None known, based on information available ______________________________________________________________________________________________ ALFAA14283 Page 5 / 9 SAFETY DATA SHEET Magnesium iodide Revision Date 19-Mar-2018 ______________________________________________________________________________________________ 10.2. Chemical stability Hygroscopic, Light sensitive,

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    9 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us