Structural Application Chart

Structural Application Chart

Structural Applications of Taylor Fluid Viscous Dampers SUMMARY Total Number of Structures = 612 Buildings = 446 Bridges = 145 Other = 21 Total Number of Dampers = 23,286 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information New Gerald Desmond Bridge USA, Long Beach, CA Taylor Fluid Dampers 2016 Seismic New cable stayed bridge with a main span of 120m and a total Total: 34 length of 1565m uses fused dampers between the towers and 3930 kN ± 813mm stroke bridge deck to limit motion and dissipate seismic energy. 3930 kN ± 1016mm stroke 3470 kN ± 508mm stroke Deryunn JingDing Project Taiwan, Taipei Taylor Fluid Dampers 2015 Seismic A residential project using viscous dampers to dissipate Total: 56 seismic energy. 500 kN ± 55mm stroke Xinchuang Project Taiwan, Taipei Taylor Fluid Dampers 2015 Seismic A residential project using viscous dampers to dissipate Total: 52 seismic energy. 500 kN ± 55mm stroke Arch of Triumph Romania, Bucharest Taylor Fluid Dampers 2015 Seismic Long stroke dampers are incorporated in this base isolation Total: 8 project for drift control. 1500 kN ± 500mm stroke Cow Bayou Bridge USA, Texas Taylor Fluid Dampers 2015 Impact Swing bridge application. Buffer used to cushion impact loads Total: 1 upon closing of bridge. 155 kN 100mm stroke Ever Living Construction Taiwan, Taipei Taylor Fluid Dampers 2015 Seismic A residential project using viscous dampers to dissipate Total: 40 seismic energy. 500 kN ± 75mm stroke Page 1 of 50 2015 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information 4 Residential Buildings Indonesia, Jakarta Taylor Fluid Dampers 2015 Seismic Four high rise residential towers utilize dampers to dissipate Total: 289 seismic energy and reduce drift. 4000 kN ± 100mm stroke Today's Fresh Start Charter School USA, Inglewood, CA Taylor Viscous Dampers 2015 Seismic New school athletic complex uses dampers in chevron braces Total: 8 to dissipate seismic energy. 160 kN ± 75mm stroke Washington Hospital USA, Fremont, CA Taylor Viscous Dampers 2015 Seismic New base isolated hospital utilizes dampers at the level of the Total: 32 isolators to reduce displacment and provide energy 2225 kN ± 915mm stroke dissipation. Yuanfu Sanchong Project Taiwan, Taipei Taylor Viscous Dampers 2015 Seismic New residential building uses dampers to reduce deflection Total: 63 and provide energy dissipation. 500 kN ± 55mm stroke Horngiuu Beitou Project Taiwan, Taipei Taylor Viscous Dampers 2015 Seismic New residential building uses dampers to reduce deflection Total: 16 and provide energy dissipation. 500 kN ± 75mm stroke Shengxing Jinghua Project Taiwan, Taipei Taylor Viscous Dampers 2015 Seismic New residential building uses dampers to reduce deflection Total: 6 and provide energy dissipation. 500 kN ± 75mm stroke Test Stand for a Space Exploration USA Taylor Viscous Dampers 2015 Vibration Dampers used to reduce vibrations in piping for a test facility. Company Total: 9 735 kN ± 25mm stroke 555 Capitol Mall USA, Sacramento, CA Taylor Viscous Dampers 2015 Seismic Seismic upgrade of two 14 storey office buildings. Dampers Total: 16 used to reduce displacment and provide energy dissipation. 1500 kN ± 125mm stroke Page 2 of 50 2015 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information High Tech Facility USA, Santa Clara, CA Taylor Viscous Dampers 2015 Seismic Voluntary seismic upgrade of a high tech facility. Total: 12 1500 kN ± 125mm stroke Nagasaki Government Building Japan, Nagasaki Taylor Viscous Dampers 2015 Seismic Dampers used to provide energy dissipation and reduce Total: 7 displacement due to earthquake motion. 1200 kN ± 50mm stroke Loma Linda University Medical Center USA, Loma Linda, CA Taylor Viscous Dampers 2015 Seismic New base isolated hospital utilizes dampers at the level of the Total: 82 isolators to reduce displacment and provide energy 3000 kN ± 1067mm stroke dissipation. TSMC FAB #15, P5 Taiwan, Tainan Taylor Viscous Dampers 2015 Seismic Retrofit of a semiconductor fabrication plant uses dampers to Total: 52 dissipate seismic energy and reduce vibrations in earthquake. 2000 kN ± 75mm stroke Phone Company Data Center Turkey Taylor Viscous Dampers 2015 Seismic Base isolated structure uses dampers at the level of the Total: 12 isolators to reduce displacement. 1700 kN ± 610mm stroke Yinchuan Yellow River Bridge China Taylor Viscous Dampers 2015 Seismic New bridge uses dampers to control longitudinal movement. Total: 6 5016 kN ± 396mm stroke 2374 kN ± 300mm stroke 432 Park Avenue USA, New York, NY Taylor Viscous Dampers 2015 Wind New 89-story, 426m tall reinforced concrete structure uses Total: 16 dampers as part of a Tuned Mass Damper to improve 133 kN ± 1016mm stroke occupant comfort during wind storms. Naval Medical Center San Diego USA, San Diego, CA Taylor Viscous Dampers 2015-2016 Seismic Retrofit of steel moment frame structure uses dampers in Total: 163 diagonal bracing elements to dissipate seismic energy. 900 kN ± 225mm stroke 29 Palms Naval Hospital USA, 29 Palms, CA Taylor Viscous Dampers 2015 Seismic Retrofit of steel moment frame structure uses dampers in Total: 53 diagonal bracing elements to dissipate seismic energy. 900 kN ± 225mm stroke Page 3 of 50 2015 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information 181 Fremont Street USA, San Francisco, CA Taylor Viscous Dampers 2015 Seismic & Wind Custom long life metal bellows dampers used with megabraces Total: 32 to control seismic and wind vibrations in a new 54-story, 244m 2000 kN ± 150mm stroke tall mixed use building Shiji Railway Bridge China, Shandong Taylor Lock-Up Devices 2015 Seismic New bi-purpose continuous steel truss bridge with 180m main Total: 12 span uses LUDs between the bridge truss and piers to 4000 kN ± 150mm stroke distribute seismic/braking loads. Boeing Building 3-390 USA Taylor Viscous Dampers 2015 Seismic Flight test hangar uses external diagonal struts with dampers Total: 2 to absorb seismic energy. 3115 kN ± 325mm stroke Farglory H99 Taiwan, Xinbei City Taylor Viscous Dampers 2015 Seismic A residential project consisting of two 23-story SRC buildings, Total: 72 using viscous dampers to dissipate seismic energy. 1000 kN ± 75mm stroke Academia Sinica Taiwan, Taipei Taylor Viscous Dampers 2015 Seismic New 6-story research center project, dampers are installed in Total: 10 a base isolation system to reduce earthquake movement. 1600 kN ± 610mm stroke CEC B7-Xinyi Building Taiwan, Taipei City Taylor Viscous Dampers 2015 Seismic A residential project consists of two 31-story steel structures, Total: 208 using viscous dampers to reduce wind-induced vibrations. 500 kN ± 55mm stroke 12 Moorhouse Avenue New Zealand, Christchurch Taylor Viscous Dampers 2015 Seismic Office building application, part of the rebuild from the Total: 55 Christchurch Earthquakes 250 kN ± 75mm stroke 500 kN ± 100mm stroke 750 kN ± 100mm stroke 1000 kN ± 100mm stroke SFKH Banqiao Financial Center Taiwan, Xinbei City Taylor Viscous Dampers 2015 Seismic Fluid viscous dampers are used in this steel structure to Total: 22 reduce vibration under earthquakes. 1000 kN ± 100mm stroke Sunpo Zhubei Taiwan, Hsinchu City Taylor Viscous Dampers 2015 Seismic Fluid viscous dampers are used to reduce vibration under Total: 8 earthquakes. 500 kN ± 75mm stroke Taoyuan Building Taiwan, Taoyuan Taylor Viscous Dampers 2015 Seismic New 26-story RC residential building uses dampers to Total: 36 dissipate seismic energy. 500 kN ± 75mm stroke Page 4 of 50 2015 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Weihua Taoyuan Building Taiwan, Taoyuan City Taylor Viscous Dampers 2015 Seismic A residential project using fluid viscous dampers to reduce Total: 41 seismic vibrations. 500 kN ± 75mm stroke Insurance Company Office Building USA, Los Angeles, CA Taylor Viscous Dampers 2015 Seismic Retrofit of an office building uses dampers to enhance seismic Total: 22 performance. 2700 kN ± 125mm stroke Banco De La Nacion Building Peru, Lima Taylor Viscous Dampers 2015 Seismic New building uses dampers to enhance seismic performance. Total: 16 2600 kN ± 75mm stroke Futsang Dazhu Building Taiwan, Taoyuan City Taylor Viscous Dampers 2015 Seismic A residential project using fluid viscous dampers to reduce Total: 20 seismic vibrations. 500 kN ± 55mm stroke Pacifico Insurance Building Peru, Lima Taylor Viscous Dampers 2015 Seismic New building uses dampers to enhance seismic performance. Total: 48 650 kN ± 75mm stroke Nashua Street Residences USA, Boston, MA Taylor Viscous Dampers 2015 Seismic/Wind New 38 story residential building uses dampers in toggle Total: 30 braces to reduce acceleration and displacement during wind 150 kN ± 250mm stroke storms. Kioi Building Japan, Tokyo Taylor Viscous Dampers 2015 Seismic New 162m, 33-story steel frame building for hotel, offices and Total: 269 stores uses dampers to dissipate earthquake energy. 2000 kN ± 75mm stroke San Diego Central Courthouse USA, San Diego, CA Taylor Viscous Dampers 2015 Seismic New 22 story steel moment frame building uses dampers to Total: 106 reduce displacements in the weak direction. 2000 kN ± 125mm stroke 1500 kN ± 100mm stroke Tu-Cheng "Hi Oasis" Building Taiwan, Xinbei City Taylor Viscous Dampers 2015 Seismic Fluid viscous dampers are used in two residential buildings to Total: 72 reduce structural responses under earthquakes. 500 kN ± 75mm stroke Kentucky Lake Bridge USA, KY Taylor

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    50 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us