3Com Baseline Switch 2816, 2824 User Guide

3Com Baseline Switch 2816, 2824 User Guide

3Com® Baseline Switch 2824 (3CBLUG16) 3Com® Baseline Switch 2816 (3CBLUG24) User Guide Installationsanleitung 10017053 Rev AA Oct 2008 10/1 00 / 1000 Status Baseline Switch 2824 Link/Activity : G 3CBLUG24 reen = 1000M, Yellow = 10/100M, Flash = Activity INTRODUCTION The 3Com Baseline Switch 2824 and the 3Com Baseline Switch can operate in half or full duplex mode. At 1000 Mbps, the 2816 are versatile, easy-to-use switches. It is ideal for users who ports operate in full duplex mode only. want the high-speed performance of 10/100/1000 switching but do not need sophisticated management functions. The Switch is shipped ready for use. No configuration is necessary. Your 3Com Dual Speed Switch Baseline Switch incorporates the latest in Green technology to with 10/100 Mbps yield more than 25% power savings over the previous connection technology. The Switch can be rack-mounted or free standing. Your Switch includes: Switch 2824 One power cord Rack mounting kit Four standard height, self-adhesive rubber pads 1000Mbps Servers with connections This User Guide and warranty card 1000Mbps connections The Switch is powered from the AC mains supply. 10/100Mbps Switch with Gigabit Connection The Switch provides high performance switched connections to 10 Mbps, 100 Mbps, and 1000 Mbps hubs, switches, servers and workstations that need a dedicated switched link. The following figure illustrates one possible configuration. Each port has a shielded RJ-45 connector on the front panel. Each port is capable of operating at 10 Mbps, 100 Mbps or 1000 Mbps. The ports can automatically determine the speed and the duplex mode of the connected equipment and provides a suitable switched connection. At 10 Mbps and at 100 Mbps, the ports 1 FEATURES OF THE SWITCH 1 Baseline Switch 2824 3CBLUG24 1 4 5 8 9 12 10 / 100 / 1000 Status 13 16 17 20 21 24 Link/Activity : Green = 1000M, Yellow = 10/100M,Flash = Activity 4 2 3 The numbers in this diagram refer to numbered sections in the CAUTION: The Switch supports full duplex text. A 24-port unit is shown. auto-negotiation. If the connected device does not ! support auto-negotiation, the Switch will operate in half Front Panel duplex mode, and therefore can only operate at 1 24 RJ-45 10/100/1000 Ports 10 Mbps or 100 Mbps. In such a configuration, you may notice some degradation of network performance. WARNING: RJ-45 ports. These are shielded RJ-45 data 3Com recommends that you use devices that are sockets. They cannot be used as standard traditional capable of auto-negotiation (and that you ensure that telephone sockets, or to connect the unit to a traditional auto-negotiation is enabled, if it is a configurable PBX or public telephone network. Only connect RJ-45 option). data connectors, network telephony systems, or network telephones to these sockets. Either shielded or All ports auto-sense an MDI/MDIX connection so each port can unshielded data cables with shielded or unshielded jacks be connected to a device with a normal ‘straight through’ TP can be connected to these data sockets. (twisted pair) cable or a ‘cross-over’ TP cable. Any port can AVERTISSEMENT: Les ports RJ-45. Ceux-ci sont therefore be used to connect to either another switch port, protégés par des prises de données. Ils ne peuvent pas server, or workstation without additional configuration. être utilisés comme prises de téléphone conventionnelles standard, ni pour la connection de l’unité à un réseau Traffic Prioritization téléphonique central privé ou public. Raccorder seulement connecteurs de données RJ-45, systèmes de The Switch offers priority queuing, which means all packets that réseaux de téléphonie ou téléphones de réseaux à ces are received are examined to see if they have been priority prises. Il est possible de raccorder des câbles protégés ou encoded. When a packet is received, the Switch will read the non protégés avec des jacks protégés ou non protégés à priority level and determine the appropriate channel to forward ces prises de don. the packet based on the priority level. This feature can be useful, WARNUNG: RJ-45-Porte. Diese Porte sind geschützte for example, during excessive loads when one type of traffic may Datensteckdosen. Sie dürfen weder wie normale require priority over another. The Switch is configured to comply traditionelle Telefonsteckdosen noch für die Verbindung with 802.1p, VLAN tagged frames. der Einheit mit einem traditionellem privatem oder öffentlichem Telefonnetzwerk gebraucht werden. Nur Traffic prioritization ensures that high priority data is forwarded RJ-45-Datenanscluße, Telefonnetzsysteme or through the Switch without being delayed by lower priority data. Netztelefone an diese Steckdosen anschließen. Entweder It differentiates traffic into classes and prioritizes those classes geschützte oder ungeschützte Buchsen dürfen an diese automatically. Traffic prioritization uses the multiple traffic queues Datensteckdosen angeschlossen werden. that are present in the hardware of the Switch to ensure that high priority traffic is forwarded on a different queue from lower The Switch has 24/16 10/100/1000 Mbps auto-negotiating ports. priority traffic, and is given preference over that traffic. This Each port automatically negotiates with the attached device to ensures that time-sensitive traffic gets the highest level of service. determine the correct speed and duplex mode of operation. The 802.1D standard specifies eight distinct levels of priority Once negotiated, the port will operate in one of the following (0 to 7), each of which relates to a particular type of traffic. The modes: priority levels and their traffic types are shown in the following table. 10BASE-T half duplex 10BASE-T full duplex 100BASE-TX half duplex 100BASE-TX full duplex 1000BASE-T full duplex 2 Priority Level Traffic Type Flashing Packets are being received or transmitted on the port. 0 Best Effort Off The link has not been established, either nothing is connected to the port, or there is a problem: 1 Background ■ Check that the attached device is powered on. 2 Standard (spare) ■ Check that the cable is the correct type and is not faulty. If these checks do not identify the cause of the problem, it 3 Excellent Effort (business critical) may be that the unit or the device connected to the port is faulty. Contact your supplier for further advice. 4 Controlled Load (streaming multimedia) 5 Video (Interactive media), less than 100 milliseconds latency and jitter. 3 Power LED 6 Voice (Interactive voice), less than 10 milliseconds The Power LED shows the power status of the Switch: latency and jitter. 7 Network Control Reserved traffic Status Meaning The traffic prioritization feature supported by the Switch Green The unit is powered on and ready for use. is compatible with the relevant sections of the IEEE Off ■ The unit is not receiving power: 802.1D standard (incorporating IEEE 802.1p). ■ Check that the power cord is connected correctly. ■ If the unit still does not operate, contact your supplier. 2 Activity/Link/Speed Status LEDs The LED, labelled “Link/Activity,” shows the link and activity Rear Panel Connections status of the related ports: 4 Power Supply Status Meaning The Switch automatically adjusts to the supply voltage. Only use Green The link is operating at 1000 Mbps. the power cord that is supplied with the unit. Yellow The link is operating at 10 or 100 Mbps. INSTALLING THE SWITCH Positioning the Switch on top of the lower unit, ensuring that the pads locate with the recesses of the lower unit. When deciding where to position the Switch ensure: Do not apply the pads if you intend to rack mount the unit. It is accessible and cables can be connected easily. Cabling is away from sources of electrical noise. These CAUTION: If installing the Switch in a free standing include lift shafts, microwave ovens, and air conditioning stack of different sized units, the smaller units must be units. Electromagnetic fields can interfere with the signals on ! installed above the larger ones. Do not build a free copper cabling and introduce errors, therefore slowing down standing stack of more than six units. your network. Montagesatz Anweisungen Water or moisture cannot enter the case of the unit. Der Switch wird mit zwei Halterungen und vier Schrauben Air flow around the unit and through the vents in the side geliefert. Diese werde für den Einbau in einen Baugruppenträger of the case is not restricted (3Com recommends that you benutzt. Bei der Montage der Baugruppe beachten Sie die provide a minimum of 25 mm (1 in.) clearance). Anweisungen aus “Positioning the Switch”. The air is as free from dust as possible. ACHTUNG: Entfernen Sie alle Kabel, bevor Sie Temperature operating limits are not likely to be exceeded. It fortfahren. Entfernen Sie die selbstklebenden Polster is recommended that the unit is installed in a clean, air ! (Füße) von der Unterseite der Baugruppe, falls diese conditioned environment. bereits angebracht sind. It is always a good practice to wear an anti-static wrist 1 Plazieren Sie die Baugruppe aufrecht auf einer harten, strap when installing network equipment, connected to a ebenen Fläche mit der Vorderseite zu Ihnen. ground point. If one is not available, try to keep in contact with a grounded rack and avoid touching the 2 Ordnen Sie eine der Halterungen über den Löchern an der unit's ports and connectors, if possible. Static discharge Seite der Baugruppe an. can cause reliability problems in your equipment. 3 Stecken Sie zwei der mitgelieferten Schrauben in die Löcher und drehen Sie diese mit einem geeigneten Schraubendreher Rack Mounting or Free Standing fest. This unit can be mounted in a 19-inch equipment rack using the 4 Widerholen Sie letzten beiden Schritte auf der anderen Seite Mounting Kit. Refer to “Mounting Kit Instructions” on page 4.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    8 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us