Year in Review 2015: Neonatal Respiratory Care

Year in Review 2015: Neonatal Respiratory Care

RESPIRATORY CARE Paper in Press. Published on March 15, 2016 as DOI: 10.4187/respcare.04787 Year in Review 2015: Neonatal Respiratory Care Sherry E Courtney MD MSc Introduction American Heart Association Neonatal Resuscitation Guidelines Assessment of Heart Rate Delayed Cord Clamping Temperature Control Respiratory Management Discontinuing or Not Initiating Care Apgar Score Off-Label Use of Inhaled Nitric Oxide Surfactant Administration Hypo- and Hypercarbia Automated Control of Oxygen Saturation Summary Neonatal respiratory care practices have changed with breathtaking speed in the past few years. It is critical for the respiratory therapist and others caring for neonates to be up to date with current recommendations and evolving care practices. The purpose of this article is to review papers of particular note that were published in 2015 and address important aspects of newborn respiratory care. Key words: neonatal respiratory care, Apgar score, inhaled nitric oxide, surfactant, resuscitation, oxygen saturation [Respir Care 0;0(0):1–•. © 0 Daedalus Enterprises] Introduction when initial CPAP in the delivery room was rarely used, and when all mechanical ventilation for the neo- Many practitioners of neonatal care may remember, nate was pressure-controlled and not volume-targeted. not so very long ago, when all babies received 100% Neonatal respiratory care is changing rapidly, based on oxygen at birth, when all infants with meconium-stained new clinical trials and better understanding of physiol- fluid were intubated and suctioned, when all preterm ogy. This paper highlights important current changes infants were intubated at birth and given surfactant, and some developments on the horizon in respiratory care of the neonate. Dr Courtney is affiliated with the Department of Pediatrics, University of American Heart Association 2015 Consensus on Arkansas for Medical Sciences, Little Rock, Arkansas. Neonatal Resuscitation Dr Courtney has disclosed relationships with Salter Labs, Pfizer Labs, Radiometer, Discovery Labs, Draeger, Infant Bacterial Therapeutics, United Therapeutics, and Maquet. The following are major changes that will affect new- born resuscitation. The full text of these and other changes, Correspondence: Sherry E Courtney MD MSc, Arkansas Children’s Hos- as well as a summary of the evidence, is available through pital, Section of Neonatology, One Children’s Way Slot 512-5, Little Rock, AR 72202. E-mail: [email protected]. the American Heart Association (AHA) and published in Circulation,1,2 and has been reprinted in several other jour- DOI: 10.4187/respcare.04787 nals. RESPIRATORY CARE • ●●VOL ● NO ● 1 Copyright (C) 2016 Daedalus Enterprises ePub ahead of print papers have been peer-reviewed, accepted for publication, copy edited and proofread. However, this version may differ from the final published version in the online and print editions of RESPIRATORY CARE RESPIRATORY CARE Paper in Press. Published on March 15, 2016 as DOI: 10.4187/respcare.04787 YEAR IN REVIEW 2015: NEONATAL RESPIRATORY CARE Assessment of Heart Rate end-expiratory pressure may not be achieved even with a PEEP valve. A policy statement on the use of CPAP has Practitioners should be aware that palpation of the um- recently been issued by the American Academy of Pedi- bilical cord as well as auscultation are often inaccurate and atrics (AAP) Committee on Fetus and Newborn.5 underestimate the heart rate. The most accurate measure- Since the AAP and the AHA now recommend early use ment of heart rate appears to be by electrocardiography. of CPAP, it is my recommendation that all hospitals where This does not replace the need for pulse oximetry to assess deliveries may occur provide a mechanism for nasal CPAP oxygenation. administration. Delayed Cord Clamping Sustained Inflations. Sustained inflations have been ad- vocated to establish functional residual capacity in preterm Delayed cord clamping for Ͼ30 s is reasonable for in- infants. Several trials have evaluated the use of sustained fants, both term and preterm, who do not require imme- inflation, but length of inflations and peak inspiratory pres- diate resuscitation at birth. An alternative approach, rou- sures employed vary widely among studies. The AHA tine milking of the cord, is not recommended for infants does not recommend a sustained inflation of Ͼ5s,but Ͻ29 weeks gestation due to lack of evidence at this time. shorter sustained inflations may be considered in individ- Given that delayed cord clamping may provide benefits ual circumstances. Readers may wish to review the meta- for the newborn and is now suggested for preterm infants analysis of the randomized trials done to date.6 This meta- not requiring immediate resuscitation, delivery services analysis found that preterm infants treated with sustained should develop protocols for this intervention and should inflation required less mechanical ventilation but concluded utilize a multidisciplinary approach. that further study is needed. Temperature Control Laryngeal Mask. For infants of Ն34 weeks gestation, a laryngeal mask airway is an alternative to intubation. If Admission temperature of nonasphyxiated infants intubation is not feasible or is unsuccessful, use of a la- strongly predicts mortality, and hypothermia is still a prob- ryngeal mask airway can be lifesaving and is recommended lem in many cases. Preterm infants are at especially high by the AHA. In my opinion, any institution where deliv- risk of morbidity and mortality. The AHA strongly rec- eries may occur should have laryngeal masks in the de- ommends maintenance of infant temperature between 36.5 livery room, and their proper use should be regularly re- and 37.5°C. viewed. There are many ways to improve infant temperature control, including increased room temperature, plastic Intubation and Tracheal Suctioning in Nonvigorous In- wraps, caps, and thermal mattresses. For respiratory sup- fants Born Through Meconium. This is perhaps the port, however, one thing that can be done is the use of biggest change in the Neonatal Resuscitation Program warmed, humidified gas in the delivery room. The AHA (NRP) recommendations. For years, we have intubated mentions this in the current guidelines as an intervention and suctioned infants born with meconium-stained amni- that is effective in reducing hypothermia. Articles by otic fluid. In the past, all such babies were intubated; in te Pas et al3 and Meyer et al4 provide data to support this more recent times, only depressed, nonvigorous infants recommendation. were intubated and suctioned. Given the total lack of data on the effectiveness of this intervention plus the potential Respiratory Management harm of repeated attempts at intubation and possible con- tinued bradycardia and hypoxia, this recommendation has Oxygen Administration. The AHA now recommends been dropped. that for preterm infants of Ͻ35 weeks gestation, resusci- Practitioners must remember that the mouth and nose tation be initiated with oxygen of 21–30%. Oxygen level should still be suctioned as with any resuscitation and that can then be titrated as needed. Starting resuscitation with intubation may be appropriate in some circumstances, such a high level of oxygen is not recommended, because there as possible plug in the airway. Intubation should be done is no benefit. Unnecessary exposure to high levels of ox- when appropriate as with any other newborn resuscitation. ygen may be detrimental in both term and preterm infants. Discontinuing or Not Initiating Care Use of CPAP. Nasal CPAP rather than immediate intu- bation is now recommended for preterm infants who are Preterm Infants of <25 Weeks Gestation. This re- breathing spontaneously. Practitioners need to remember mains a difficult area, with no major changes from the last that a self-inflating bag cannot deliver CPAP, and reliable guideline. However, it is important to point out that not 2RESPIRATORY CARE • ●●VOL ● NO ● Copyright (C) 2016 Daedalus Enterprises ePub ahead of print papers have been peer-reviewed, accepted for publication, copy edited and proofread. However, this version may differ from the final published version in the online and print editions of RESPIRATORY CARE RESPIRATORY CARE Paper in Press. Published on March 15, 2016 as DOI: 10.4187/respcare.04787 YEAR IN REVIEW 2015: NEONATAL RESPIRATORY CARE initiating care and discontinuing care are ethically equiv- Off-Label Use of Inhaled Nitric Oxide alent; once initiated, care can be withdrawn. Region-spe- cific guidelines and parental involvement are both very Inhaled nitric oxide (INO) is an important therapy for important. term and near-term infants with persistent pulmonary hy- pertension of the neonate. However, its use in infants at Apgar Score of 0 for 10 Minutes. Resuscitation of an Ͻ34 weeks gestation is off-label and has not been shown infant with no detectable heart rate can sometimes con- to be effective. In an article published this year by Ells- tinue for very long periods. An Apgar score of 0 at 10 min worth et al,12 off-label use of INO was shown to be in- strongly predicts death or very poor outcome. The AHA creasing rather than decreasing. suggests it is reasonable to stop resuscitation at this point. In 2011, the National Institutes of Health released a However, it is important to individualize this decision based consensus statement that discouraged the use of INO in on available information, such as timing of the insult if preterm infants.13 Evidence from most controlled trials as known, adequacy of the resuscitation

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    5 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us