6400-01 CO2 Injector System

6400-01 CO2 Injector System

6400-01 CO2 Injector System The 6400-01 CO2 Injector System allows you to null- balance on chamber CO2 mole fraction, or provide a constant CO2 input. CO2 is controlled by delivering a precisely controlled pure CO2 stream into air that is usually CO2-free. The rate of pure CO2 injection is varied according to demand from the leaf chamber, or from the input CO2 setpoint, whichever approach you specify. With the CO2 injector, independent control of chamber CO2 and H2O is achieved by adjusting the incoming CO2 mole fraction so that the chamber CO2 setpoint is maintained. Subsequently, the controller vents a portion of the air flow in order to maintain chamber humidity. The 6400-01 facilitates measurements at elevated CO2 concentrations and the generation of A-Ci curves. The controller is under complete software control, allowing you to set CO2 levels from the console, or to use AutoPrograms to easily set up automatic measurements at a series of concentrations. For response curves (like the A-Ci curve in Fig. 4), you Photosynthesis System Photosynthesis Photosynthesis System Photosynthesis can null-balance on CO2 in the sample analyzer, rather than the reference analyzer. This is practical only Figure 1. 6400-01 CO2 Injector System; CO2 Source because the sample analyzers are in the sensor head and Assembly (center) and quick-connect desiccant part of the chamber mixing volume. CO2 concentrations and soda lime tubes. LI-6400/6400XT Portable LI-6400/6400XT LI-6400/6400XT Portable LI-6400/6400XT Bypass Valve CO2 Scrubber Air In LI-6400/6400XT Console With LI-6400/6400XT 6400-01 CO2 Injector System Sensor Head Leaf Flow Chamber CO2 Source Assembly Flow Meter Restrictors Liquid CO 75% 2 Pump Sample Exhaust 25% Reference Pure Bypass Valve Analyzers CO2 Mixed CO2 Air Out Flow CO2-Free Flow Rate Air In Desiccant Control CO2 Control Controller CO2 Vent Vent Figure 2. LI-6400/6400XT flow schematic with the 6400-01 CO2 Injector System installed. Pure CO2 is injected into a stream of CO2-free air by the CO2 Flow Controller. The pump runs at a constant speed and the flow rate to the leaf chamber is controlled by the Flow Rate Controller which vents a portion of the flow as needed in order to control chamber humidity. can be held at precise levels because 25 changes are very rapidly detected and ▲ PPFD = 1000 μmol m-2 s -1 compensated for by the 6400-01. ● PPFD = 500 μmol m-2 s -1 ■ PPFD = 250 mol m-2 s -1 ▲ 20 μ ▲ ▲ The 6400-01 CO2 Injector System ▲ consists of an electronic controller, a -1 ▲ 15 ● ● ● CO2 Source Assembly that uses mini- ▲ ● -2 ● cartridges for portable operation, and a ● CO tank fitting for greenhouse or ▲ 2 10 ● ■ ■ ■ laboratory operation. All parts integrate ■ ■ ▲ ■ directly into the standard console with no mol m s ) ● ■ μ 5 ▲ external batteries or control modules. ■ Phaseolus vulgaris L. var. Snap ● A ( ▲●■ The CO2 Source Assembly is designed ■ with robust materials for safe operation. 0 ▲■● CO2 Cylinder Cover -5 0 100 200 300 400 500 600 700 Ci (μmol mol -1 ) Figure 4. Using the 6400-01, A-Ci curves like the three shown above can be generated auto- matically. The instrument’s A-Ci Curve AutoProgram lets you enter the CO2 setpoints and then the 6400-01 controller automatically changes the chamber CO2 concentration to each setpoint and logs data. Chamber humidity and temperature are maintained at constant levels during the measurements. CO2 Cylinder 12g cartridges provide up to 8 hours of (0.07 LPM) to >2000 μmol mol-1 (0.9 operation in the field at CO2 concentra- LPM). -1 -1 WARNING: tions up to 2000 μmol mol . The mini- Air Flow Range: <50 μmol s to >600 Pressure Liquefied Gas -1 SLOWLY cartridges are easily accessible outside μmol s . (Higher altitudes will decrease the instrument, making them easy to the maximum flow rate). Piercing Pin change. CO2 Control Operating Characteris- tics: CO2 mixing ratios are independent of system flow rates. CO2 ratio set point can null with feedback from either the CO2 Cylinder Piercing Block reference or sample IRGA signals. High Pressure WARNING: Vent Air Flow Operating Characteristics: Null balance using H2O concentration in the sample cell or operate with fixed CO2 Source Mounting Block flow based on feedback from the flow meter. Figure 5. 6400-01 disassembled for Operating Temperature Range: cartridge replacement. 0-50 °C. Operating RH: 0-100% Non-condens- Regulator ing. Specifications CO2 Source Assembly: Ordering Information Type: 12g pure liquid CO cylinder. 2 6400-01 CO Injector System. Includes Lifetime of One Cylinder: 8 hours 2 9964-026 CO Source Assembly (mini- after activation regardless of use, due 2 cartridge system), 9964-038 CO to constant usage rate. 2 Controller (includes external tank fittings CO Tank Connector Block: 2 and metal tube compression fittings with Minimum Pressure: 1250 kPa (180 1/8" and 4 mm O.D.), and 3 packs of psig). 9964-037 12g CO Cylinders (25 per Maximum Pressure: 1500 kPa (220 2 pack). Figure 3. CO2 Source Assembly psig). 9964-037 12g CO Cylinders Usage Rate: constant at 10 sccm. 2 ≈ (25 per pack). CO Mixing Range: <50 μmol mol-1 ® 2 4647 Superior Street • P.O. Box 4425 • Lincoln, Nebraska 68504 USA North America: 800-447-3576 • International: 402-467-3576 • FAX: 402-467-2819 • [email protected][email protected] • www.licor.com In Germany and Norway – LI-COR Biosciences GmbH: +49 (0) 6172 17 17 771 • [email protected][email protected] In UK and Ireland – LI-COR Biosciences UK Ltd.: +44 (0) 1223 422102 • [email protected][email protected] 980-06605.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    2 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us