2020 FULL LINE CATALOG PRODUCTS TO SUPPORT DIVE SHOP OPERATIONS TABLE OF CONTENTS 3 6 8 9 TEST EQUIPMENT REGULATOR ACCESSORIES HOOKAHROO SERVICE & MAINTENANCE Flowbenches, workstations, test Regulator, BC and console Portable Surface Supplied Air Tools, O-rings, chemicals and chambers and other products hoses, swivels, adapters and Platforms and Accessories equipment used for the service used in testing regulators, related items. and maintenance of regulators, dive computers and other dive tanks and other dive equipment. related items. 16 18 19 22 AIR FILTRATION COMPRESSORS TANK FILLING COMPRESSED GAS Filters, towers, bulk filter Compressor oils and related Whips, fill attachments and HARDWARE chemicals and related control compressor service items. adapters for filling SCUBA, DIN, Air station hardware, regulators, hardware for breathing air SCBA and many other tank/ valves and fittings for the filtration systems. valve styles. storage and distributions of High Pressure Air. 28 30 PAINTBALL MIXED GAS / NITROX / Whips, adapters and accessories OXYGEN for filling and servicing paint ball Hardware, chemicals and tools tanks and related equipment. used for the creation, handling and analysis of mixed gas, Nitrox and Oxygen. 2 | TABLE OF CONTENTS TEST EQUIPMENT FLOWBENCHES Our top-of-the-line analyzer which is tightness. Air flow rates through tank valves which replaces the mouthpiece. First stage capable of testing all functional parameters or gas manifolds can also be determined. intermediate pressure is sampled through of modern scuba regulators including air To aid in the fine tuning of today’s sensitive the BC hose. Each flowbench now has motor flow rate. This user-friendly machine can regulators, breathing effort readings can be protection circuit which removes power to quickly evaluate the following regulator examined on an expanded scale at the flip of the vacuum motor after several minutes of functions: Air flow rates (up to 30 cu. ft./ a switch. Values to 0.1” of water column can inactivity. This helps prevent motor failures min.), inhalation / exhalation breathing be achieved. No dismantling of regulators is when the motor has been inadvertently left efforts at both initiation and during air flow, required prior to testing: Air from the second on. See data sheet for full specifications. first stage intermediate pressure, lockup stage is injected directly into the machine repeatability and stability, and systemic air through a simple, rubber cup adapter 48251 Compact Deluxe Flowbench with Magnehelic and Manometer 48250 48260 Compact Deluxe Flowbench with Double Magnehelic, European Version Compact Deluxe Flowbench with Double Magnehelic Portable Regulator Tester: This unique device can be used to test SCUBA regulators for inhalation / exhalation effort plus first stage intermediate pressure and lockup stability. All tests can be done without dismantling the regulator. Housed in a tackle-box like carrying case, the tester has a lift-out tray where parts and tools can be carried. This compact and portable device is ideal for field repairs, charter boat operations, classroom demonstrations, or small repair centers which do not require more elaborate equipment. 48100 WWW.GLOBAL-MFG.COM • [email protected] • 512.240.6644 • 800.558.1811 TEST EQUIPMENT | 3 TEST EQUIPMENT 48400 48165 Standard Regulator / Valve Workstation: Digital Benchtop Regulator Tester with Workstations provide controlled air pressure Magnehelic: This compact test apparatus to a test stand where the functions of dive 48155 allows several very important regulator regulators can be checked at sea level functions to be examined with highly conditions. Regulators to be examined Benchtop Breathing Effort Tester: A simple, accurate instrumentation. This tester can are yoked to the test stand valve; where easy-to-use device for quickly testing the check the intermediate pressure, lockup, inter-stage pressure is transmitted to the initial inhalation and exhalation effort of any staging integrity, and initial inhalation / instrumentation via an adapter coupled to the regulator’s second stage. Breathing efforts exhalation of any dive regulator without any BC hose. First stage intermediate pressure, are read directly from a Magnehelic gauge major disassembly. First stage operation can lockup repeatability and stability, and systemic reading ±2 inches water column. be examined by merely attaching the BC air tightness can then be evaluated. A simple hose to the tester. To connect the various probe is then attached to the 2nd stage outlet types of BC hoses, three special adapters while manual breathing is performed, the are provided. Instrumentation features a initial inhalation/exhalation effort (cracking 4.0” diameter breathing effort gauge (2” resistance) can be read with high precision on scale) and a digital readout of a pressure a Magnehelic gauge. A unique “reading lock” transducer (300 psi) for intermediate device momentarily freezes the breathing pressure, protected by an overpressure effort readings on the gauge, so that values valve. Housed in a robust, aluminum, accurate to 0.1” of water column can be desktop style case. 120-240 VAC power obtained! required. 48160 Benchtop Intermediate Pressure Tester: Housed in a handsome plastic case is a 300 psi pressure gauge with 1% accuracy. A series of coupler adapters allow for attachment of different brands of BC hoses. 48401 48166 Regulator / Valve Workstation with Digital Benchtop Regulator Tester with Intermediate Pressure: Magnehelic Similar to the 48400, but with a digital Housed in a robust, aluminum case, this tester readout of intermediate pressure up to 300 is a great item for an entry level technician. psi. The pressure transducer is protected by Incorporates a 300 psi gauge for intermediate a overpressure valve. 120-240 VAC power pressure with a 2” scales magnehelic. required. Comes with same accessories as standard workstation. 4 | TEST EQUIPMENT TEST EQUIPMENT TEST CHAMBERS The current industry standard for testing the water-tight integrity, accuracy, and overall function of depth gauges, watches, dive computers, and certain underwater photographic gear. Each chamber is constructed with a rugged steel structure. The cogged lid with clear acrylic lens is designed for strength and ease of operation. Standard “Depth” chambers have gauges 48101 with 1% accuracy. While, “Instrument” chambers have high accuracy, 0.25% Regulator Probe: A 33” plastic tube and accuracy gauges. See data sheet for more special rubber probe to use with Magnehelic details Gauges for testing the initial breathing Reads to 230 effort of dive regulators. The probe has two 48300 Depth Test Chamber: ft of fresh water with 1% accuracy. different sized ends. The small end will insert directly into many mouthpieces. If this fails, 48305 Extended Range Depth Test remove the mouthpiece and slip the large Chamber: Reads to 370 ft of fresh water with end over the bare flange. 1% accuracy. 48310 Instrument Test Chamber: Reads to 300 feet of salt water with 0.25% accuracy. 48320 Extended Range Instrument Test 43275 Chamber: Reads to 450 feet of salt water with 0.25% accuracy. Regulator Intermediate Pressure Quick- Tester: This 2.5” gauge attaches directly 48320-DRO Instrument Test Chamber to the buoyancy compensator hose for fast with Digital Readout: Equipped with a high checking the intermediate pressure of any accuracy pressure transducer, this unit has regulator first stage without dismantling less than - 0.25% accuracy on a range up to the unit. A manual bleeder vent allows 450 feet of salt water. No more worries about easy cycling of the first stage to test the converting units as the integral touch screen consistency of lockup. The regulator’s displays pressure/depth in the following units: pounds per square inch (psi), feet of fresh 43300 second stage (or octopus) acts as an overpressure valve in case of serious staging water, meters of fresh water, feet of sea water, Magnehelic Gauge ±5 inch scale: failures. Great for field service, charter boats, meters of sea water, BAR, and kilopascals. Considered the standard instrument for and class demos. The touch screen display shows date and time measuring the breathing effort of dive making it easy to record test data. A handy regulators, this Magnehelic Gauge has countdown timer is included. This can be very dual, 5-inch scales to sense both positive helpful for leak testing where a product has to (exhalation) and negative (inhalation) be submerged at ‘depth’ for a given amount pressures. Breathing resistance is measured of time. in inches of water column, equivocally the 48301 Chamber Bulkhead Air Supply: respiratory effort required to draw water one Connects any standard yoke style tank to the inch up a straw! Used with 48101 probe (not Bulkhead Air Shunt. included), this is an essential addition to the dive shop repair department. Order 43302 for 57136 Hoseless Computer Adapter: ±2 inch scale. A combination of a short high pressure regulator hose that accepts the computer's transducer and extends it into the chamber's 48310 48320-DRO water bath allowing the testing of hoseless computers in Global’s Instrument Test Chambers. 48320-AUTO An advanced version of our Instrument Test Chamber: Computerized 57136 controls allows for complete dive profiles to be programmed. Pressure is transmitted through a 0.25% accuracy pressure transducer. See data sheet for more details. 48301 48320-AUTO WWW.GLOBAL-MFG.COM • [email protected] • 512.240.6644 • 800.558.1811 TEST EQUIPMENT | 5 REGULATOR ACCESSORIES 61032 Regulator Hose Multi-Port Expander; REGULATOR HOSES Desc: This adapter connected to the end of a standard regulator hose swivel on our Hookah Standard Low Pressure Breathing Air Hose or a regulator hose. It provides three Hoses: These are 5/16” ID while BC hoses standard, 3/8-24 low pressure ports. These are 1/4” ID. Breathing Air and BC hoses are ports can be used to connect up to three other rated to 400 psi working pressure. All hoses regulator or Hookah hoses. Includes two 3/8-24 are black with an option of yellow, available plugs as standard.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages36 Page
-
File Size-