Review of Bulk Electric System Definition Thresholds

Review of Bulk Electric System Definition Thresholds

Review of Bulk Electric System Definition Thresholds March 2013 3353 Peachtree Road NE Suite 600, North Tower Atlanta, GA 30326 404-446-2560 | www.nerc.com NERC | Review of Bulk Electric System Definition Thresholds | January 2013 1 of 40 Preface and NERC Mission The North American Electric Reliability Corporation (NERC) is an international regulatory authority established to evaluate reliability of the bulk power system in North America. NERC develops and enforces reliability standards; assesses reliability annually via a 10‐year assessment and winter and summer seasonal assessments; monitors the bulk power system; and educates, trains, and certifies industry personnel. NERC is the Electric Reliability Organization for North America, subject to oversight by the U.S. Federal Energy Regulatory Commission (FERC) and governmental authorities in Canada.1 FRCC Florida Reliability Coordinating Council MRO Midwest Reliability Organization NPCC Northeast Power Coordinating Council RFC ReliabilityFirst Corporation SERC SERC Reliability Corporation SPP RE Southwest Power Pool Regional Entity TRE Texas Reliability Entity WECC Western Electricity Coordinating Council NERC assesses and reports on the reliability and adequacy of the North American bulk power system, which is divided into several assessment areas within the eight Regional Entity boundaries, as shown in the map and corresponding table above. The users, owners, and operators of the bulk power system within these areas account for virtually all the electricity supplied in the United States, Canada, and a portion of Baja California Norte, Mexico. 1 As of June 18, 2007, the U.S. Federal Energy Regulatory Commission (FERC) granted NERC the legal authority to enforce Reliability Standards with all U.S. users, owners, and operators of the bulk power system, and made compliance with those standards mandatory and enforceable. In Canada, NERC presently has memorandums of understanding in place with provincial authorities in Ontario, New Brunswick, Nova Scotia, Québec, and Saskatchewan, and with the Canadian National Energy Board. NERC standards are mandatory and enforceable in British Columbia, Ontario, New Brunswick, and Nova Scotia. NERC has an agreement with Manitoba Hydro making reliability standards mandatory for that entity, and Manitoba has adopted legislation setting out a framework for standards to become mandatory for users, owners, and operators in the province. In addition, NERC has been designated as the “electric reliability organization” under Alberta’s Transportation Regulation, and certain reliability standards have been approved in that jurisdiction; others are pending. NERC and NPCC have been recognized as standards‐setting bodies by the Régie de l’énergie of Québec, and Québec has the framework in place for reliability standards to become mandatory and enforceable in that jurisdiction. NERC | Review of Bulk Electric System Definition Thresholds | January 2013 2 of 40 Table of Contents PREFACE AND NERC MISSION .......................................................................................................................................... 2 EXECUTIVE SUMMARY ..................................................................................................................................................... 4 1. INTRODUCTION ........................................................................................................................................................... 5 1.1 PROBLEM STATEMENT ............................................................................................................................................................. 5 1.2 PLANNING COMMITTEE ASSIGNMENTS ........................................................................................................................................ 6 1.3 CONSIDERATIONS FOR TECHNICAL JUSTIFICATION .......................................................................................................................... 6 2. TECHNICAL JUSTIFICATION FOR THE 100 KV BRIGHT LINE ............................................................................................. 7 2.1 ALTERNATIVES TO THE 100 KV BRIGHT LINE ................................................................................................................................. 7 2.2 CONCLUSIONS AND RECOMMENDATION .................................................................................................................................... 12 3. TECHNICAL JUSTIFICATION FOR GENERATOR THRESHOLDS ......................................................................................... 13 3.1. CAPACITY BREAKDOWN ......................................................................................................................................................... 13 3.2 ALTERNATIVES TO THE 20/75 MVA THRESHOLD ........................................................................................................................ 15 3.3 RECOMMENDATION FOR GENERATOR THRESHOLDS ..................................................................................................................... 17 4. TECHNICAL JUSTIFICATION FOR REACTIVE DEVICE THRESHOLD ................................................................................... 19 4.1 BACKGROUND ...................................................................................................................................................................... 19 4.2 ALTERNATIVES TO THE ZERO‐MVAR THRESHOLD UNDER CONSIDERATION ........................................................................................ 19 4.3 CONCLUSION AND RECOMMENDATION ...................................................................................................................................... 20 5. TECHNICAL JUSTIFICATION FOR POWER FLOW OUT OF LOCAL NETWORKS ................................................................. 22 5.1 BACKGROUND ...................................................................................................................................................................... 22 5.2 ALTERNATIVES TO THE ZERO POWER FLOW LIMITATION UNDER CONSIDERATION ............................................................................... 23 5.3 CONCLUSION AND RECOMMENDATION ...................................................................................................................................... 25 5.4 FURTHER CONSIDERATIONS FOR LIMITS ON THE SIZE OF LOCAL NETWORKS ...................................................................................... 25 6. RECOMMENDATIONS ................................................................................................................................................. 27 APPENDIX 1A: REQUEST FROM THE BES SDT TO THE PC ................................................................................................. 28 APPENDIX 1B: AUTHORIZATION AND PROBLEM STATEMENT FROM THE BES DEFINITION SDT (NERC STANDARDS PROJECT 2010‐17, PHASE II) ......................................................................................................................................................... 30 APPENDIX 1C: BES SDT RESPONSE TO PC REPORT (DRAFT 2012 BES DEFINITION REPORT) ............................................... 32 APPENDIX 2: INTERCONNECTION STUDY GUIDELINES ..................................................................................................... 33 APPENDIX 3: OPERATIONAL CONSIDERATIONS TO SUPPORT LOAD LIMIT ON LOCAL NETWORKS .................................... 38 NERC | Review of Bulk Electric System Definition Thresholds | January 2013 3 of 40 Executive Summary In March 2012, the Definition of BES Standard Drafting Team (DBES SDT) asked the Planning Committee (PC) to review some of the thresholds in the Bulk Electric System (BES) definition that the DBES SDT identified within the Phase I BES work and to supply technical justifications for the following thresholds: 1. 100 kV bright‐line transmission threshold (in the core definition) 2. Generation threshold MVA values associated with single‐unit and multiple‐unit facilities (in Inclusions I2 and I4) 3. Reactive power threshold (MVA level) (in Inclusion I5) 4. Power flow allowed out of Local Networks (LN) (in Exclusion E3) After analysis and review, the PC offers the following recommendations to the DBES SDT for consideration: 5. Maintain the 100 kV bright line (core definition). 6. Maintain Inclusions I2 and I4 as currently defined. 7. Maintain Inclusion I5 as currently defined. 8. Use Technical Alternative C, which proposes clarifying changes to the existing Exclusion E3 item (b) as given below in bold: a. Real power flows only in the LN from every point of connection to the BES for the system as planned with all‐lines in service and also for first contingency conditions as per TPL‐001‐2, Steady State & Stability Performance Planning Events P0, P1, and P2, and the LN does not transfer energy originating outside the LN for delivery through the LN to the BES 9. Establish a size limit in the LN definition to prevent the exclusion of large networks that may have a significant impact on Sreliable BE operation. This recommendation is explained in detail in the following section as well as in Appendix 3. The NERC PC discussed and approved the recommendations in this report and its transmittal to the DBES SDT at its December 2012 meeting. Following the meeting, the PC Executive Committee made further changes based on the discussion by the

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    40 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us