64 th metting of SEAC-3 (Day-2) SEAC Meeting number: 64 Meeting Date March 21, 2018 Subject: Environment Clearance for Proposed Residential Scheme at S. No. 12, Talegaon- Dabhade, Pune by Pune Housing and Area Development Board (MHADA) Is a Violation Case: No 1.Name of Project Proposed Residential Scheme by Pune Housing and Area Development Board (MHADA) 2.Type of institution Government 3.Name of Project Proponent Mr. Ashok Kakade 4.Name of Consultant VK:e environmental LLP 5.Type of project MHADA 6.New project/expansion in existing project/modernization/diversification New project in existing project 7.If expansion/diversification, whether environmental clearance Not applicable has been obtained for existing project 8.Location of the project S. No. 12, Talegaon- Dabhade, Pune 9.Taluka Maval 10.Village Talegaon- Dabhade Correspondence Name: Mr. Ashok Kakade Pune Housing & Area Development Board (MHADA), Grihanirman Bhavan, Agarkar Nagar, Pune Room Number: -411001 Pune Housing & Area Development Board (MHADA), Grihanirman Bhavan, Agarkar Nagar, Pune Floor: -411001 Building Name: Grihanirman Bhavan Road/Street Name: Agarkar Nagar Locality: Agarkar Nagar City: Pune 11.Area of the project PMRDA Under Process 12.IOD/IOA/Concession/Plan IOD/IOA/Concession/Plan Approval Number: Under process Approval Number Approved Built-up Area: 13.Note on the initiated work (If Not applicable applicable) 14.LOI / NOC / IOD from MHADA/ Not applicable Other approvals (If applicable) 15.Total Plot Area (sq. m.) 13,000 m2 16.Deductions 1300 m2 17.Net Plot area 11,700 m2 a) FSI area (sq. m.): 32,441.52 m2 18 (a).Proposed Built-up Area (FSI & b) Non FSI area (sq. m.): 5801.76 m2 Non-FSI) SEAC-AGENDA-0000000057c) Total BUA area (sq. m.): 38243.28 Approved FSI area (sq. m.): In process 18 (b).Approved Built up area as per Approved Non FSI area (sq. m.): In process DCR Date of Approval: 01-01-1900 19.Total ground coverage (m2) 2841.60 20.Ground-coverage Percentage (%) (Note: Percentage of plot not open 21.85 to sky) 21.Estimated cost of the project 642900000 22.Number of buildings & its configuration S.D.Aher (Secretary SEAC- SEAC Meeting No: 64 Meeting Date: March 21, Page 1 of Shri. Anil Kale (Chairman III) 2018 59 SEAC-III) Serial Building Name & number Number of floors Height of the building (Mtrs) number 1 Building A P+12 37.7 2 Building B LP+L Stilt+U Stilt+12 43.5 3 Building C LP+L Stilt+U Stilt+12 43.5 4 Building D P+12 37.7 No. of tenements : 790 23.Number of Residential Tenants: 3950 tenants and shops No. of shops: NA 24.Number of expected residents / Residential users : 3950 Commercial Users :NA users 25.Tenant density 607Tenements/hectare, 3038 Tenants/hectare per hectare 26.Height of the building(s) 27.Right of way (Width of the road Width of the road is 18 m wide. Nearest fire station: Talegaon Dabhade MIDC Fire station from the nearest fire Nearest Fire Station Distance : Approximately 4.66 Km station to the proposed building(s) 28.Turning radius for easy access of fire tender movement from all 9 m around the building excluding the width for the plantation 29.Existing Not applicable structure (s) if any 30.Details of the demolition with Not applicable disposal (If applicable) 31.Production Details Serial Product Existing (MT/M) Proposed (MT/M) Total (MT/M) Number 1 Not applicable Not applicable Not applicable Not applicable 32.Total Water Requirement SEAC-AGENDA-0000000057 S.D.Aher (Secretary SEAC- SEAC Meeting No: 64 Meeting Date: March 21, Page 2 of Shri. Anil Kale (Chairman III) 2018 59 SEAC-III) Source of water Talegaon Dabhade Nagarparishad Fresh water (CMD): 365.5 Recycled water - 177.7 Flushing (CMD): Recycled water - 16 Gardening (CMD): Swimming pool 0 make up (Cum): Dry season: Total Water Requirement (CMD) 559.2 : Fire fighting - Underground water 200 tank(CMD): Fire fighting - Overhead water 80 tank(CMD): Excess treated water 295.1 Source of water Talegaon Dabhade Nagarparishad Fresh water (CMD): 365.5 Recycled water - 177.7 Flushing (CMD): Recycled water - 0 Gardening (CMD): Swimming pool 0 make up (Cum): Wet season: Total Water Requirement (CMD) 543.2 : Fire fighting - Underground water 200 tank(CMD): Fire fighting - Overhead water 80 tank(CMD): Excess treated water 311.1 Details of Swimming Not applicable pool (If any) 33.Details of Total water consumed Particula Consumption (CMD) Loss (CMD) Effluent (CMD) rs Water Require ExistingSEAC-AGENDA-0000000057Proposed Total Existing Proposed Total Existing Proposed Total ment Not Not Not Not Not Not Not Not Not Domestic applicable applicable applicable applicable applicable applicable applicable applicable applicable S.D.Aher (Secretary SEAC- SEAC Meeting No: 64 Meeting Date: March 21, Page 3 of Shri. Anil Kale (Chairman III) 2018 59 SEAC-III) Level of the Ground Level of ground water table: Pre monsoon : - 9 m bgl Post monsoon : - 7 water table: m bgl Size and no of RWH tank(s) and Not applicable Quantity: Location of the RWH Not applicable tank(s): Quantity of recharge 6 34.Rain Water pits: Harvesting Size of recharge pits 2.5 m x 2.5 m x 2m (RWH) : Budgetary allocation Rs.9,00,000/- (Capital cost) : Budgetary allocation Rs. 25,000/- (O & M cost) : Residential: Details of UGT tanks Domestic water compartment: - 548.2 m3 if any : Fire Fighting compartment : - 200 m3 Flushing:- 177.7 m3 The storm water drainage will be designed according to contours. The Natural water storm water collected through the storm water drains of adequate drainage pattern: capacity will be led to recharge pits & overflow will be connected to 35.Storm water existing Storm water Drain drainage Quantity of storm 70m3/day water: Size of SWD: 450 mm Sewage generation 488.8 in KLD: STP technology: MBBR Capacity of STP 1 No. of 490 kld (CMD): Sewage and Location & area of On ground, area : 250 sqm Waste water the STP: Budgetary allocation 1,15,00,000/- (Capital cost): Budgetary allocation 16,50,000/- (O & M cost): 36.Solid waste Management - Dry waste (Kg/day): 08 kg/day -Wet waste (Kg/day): 12 kg/day -Total Waste generation: Waste generation in waste generated:20kg/day the Pre ConstructionSEAC-AGENDA-0000000057 and Construction Disposal of the The Construction waste generated during construction shall be phase: construction waste segregated, reused on site and surplus shall be led to scrap dealers for debris: recycling Dry waste: 790 kg/day Wet waste: 1185 kg/day Hazardous waste: NA Waste generation Biomedical waste (If in the operation NA Phase: applicable): STP Sludge (Dry 55 kg/day sludge): Others if any: NA S.D.Aher (Secretary SEAC- SEAC Meeting No: 64 Meeting Date: March 21, Page 4 of Shri. Anil Kale (Chairman III) 2018 59 SEAC-III) Dry waste: will be handed over to SWaCH Wet waste: will be treated in Organic Waste Converter (OWC). Hazardous waste: NA Mode of Disposal Biomedical waste (If NA of waste: applicable): STP Sludge (Dry Dried sludge from STP will be used as manure. sludge): Others if any: NA Location(s): on ground Area Area for the storage of waste & other 14 sqm requirement: material: Area for machinery: 58 sqm Budgetary allocation Capital cost: Rs. 29,75,000/- (Capital cost and O&M cost): O & M cost: 7,37,564/- 37.Effluent Charecterestics Serial Inlet Effluent Outlet Effluent Effluent discharge Parameters Unit Number Charecterestics Charecterestics standards (MPCB) Not 1 Not applicable Not applicable Not applicable Not applicable applicable Amount of effluent generation Not applicable (CMD): Capacity of the ETP: Not applicable Amount of treated effluent Not applicable recycled : Amount of water send to the CETP: Not applicable Membership of CETP (if require): Not applicable Note on ETP technology to be used Not applicable Disposal of the ETP sludge Not applicable 38.Hazardous Waste Details Serial Description Cat UOM Existing Proposed Total Method of Disposal Number Not Not Not Not Not 1 Not applicable Not applicable applicable applicable applicable applicable applicable 39.Stacks emission Details Height Internal Serial Fuel Used with from Temp. of Exhaust Section & units Stack No. diameter Number Quantity ground Gases (m) SEAC-AGENDA-0000000057level (m) 0.0762 1 1 DG set of 50 kvA 7.47 kg/hr 1 1.5 408 degree C mm 40.Details of Fuel to be used Serial Type of Fuel Existing Proposed Total Number 1 Not applicable Not applicable Not applicable Not applicable 41.Source of Fuel Not applicable 42.Mode of Transportation of fuel to site Not applicable S.D.Aher (Secretary SEAC- SEAC Meeting No: 64 Meeting Date: March 21, Page 5 of Shri. Anil Kale (Chairman III) 2018 59 SEAC-III) Total RG area : 2628.14 m2 No of trees to be cut 0 : Number of trees to 175 43.Green Belt be planted : Development List of proposed Refer below list native trees : Timeline for completion of Till operation phase plantation : 44.Number and list of trees species to be planted in the ground Serial Characteristics & ecological Name of the plant Common Name Quantity Number importance A large size tree with dense foliage provides shade along roads, wood 1 Syzygium cumini Jambhul Tree 10 is resistant and attracts a variety of birds A columnar, evergreen tree, grows 2 Millingtonia hortensis IndianCork Tree 06 well in both dry and moist regions.Ornamental value. State flower tree of Maharashtra Lagerstromia flos- Medium sized tree, beautiful 3 Tamhan 05 regineae purple flowers, grows well in both dry and humid climate Medium size gracious deciduous , flowering tree which prefers 4 Jacaranda mimosifolia jacaranda 10 moderate climate. Medicinal and ornamental value Large tree good for stopping soil 5 Pongamia pinnata Karanj 18 erosion along canal banks A medium Large size hardy 6 Azadirachta indica Neem 25 tree.stand in drought condition.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages59 Page
-
File Size-