Increasing the Efficiency of Astigmatism Testing with the Topcon

Increasing the Efficiency of Astigmatism Testing with the Topcon

By Scott Fleming, OD Increasing the effi ciency of astigmatism testing with the Topcon CV-5000S J. Scott Fleming Optometrists, Torrace, CA he nature of astigmatism necessitates the and frustration that accompanies the traditional use of several tests to identify its presence Jackson cross cylinder test. Unlike the Jackson test, T and severity. While the corneal imaging which requires patients to compare sequential red techniques used in astigmatism assessment have and green framed-images, the Topcon simultane- undergone huge advancements in recent years, ous cross cylinder test presents the red and green- the determination of astigmatic refractive error framed images simultaneously in a split screen. As has remained at a stand-still. Indeed, the Jackson such, the optometrist can assess views of the front cross cylinder test has been the ‘go-to’ method and the rear of the Jackson cross cylinder at the for determining astigmatism-related refractive same time, rather than one after another. And as the errors for more than 100 years.1 However, like patient sees both images together, he or she is more many long-standing traditions, the test possesses confi dent that he or she has correctly identifi ed the some flaws. sharper image and the time wasted on going back to previous images to clarify the answer given by the The nature of the problem patient is avoided in totality. Patients and optometrists often report that the Jack- son cross cylinder test is unnecessarily complicated. Speed, accuracy and flexibility As the test relies on the classic question: “Which is The CV-5000S makes the measurement of cylin- better; one or two?” patients can struggle to remem- der power and axis faster and more accurate in ber the difference between successive images. This is particularly diffi cult when the images in question have a very similar level of blurriness. In such situ- ations, a patient may fi nd him or herself resorting to guesswork to avoid the embarrassment of repeat- edly asking for images to be shown again. Topcon Medical Systems Inc. (Oakland, NJ) has developed an automated vision testing system, the CV-5000S, which features a novel simultaneous Figure 1: The Topcon CV-5000S Automated Vision cross cylinder test. The Topcon simultaneous cross Tester features a touch-screen controller for automated control of the refractive process and a compact phorop- cylinder test removes the element of guesswork ter head for added patient and operator comfort. © 2012 Topcon Medical Systems, Inc. astigmatic patients. But the system does not force In addition to its unique astigmatism refrac- those accustomed to the Jackson cross cylinder tion test, the CV-5000S also offers the benefit test to use the new test; instead it offers the op- of PC-compatible controller software, provision tion of switching between both forms of the test. of a 21-point refraction and an automatic pho- However, the time savings and increased patient ropter head that allows high-speed lens rotation satisfaction provided by the Topcon simultaneous during eye examinations. Its compact design is cross cylinder test is likely to convert even the fifty percent smaller than previous phoropter most avid Jackson cross cylinder test fan. models and fits comfortably on a desktop. This not only allows the user to easily observe the patient’s expression during the refraction, but it “The Topcon simultaneous cross cylinder test also eliminates the discomfort (typically shoulder removes the element of guesswork and frus- pain) that many optometrists experience when tration that accompanies the traditional Jack- manipulating a phoropter. Further user discom- son cross cylinder test.” fort and inconvenience is avoided by the system’s automated action. Its design ensures that the user I started using the CV-5000S shortly after its never has to reach for the projector. He or she market-release in 2005. In that time, I have found simply touches the screen to select the desired that the simultaneous image-viewing offered by test and in doing so, the chart changes and the the simultaneous cross cylinder test saves me test lenses (if required) automatically drop into about an hour per day. By improving my patients’ place. The device’s LED illumination also in- understanding of the image comparisons they are creases user convenience by providing adequate asked to make during the examination, I have lighting for the near test chart, without the need found that the astigmatic refraction examination for additional external illumination. And as the now progresses more smoothly than in the past. system is electronic medical record (EMR)- With the Topcon simultaneous cross cylinder test compatible, it speeds up workflow and enhances I get to my end point about six minutes earlier overall practice efficiency. than with the Jackson cross cylinder test. So, if I see ten astigmatic patients in one day, that’s an extra hour saved by the end of the day. Additional features The device also has the added benefit of improv- ing patient care. Virtually every optometrist knows that if a patient doesn’t like a particular test they will attend clinic as infrequently as possible. This means that by the time an optom- etrist sees a patient who has been delaying their astigmatism examination, their vision may have worsened significantly. Simply eliminating the Figure 2: The Topcon cross cylinder test presents the confusion that dissuades patients from having the red and green-framed images simultaneously in a split Jackson cross cylinder test can make them more screen, allowing the patient to more easily identify the diligent clinic attendees. clearer image. © 2012 Topcon Medical Systems, Inc. A turning point for optometry The simultaneous cross cylinder test presents a CV-5000S much-needed opportunity to advance the assess- Computerized Vision Tester ment of astigmatism-related refractive error in the same direction as the rest of the optometric field. As eye specialists continue to search for effective ways to manage patients and encourage Refraction Meets patient proactivity, the CV-5000S provides an ad- Automation ditional tool for achieving this aim. And the fact that both patients and optometrists can reap ben- efits from this faster and more enjoyable method of testing provides further reason to move cross cylinder testing into the 21st century. References 1. A. Brookman KE. The Jackson crossed cylinder: historical per spective. J Am Optom Assoc. 1993 May;64(5):329-31). Scott Fleming, OD is a practicing optometrist and founder of J. Scott Fleming Optometrists in Torrance, CA. Topcon Medical Systems, Inc. 111 Bauer Drive, Oakland, NJ 07436 P: 800.223.1130 | www.topconmedical.com © 2012 Topcon Medical Systems, Inc..

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    3 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us