Seca 264 Manual

Seca 264 Manual

seca 264 English CONTENTSEnglish 1. Description of device . .42 5.2 Additional functions (menu). 62 1.1 Congratulations! . .42 Navigate within the menu . 62 1.2 Intended use . .42 Activate acoustic signals (bEEP) . 63 Restore factory settings (rSEt). 63 2. Safety information. .42 Set display backlighting (LCd) . 64 2.1 Basic safety precautions. .42 Switch over length units (Unit) . 65 2.2 Safety information in this manual . 43 6. The seca 360° wireless network . 66 2.3 Handling (rechargeable) batteries . .44 6.1 Introduction . 66 seca wireless groups . 66 3. Overview . .45 Channels . 67 3.1 Controls . .45 Detection of devices . 67 3.2 Display elements . .47 6.2 Operating the device in a 3.3 Information on rating plate . .47 wireless group (menu). 68 3.4 Menu structure . .48 Activate wireless module (system) . 68 4. Before you get started … . .49 Set up wireless group (Lrn) . 68 4.1 Scope of supply . .49 Activate automatic transmission 4.2 Assembling the device . .50 (ASend). 70 Install second column element .50 Select print option (APrt) . 71 Installing the head slide . .51 Set time (Time) . 71 Install the third column element.51 7. Cleaning. 72 Installing the push-in scale . .52 4.3 Mounting the device on the wall . 53 8. What to do if …? . 72 Installing the wall brackets . .53 8.1 Faults and their correction . 72 Installing the slot bolts. .54 8.2 Change the batteries of the Positioning the device in the head slide. 74 wall brackets. .55 Installing the foot mat . .55 9. Maintenance. 75 4.4 Connecting the power supply . .56 10. Technical data . 75 4.5 Calibrate head slide . .56 11. Accessories . 76 Automated calibration . .56 Calibrating manually . .58 12. Disposal. 76 5. Operate head slide . .59 12.1 Disposal of device . 76 12.2 Batteries. 76 5.1 Measure height. .59 Start measuring height . .59 13. Warranty . 77 Continuous display of measured result (Hold) . .60 Perform relative measurements (zero). .60 Transmit measured results to wireless receivers . .61 Switch off head slide. .61 • 41 1. DESCRIPTION OF DEVICE 1.1 Congratulations! By purchasing the seca 264 length measuring rod you have acquired an extremely accurate and robust device. For more than 170 years, seca has devoted its experience to health care and, as the market leader in many countries, is constantly setting new standards with its innovative weighing and measurement developments. 1.2 Intended use The seca 264 length measuring rod is mainly used in hospitals, doctors' surgeries and inpatient care facilities, in accordance with national regulations. The length measuring rod is used to determine a baby's size. The seca 360° wireless network allows the measured results to be transmitted wirelessly to a seca wireless printer or a PC equipped with the seca analytics 105 software and the PC equipped with the seca 360° Wireless USB adapter 456. 2. SAFETY INFORMATION 2.1 Basic safety precautions • Please take note of the information in this user manual. • Keep the user manual with the declaration of conformity in a safe place. • Do not expose the device to any violent impacts. • Only use the type of battery specified (see “Connecting the power supply” on page 56). • Have the scales serviced regularly (see “Maintenance” on page 75). • Make sure that maintenance and repair are only carried out by an authorised service partner. 42 • English • Make sure you only use genuine seca accessories and spare parts. Otherwise the warranty provided by seca will become null and void. • Make sure RF equipment such as mobile phones is kept at a minimum distance of approx. 1metre to prevent incorrect measurements or interference with the wireless transmission. 2.2 Safety information in this manual DANGER! Used to identify an extremely hazardous situation. If you fail to take note of this information, serious irreversible or fatal injuries will occur. WARNING! Used to identify an extremely hazardous situation. If you fail to take note of this information, serious irreversible or fatal injuries may result. CAUTION! Used to identify a hazardous situation. If you fail to take note of this information, minor to moderate injuries may result. ATTENTION! Used to identify possible incorrect usage of device. If you fail to take note of this information, you may damage the device or the measured results may be incorrect. NOTE Includes additional information about use of the device. Safety information • 43 2.3 Handling (rechargeable) batteries The device is supplied with 4 batteries, type AA (Mignon). This type of battery is not rechargeable. Please take note of the following safety information. WARNING! Personal injury with improper handling. Batteries contain harmful substances which may explode if not handled properly. − Do not try to recharge such batteries. − Do not expose (rechargeable) batteries to heat. − Do not burn (rechargeable) batteries. − If acid is leaking out, avoid contact with the skin, eyes and mucous membranes. Rinse affected areas with plenty of clean water and seek medical help at once. ATTENTION! Damage to device and malfunctions with improper handling − Only use the type of (rechargeable) battery specified (see “Connecting the power supply” on page 56). − When replacing (rechargeable) batteries, always replace a complete set at a time. − Do not short-circuit (rechargeable) batteries. − If you do not use the device for a long period of time, remove the batteries (incl. rechargeable batteries). This prevents acid from leaking into the device. 44 • English 3. OVERVIEW 3.1 Controls 6 5 7 4 8 9 3 2 1 Overview • 45 No. Control Function 1 Head slide Control for determining height Keypad, head Controls for performing length/height measurements and 2 slide for configuring the device Frankfurt Pull-out ruler for aligning the head according to the so- 3 measure called “Frankfurt Horizontal”. Display, head Display element of the head slide for measured results 4 slide and for configuration Battery Designed to take battery pack with 4 type AA batteries 5 compartment, (mignon), 1.5 V head slide Start key, head slide: 6 Switch head slide on and off Arrow key (hold/zero) • During measuring - Press briefly: activate Hold function - Hold down: set zero point 7 •In the menu: - Select submenu, select menu item - Set value (press briefly: value is changed by 1, press for longer time: value is changed until key is released) Enter key (send/print): • During measuring (if wireless network is set up) - Press briefly: send measured result to ready to receive devices (multifunctional display, wireless printer, PC with USB wireless module) 8 - Hold down: print out measured result (wireless printer) •In the menu: - Confirm selected menu item -Save set value • Holds the head slide in position 9 Brake button • Pressed to move the head slide 46 • English 3.2 Display elements A Symbol Meaning A Battery power low. 3.3 Information on rating plate Text/Symbol Meaning Model Model number Type Type designation Ser.No. Serial number Refer to user manual Type B electromedical device Class II fully-insulated appliance For USA: FCC ID device licensing number issued by the US Federal Communications Commission (FCC) For Canada: IC device licensing number issued by the Industry Canada authority Device complies with EC standards and directives. Symbol of the FCC (USA) Do not dispose of device in household waste Overview • 47 3.4 Menu structure Additional functions are available in the device's menu. This allows you to optimally configure the device to suit your own needs. Details are give from page 62 and from page 68. • on Beep • off CAL No Yes Auto • Channel 1 (C1) rF* Learn Group (ID) • Channel 2 (C2) Stop Reg. Devices (Mo) • on • Channel 3 (C3) Autosend • off • on *seca 360° wireless network: System • off Group (ID): • on Max. three seca wireless groups: 0, 1, 2 Autoprint • off Maximum configuration per wireless group: • Year - 1 set of baby scales • Month Time • Day - 1 set of personal scales • Hour - 1 length measuring rod • Minute - 1 wireless printer Reset - 1 PC with USB wireless module • Short LCD Duration • Long Channel (C1, C2, C3): - Three channels per wireless group • 50 % (in total, (in total 9 channels) Brightness • 100% - Channel numbers: 0 - 99 • off - Only use each channel number once • cm - Recommended spacing: 30 Unit • ft:in Example of configuration: - Group 0: C1 0, C2 30, C3 60 End - Group 1: C1 10, C2 40, C3 70 - Group 2: C1 20, C2 50, C3 80 Navigation:Navigation: (Note: no spaces in display) CallMenü upaufrufen: menu: Devices detected (Mo): + - 1: personal scales - 2: height-measuring rod -3: wireless printer - 4: PC with USB wireless module - 7: baby scales 48 • English 4. BEFORE YOU GET STARTED … 4.1 Scope of supply b c d e a f g h i j n m l k No. Component Qty. a Bottom column element with heel stop 1 b Column element 2 c Threaded rod 2 d Upright connector 1 e End cap 1 f Elongated nut 1 g Plain washer 1 h Nut 1 i Decorative cap 1 Wall-mounting kit consisting of - Wall brackets j - Slot bolts 2 - Screws M6 x 60 - Standard rawl plugs k Head slide with Frankfurt measure, complete 1 l Battery holder with 4 batteries, size AA 1 m Push-in scale 1 n Foot mat 1 Calibration rod, not illustrated 1 User manual, not illustrated 1 Cover, Frankfurt measure, not illustrated 1 Toolkit, not illustrated 1 Before you get started … • 49 4.2 Assembling the device The heel stop is mounted on the first column element in the factory. Perform the remaining assembly with the assistance of another person. Due to the large overall height, we recommend placing the components on the floor and not uprighting the device until it is fully assembled.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    39 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us