Ring Main Unit SF6 Gas Insulated Ring Main Units RMU Ring Main Unit SF6 Gas Insulated Ring Main Units

Ring Main Unit SF6 Gas Insulated Ring Main Units RMU Ring Main Unit SF6 Gas Insulated Ring Main Units

RMU Ring Main Unit SF6 Gas Insulated Ring Main Units RMU Ring Main Unit SF6 Gas Insulated Ring Main Units 24kV LFL type Based on maximizing efficiency and reliability of the power technology helps offering optimized solutions for your environment Susol RMU is enable to install on medium voltage distribution network and mainly used for protection of transformers in compact substations. It is used for medium voltage distribution in compact substations, small buldings, residential housing complex, large shopping malls, airports, wind power, and solar power comprising medium voltage networks. The concept of Susol RMU is offering a choice of other switch-fuse combination or Circuit Breaker with relay for protection of the transformer. 02 | LSIS Co., Ltd. Contents 24kV LCL type 24kV Extensible type 36kV LCL type Certified quality STL (The Short-Circuit Testing Liaison, KERI), ISO 9001, ISO 14001 LSIS has integrated a functional organization into each of its units, the main purpose of which is to check quality and ensure the adherence to standards. Routine quality check While producing Susol RMU, various routine tests are taken for product capacity. Tested items are as shown follows. •Filling pressure check •Tightness check •Manual and motor operation check •Dielectric check Contents •Contact resistance check •OCR operation check Features 05 Ordering Information 07 Configuration (Non-Extensible RMU) 08 Configurations (Extensible RMU) 11 Main characteristics 12 Types and diagrams 13 Major components 14 Accessories 20 Dimensions 25 LSIS Co., Ltd. | 03 RMU Non-Extensible: CB Feeder (LCL) & Fuse Feeder (LFL) RMU Extensible: LBS Feeder (L), CB Feeder (C) & Fuse Feeder (F) 24kV LFL type 24kV LCL type 04 | LSIS Co., Ltd. Features Susol RMU is a compact ring main unit combining all MV functional units to enable to supply and protect transformers on the secondary distribution network. Susol RMU can be supplied in various and different configurations suitable for most switching applications in 12 / 17.5 / 24kV / 36kV distribution networks Technology Durability and usefulness •Metal enclosed unit for indoor installation and type tested. •Metal enclosed tank is hermetically sealed, it means this is •Insulated by SF6 Gas. independent of environmental effects such as dirt, small insects, •Maintenance free and easy installation. moisture and so on. •Independent of climate. •Load break switch operating is possible in the front of Ring Main Unit. •ON-OFF-Earth, 3-position load break switch •All switching operations can be made safely to personnel because of interlocking system that operates automatically according to the Safety switch position by the operator. •Approachable and operable safety in the presence of power •No requirement of recharging SF6 gas until its service life. in the cables. •Remote operation available in case of using motor operating mechanism and RTU. •Clear indication of operation status via mimic diagram on front panel. •HRC power fuse will trip the mechanism automatically by a fuse striker pin connected to mechanism in the event of fault happening. • Fully automatic interlocking system. - Operation is only possible in case door is totally closed. - Fuse compartment is only accessible when Load break Saving cost switch is earthed. • No maintenance is required other than replacement of HRC Power - Voltage detector to check whether cables are lined or not. Fuse after installation. •Internal arc withstand is tested for the operator safety in •Compact design that requires minimum space to install and operate case of accident current occur. locally is main advantage especially where the space is limited. 24kV Extensible type 36kV LCL type LSIS Co., Ltd. | 05 Features Intelligent application Network remote control for DAS / SCADA Equipped with RTU (remote termination unit), the Susol RMU switchgear can implement intelligent application. Connecting all the IRMUs by a communication network, it enable to monitor and control the switchgear remotely, locate and isolate faultautomatically as well as the system recovery. This will dramatically reduce the affected area and duration of blackout, and realize the high reliability and excellent power quality. System configuration Susol RMU equipped with RTU provides all the functions needed to operate the MV network in real time Control center Server Dispatcher (MMI) Printer DAU Hard Copier OTS RMU with RTU RTU Small customer Power plant Substaion RMU with RTU Pol switch Large customer RTU(Remote Terminal Unit) Equipped with RTU (Remote Terminal Unit), the Susol RMU switchgear can implement intelligent application. Connecting all Susol RMU with communication network, it enables to monitor and control the switchgear remotely. The Remote Terminal Unit (RTU) collects data from field instruments & sensors and transmits the information to the Supervisory Control and Data Acquisition System (SCADA) installed in a central control room through communication systems and lines, and receives control commands from the telemeter telecontrol system to conduct online controls in real time. 06 | LSIS Co., Ltd. Ordering Information SF6 Gas Insulated Ring Main Units Non-Extensible RMU 1. CB Feeder RMU RC B 36 6 6 6 0 Rated current Rated current Rated Type Operation Code Rated voltage Code Code Code Code Oder type Code (Main) (T-OFF) frequency RC Manual B 36kV 36 SKD S 630A 6 630A 6 60Hz 6 LC AC 110V A1 24kV 24 CKD C 50Hz 5 LCL AC 220V A2 17.5kV 17 Complete 60 / 50Hz 0 product 0 LLCL DC 110V D1 12kV 12 LCCL DC 220V D2 2. Switch-Fuse Feeder RMU RF B 36 6 6 6 0 Rated current Rated current Rated Type Operation Code Rated voltage Code Code Code Code Oder type Code (Main) (T-OFF) frequency RF Manual B 24kV 24 SKD S 630A 6 200A 2 60 / 50Hz 0 LF AC 110V A1 17.5kV 17 CKD C LFL AC 220V A2 12kV 12 Complete Product 0 LLFL DC 110V D1 LFFL DC 220V D2 3. LBS Feeder RMU LR B 24 6 0 0 0 Rated current Rated current Rated Type Operation Code Rated voltage Code Code Code Code Oder type Code (Main) (T-OFF) frequency LR Manual B 24kV 24 SKD S 630A 6 N/A 0 60 / 50Hz 0 LLL AC 110V A1 17.5kV 17 CKD C LLLL AC 220V A2 12kV 12 Complete product 0 DC 110V D1 DC 220V D2 Extensible RMU R B 24 6 6 6 0 Rated current Rated current Rated Type Operation Code Rated voltage Code Code Code Code Oder type Code (Main) (T-OFF) frequency R Manual B 24kV 24 SKD S 630A 6 630A 6 60Hz 6 L AC 110V A1 17.5kV 17 CKD C 200A 2 50Hz 5 C AC 220V A2 12kV 12 Complete 60 / 50Hz 0 product 0 F DC 110V D1 DC 220V D2 LSIS Co., Ltd. | 07 Ring Main Unit Configurations (Non-Extensible RMU) 12/17.5/24kV Non-Extensible CB Feeder RMU 2 LBS & 1 CB-DS in single chamber. L: LBS (Load Break Switch) ❶ 3-position Load Break Switch rated 630A and ❷ less for load breaking and earthing ❸ C: VCB (Vacuum Circuit Breaker) Circuit Breaker with 21kA interrupting capacity for the transformer and line protection ❹ Horizontal Cable Bushing in Front ❻ ❺ ❼ ❽ ❶ Name plate ❾ ❷ Circuit Breaker operation ❸ Ring S / W operation ❹ Ring S / W operation ❺ Disconnector S/W Earth operation ❻ Pressure gauge ❼ Voltage Indicator ❽ Disconnector S / W operation ❾ Cable compartment 08 | LSIS Co., Ltd. SF6 Gas Insulated Ring Main Units Information of model name L: LBS L: LBS (Load Break Switch) (Load Break Switch) Quantity of LBS L F/C L L F/C F : Load Break Switch-Fuse combination Quantity of F/C system C : Vacuum Circuit Breaker withdisconnecting switch Diagram, standard types LCL ( 2L1C ) LFL ( 2L1F ) 36kV Non-Extensible CB Feeder RMU 2 LBS & 1 Switch-Fuse in single chamber. L: LBS (Load Break Switch) 3-Position load break switch with a rating of ❶ 630A or less for load break and earthing ❷ C: VCB (Vacuum Circuit Breaker) ❸ 20kA circuit breaker with interrupting capacity for the transformer and line protection ❹ Horizontal Cable Bushing in Front ❺ ❻ ❼ ❽ ❶ Name plate ❷ Circuit breaker operation ❾ ❸ Main circuit operation ❹ Ring S / W operation ❺ DS earth operation ❻ Pressure gauge ❼ Voltage indicator ❽ DS main circuit operation ❾ Cable compartment LSIS Co., Ltd. | 09 Ring Main Unit Configurations (Non-Extensible RMU) 12/17.5/24kV Non-Extensible Switch-Fuse Feeder RMU 2 LBS & 1 Switch-Fuse in single chamber. L: LBS (Load Break Switch) 3-position Load Break Switch rated 630A and ❽ less for load breaking and earthing ❶ F: Switch Fuse ❷ (Load Break Switch-Fuse combination) 200A switch-fuse combination for transformer ❸ protection Horizontal Cable bushing in Front ❹ ❺ ❻ ❼ ❶ Ring S / W Earth operation ❷ T-off operation ❸ Ring S / W operation ❹ Pressure gauge ❺ Voltage Indicator ❻ Cable compartment ❼ Fuse compartment ❽ Name plate 10 | LSIS Co., Ltd. LR(1L1R) LR(1L1R)LLL (3L) LR(1L1R)LLL (3L) LLLLLR(1L1R) (4L) LLL (3L) LLLL (4L)LLL (3L) LLLL (4L) LLLL (4L) RC(1R1C) RC(1R1CLC(1L1C) )LRC(1R1CLC(1L1C) )LRC(1R1CCL (2L1C)) LC(1L1C)LCL (2L1C)LC(1L1C)LLLCL (3L1C) CL (2L1C) LLCL (3L1C)CL (2L1C) LCCL (2L2C) LLCL (3L1C) LCCL (2L2C)LLCL (3L1C) LCCL (2L2C) LCCL (2L2C) RF(1R1F) RF(1R1F)LF (1L1F) RF(1R1F)LF (1L1F) LFLRF(1R1F) (2L1F) LF (1L1F) LFL (2L1F)LF (1L1F) LLFL (3L1F) LFL (2L1F) LLFL (3L1F)LFL (2L1F) LFFL (2L2F) LLFL (3L1F) LFFL (2L2F)LLFL (3L1F) LFFL (2L2F) LFFL (2L2F) Configurations (Extensible RMU) SF6 Gas Insulated Ring Main Units Information of model name Diagram, standard types RLRLRLCFRLCFCFCF R: Riser C: CB R L C F (Vacuum Circuit Breaker with disconnecting switch) R L C F L: LBS F: Fuse (Load Break Switch) (Load Break Switch-Fuse combination) LBS Feeder(L) CB Feeder(C) Switch–Fuse Feeder(F) L: LBS C: VCB F: Switch Fuse (Load Break Switch) (Vacuum Circuit Breaker) (Load Break Switch–Fuse 3-position Load Break Switch rated 630A Circuit Breaker with 21kA Combination) and less for load breaking and earthing interrupting capacity for the 200A switch-fuse combination for transformer and line protection transformer protection ❶ ❶ ❶ ❷ ❷ ❷ ❺ ❼ ❺ ❿ ❸ ❻ ❽ ❸ ❸ ❾ ❹ ❹ ❹ ❶ Pressure gauge ❺ Ring S / W Earth operation ❾ Disconnector S / W operation ❷ Name plate ❻ Ring S / W operation ❿ Fwitch - Fuse operation ❸ Voltage detactor ❼ Circuit Breaker operation Fuse compartment ❹ Cable compartment ❽ Disconnector S / W Earth operation LSIS Co., Ltd.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    28 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us