MISCELLANEOUS CONTROLS MANUAL & DIGITAL TIME SWITCHES 93000, TS-200 SERIES DESCRIPTION The Marktime 93000 Series Wall Box Manual Time Switch is a spring-wound, manually set time switch for the control of electrical current. Interchangeable with standard toggle switch- es to turn circuits either off or on at the end of a preset time period, the 93000 Series is ideally suited for new installations or retrofit projects. FEATURES • White and ivory plates and knobs included with each MISCELLANEOUS CONTROLS time switch • Heavy motor loads without the need of contactors •Time ranges from minutes to 12 hours, all with ±5% •Rotary knob operation accuracy • Available to turn circuits off or on, with or • Easy-to-install two-wire design to fit into standard without manual hold override feature single-gang wall box • UL listed, CUL ORDERING INFORMATION MODEL DESCRIPTION MODEL DESCRIPTION No Hold Previous With Hold Previous 93000 SERIES 93501C (90005/90539) 0-15 Min N.O./N.C. 93511C (90012/90543) 0-15 Min N.O./N.C. (w/hold) 93502C (90006/90032) 0-30 Min N.O./N.C. 93512C (90011/90037) 0-30 Min N.O./N.C. (w/hold) ELECTRICAL RATING 93503C (90008/90024) 0-60 Min N.O./N.C. 93513C (90010/90038) 0-60 Min N.O./N.C. (w/hold) 20A 125 VAC 1 hp 93504C (90281/90540) 0-120 Min N.O./N.C. 10A 277 VAC 93505C (90007/90017) 0-6 Hour N.O./N.C. 93515C (90017/90548) 0-6 Hour N.O./N.C. (w/hold) 93506C (90001/90015) 0-12 Hour N.O./N.C. 93516C (90015/90014) 0-12 Hour N.O./N.C. (w/hold) 7A 125 VAC tungsten 93507C (90240/90547) 0-4 Hour N.O./N.C. 93517C (90542/90546) 0-4 Hour N.O./N.C. (w/hold) Weight: 0.4 lb (182g) DESCRIPTION The Watt Stopper® InteliSwitch® TS-200 Series Digital Time Switch automatically turns the load off after a preset amount of time. The load can be turned off anytime during the timer's countdown by pushing the on/off button. The TS-200 Series has four user-adjustable features: Time-Out Delay The timer can be adjusted to hold the load on from five min- utes to 12 hours. This is adjusted by setting the DIP switch located on the left side of the unit. Time Scrolling In situations where the load needs to be held on for a different amount of time than the preset time-out period, time scrolling allows the user to manually and temporarily override the time- WIRING out period without adjusting the DIP switch. Neutral Flash Option Load Ground +24 VDC or (red) If this option is on, the load will flash once, one minute before Ground(capped) 24 VAC 60Hz the time-out period expires. Set this option on the DIP switch. (black) Hot (black) (red) Return Beeper Option If this option is on, the timer will beep every five seconds dur- Isolated Relay (green) Normally Closed ing the last minute of the time-out period. Set this option on !Very Important! (orange) Common the DIP switch.Archived Document120 VAC Ground - Green (yellow) Normally Open 277 VAC Ground - Green/Yellow SPECIFICATIONS TS-200 TS-200-24 TS-200 TS-200-24 Voltage 120/277 VAC/60 Hz 24 VDC, 24 VAC/60 Hz ORDERING INFORMATION Load rating 800W tungsten Isolated relay or ballast @ 120 VAC SPDT, 1A @ 30V MODEL DESCRIPTION 1200W ballast @ 277 VAC Time adjust 5, 15, 30 min., 1,3, 6, 9, 12 hrs TS-200 Digital Time Switch, 120/277 VAC (both models) TS-200-24 Digital Time Switch, 24 VAC/DC Color White White Weight 0.4 lb (182g) 0.4 lb (182g) KELE • www.kele.com 417 USA 901-937-4900 • International 901-382-6084.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages1 Page
-
File Size-