PROJECT PROFILE Soldier Field Stadium WJE Corrosion Mitigation Testing for Historic Concrete Elements | Chicago, IL CLIENT As a result of reinforcing steel corrosion, portions of the stadium developed significant concrete Chicago Park District distress. Mitigating the potential hazard of spalling overhead concrete requires regular inspections. In conjunction with an extensive renovation and partial reconstruction of the BACKGROUND stadium, the Chicago Park District wanted to evaluate various corrosion mitigation schemes to Soldier Field is home to the ensure long-term protection of the historic concrete elements to remain in the rebuilt stadium, National Football League’s Chicago including the main girders over the Exhibition Hall and the coffered ceilings of the colonnades. Bears. The stadium was originally constructed in the 1920s and was later named and dedicated as a SOLUTION memorial to fallen American Based on extensive experience with corrosion-related concrete distress, soldiers. The main girders in the WJE selected several corrosion mitigation techniques and implemented stadium’s Grand Concourse were trial installations in the field. These included spray-applied and admixed constructed as part of the original corrosion inhibitors; realkalization; arc-sprayed zinc in a passive cathodic structure using a concrete mix of protection system; and mechanically attached zinc sheets and discrete relatively low strength and high zinc anodes in a passive cathodic protection system. permeability. As a result primarily WJE installed corrosion probes and performed nondestructive testing to of concrete carbonation, these evaluate the performance of each approach. This information was then members have been subject to used to make predictions regarding long-term performance and life- extensive reinforcing steel cycle costs. WJE also provided recommendations for repair of the corrosion and concrete spalling. historic concrete elements. The concrete coffered ceilings of the colonnades have experienced similar deterioration due to high chloride ion concentrations attributed to the use of chloride- containing additives during original construction. www.wje.com .

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    1 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us