National Fire Protection Association Report

National Fire Protection Association Report

National Fire Protection Association Report http://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPara... Public Input No. 12-NFPA 497-2014 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this recommended practice and should be considered part of the recommendations of this document. 2.2 NFPA Publications. National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471. NFPA 30, Flammable and Combustible Liquids Code, 2012 edition. NFPA 33, Standard for Spray Application Using Flammable or Combustible Materials, 2011 edition . NFPA 34, Standard for Dipping, Coating, and Printing Processes Using Flammable or Combustible Liquids, 2011 edition . NFPA 35, Standard for the Manufacture of Organic Coatings, 2011 edition . NFPA 36, Standard for Solvent Extraction Plants, 2009 edition 2013 . NFPA 45, Standard on Fire Protection for Laboratories Using Chemicals, 2011 edition . NFPA 55, Compressed Gases and Cryogenic Fluids Code, 2010 edition 2013 . NFPA 58, Liquefied Petroleum Gas Code, 2011 edition 2014 . NFPA 59A, Standard for the Production, Storage, and Handling of Liquefied Natural Gas (LNG), 2009 edition 2013 . ® ® NFPA 70 , National Electrical Code , 2011 edition 2014 . 2.3 Other Publications. 2.3.1 ANSI Publications. American National Standards Institute, Inc., 25 West 43rd Street, 4th Floor, New York, NY 10036. ANSI/ISA-RP12.12.03, Recommended Practice for Portable Electronic Products Suitable for Use in Class I and II, Division 2, Class I, Zone 2 and Class III, Division 1 and 2 Hazardous (Classified) Locations , 2002. 2.3.2 API Publications. American Petroleum Institute, 1220 L Street, NW, Washington, DC 20005-4070. API RP 500, Recommended Practice for Classification of Locations for Electrical Installations at Petroleum Facilities rd Classified as Class I, Division 1 and Division 2, 2002. (Reaffirmed, November 2002.) 3 edition, 2008 . API RP 505, Recommended Practice for Classification of Locations for Electrical Installations at Petroleum Facilities Classified as Class I, Zone 0, Zone 1, and Zone 2, 2002, reaffirmed 2013 . 2.3. 3 2 ASHRAE Publications. American Society of Heating, Refrigeration and Air-Conditioning Engineers, Inc., 1791 Tullie Circle NE, Atlanta, GA 30329-2305. ASHRAE 15 , Safety Code for Mechanical Refrigeration , 2007 & 34 , Safety Standard for Refrigeration Systems , 2013 with 2014 errata . 2.3. 4 3 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM D 323, Standard Method of Test for Vapor Pressure of Petroleum Products (Reid Method), 2008. 2.3. 5 4 CGA Publications. Compressed Gas Association, 4221 Walney Road, 5th Floor, Chantilly, VA 20151-2923. ANSI/ CGA G2.1, Safety Requirements for the Storage and Handling of Anhydrous Ammonia, 1999. 1 of 59 11/26/2014 1:14 PM National Fire Protection Association Report http://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPara... 2.3. 6 5 IEC Publications. International Electrotechnical Commission, 3, rue de Varembé, P.O. Box 131, CH-1211 Geneva 20, Switzerland. IEC TR3 60079-20, Electrical apparatus for explosive gas atmosphere—Part 20: Data for Flammable gaes and vapors, relating to the use of electrical apparatus , 1996. 2. -1 , Explosive Atomspheres —Part 20 -1 : Material Characteristics for Gas and Vapor Classification - Test Methods and Data , 2012 . 2.3.6 ISA Publications The International Society of Automation, 67 T.W. Alexander Drive, P.O. Box 12277, Research Triangle Park, NC 27709. ISA-RP12.12.03, Standard for Portable Electronic Products Suitable for Use in Class I and II, Division 2, Class I Zone 2 and Class III, DIivision 1 and 2 Hazardous (Classified) Locations , 2011 . 2. 3.7 Other Publications. Merriam-Webster’s Collegiate Dictionary, 11th edition, Merriam-Webster, Inc., Springfield, MA, 2003. 2.4 References for Extracts in Recommendations Sections. NFPA 30, Flammable and Combustible Liquids Code, 2012 edition . NFPA 59A, Standard for the Production, Storage, and Handling of Liquefied Natural Gas (LNG), 2009 edition 2013 . ® ® NFPA 70 , National Electrical Code , 2011 edition 2014 . Statement of Problem and Substantiation for Public Input Current editions referenced, updated titles of IEC and ISA standards, and eliminated the ANSI section due standard development by IEC. Related Public Inputs for This Document Related Input Relationship Public Input No. 13-NFPA 497-2014 [Chapter C] Submitter Information Verification Submitter Full Name: Aaron Adamczyk Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Thu Jun 12 12:34:37 EDT 2014 Committee Statement Resolution: FR-3-NFPA 497-2014 Statement: Current editions referenced, updated titles of IEC and ISA standards, and eliminated the ANSI section due to standard development by IEC. ASHRAE 34 is not referenced in NFPA 497. 2 of 59 11/26/2014 1:14 PM National Fire Protection Association Report http://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPara... Public Input No. 5-NFPA 497-2014 [ Section No. 2.3.3 ] 2.3.3 ASHRAE Publications. American Society of Heating, Refrigeration and Air-Conditioning Engineers, Inc., 1791 Tullie Circle NE, Atlanta, GA 30329-2305. ASHRAE 15, Safety Code Standard for Mechanical Refrigeration Systems , 2007 2013 . Additional Proposed Changes File Name Description Approved 497_Ferguson_ASHRAE_PI5-7.pdf PI Form Statement of Problem and Substantiation for Public Input There are outdated references to ASHRAE Standard 15. This proposes to update the reference title and year where it appears in this standard. Submitter Information Verification Submitter Full Name: STEVEN FERGUSON Organization: ASHRAE Street Address: City: State: Zip: Submittal Date: Wed Jan 29 14:13:08 EST 2014 Committee Statement Resolution: FR-3-NFPA 497-2014 Statement: Current editions referenced, updated titles of IEC and ISA standards, and eliminated the ANSI section due to standard development by IEC. ASHRAE 34 is not referenced in NFPA 497. 3 of 59 11/26/2014 1:14 PM NFPA Public Input Form NOTE: All Public Input must be received by 5:00 pm EST/EDST on the published Public Input Closing Date. FOR OFFICE USE ONLY For further information on the standards-making process, please contact the Codes and Standards Administration at 617-984-7249 or visit www.nfpa.org/codes. Log #: For technical assistance, please call NFPA at 1-800-344-3555 Date Rec’d: Date Name Steve Ferguson Tel. No. 678-539-1138 Company ASHRAE Email [email protected] Street Address 2540 Drew Valley Rd City Atlanta State GA Zip 30319 Please indicate organization represented (if any) ASHRAE 1. (a) Title of NFPA NFPA® 497 NFPA No. & Year 497-2012 Standard Recommended Practice for the Classification of Flammable Liquids, Gases, or Vapors and of Hazardous (Classified) Locations for Electrical Installations in Chemical Process Areas (b) Section/Paragraph 2.3.3, C2.2 2. Public Input Recommends (check one): new text revised text deleted text 3. Proposed Text of Public Input (include proposed new or revised wording, or identification of wording to be deleted): [Note: Proposed text should be in legislative format; i.e., use underscore to denote wording to be inserted (inserted wording) and strike- through to denote wording to be deleted (deleted wording).] 2.3.3 ASHRAE Publications. American Society of Heating, Refrigeration and Air-Conditioning Engineers, Inc., 1791 Tullie Circle NE, Atlanta, GA 30329-2305. ASHRAE 15, Safety Code Standard for Mechanical Refrigeration Systems, 20072013. C.2.2 ASHRAE Publications. American Society of Heating, Refrigeration and Air-Conditioning Engineers, Inc., 1791 Tullie Circle, NE, Atlanta, GA 30329-2305. ASHRAE 15, Safety Code Standard for Mechanical Refrigeration Systems, 20072013. All references to ASHRAE Standard 15 should be editorially corrected from the old title to the new title throughout the document. Example Footnote f of Table 4.4.2 fFor classification of areas involving ammonia, see ASHRAE 15, Safety Code Standard for Mechanical Refrigeration Systems, and ANSI/CGA G2.1, Safety Requirements for the Storage and Handling of Anhydrous Ammonia 4. Statement of Problem and Substantiation for Public Input: (Note: State the problem that would be resolved by your recommendation; give the specific reason for your Public Input, including copies of tests, research papers, fire experience, etc. If more than 200 words, it may be abstracted for publication.) There are outdated references to ASHRAE Standard 15. This proposes to update the reference title and year where it appears in this standard . 5. Copyright Assignment (a) I am the author of the text or other material (such as illustrations, graphs) proposed in the Public Input. (b) Some or all of the text or other material proposed in this Public Input was not authored by me. Its source is as follows: (please identify which material and provide complete information on its source) I hereby grant and assign to the NFPA all and full rights in copyright in this Public Input (including both the Proposed Text and the Statement of Problem and Substantiation). I understand that I acquire no rights in any publication of NFPA in which this Public Input in this or another similar or analogous form is used. Except to the extent that I do not have authority to make an assignment in materials that I have identified in (b) above, I hereby warrant that I am the author of this Public Input and that I have full power and authority to enter into this assignment. Signature (Required) PLEASE USE SEPARATE FORM FOR EACH PUBLIC INPUT To: Secretary, Standards Council National Fire Protection Association 1 Batterymarch Park · Quincy, MA 02169-7471 OR Fax to: (617) 770-3500 OR Email to: [email protected] 1/30/2014 National Fire Protection Association Report http://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPara... Public Input No. 20-NFPA 497-2014 [ Section No. 2.3.4 ] 2.3.4 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM D 323, Standard Method of Test for Vapor Pressure of Petroleum Products (Reid Method), 2008 08(2014) .

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    74 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us