Ultrasound in Labor and Delivery

Ultrasound in Labor and Delivery

Mini-Review Fetal Diagn Ther 2010;27:61–67 Received: January 5, 2010 DOI: 10.1159/000287588 Accepted: January 5, 2010 Published online: February 18, 2010 Ultrasound in Labor and Delivery a b Francisca S. Molina Kypros H. Nicolaides a Department of Obstetrics and Gynaecology, Fetal Medicine Unit, University Hospital ‘Virgen de las Nieves’, b Granada , Spain; Harris Birthright Research Centre for Fetal Medicine, King’s College Hospital, London , UK Key Words Extensive evidence over the last 30 years has demon- Ultrasound ؒ Labor ؒ Induction of labor ؒ Progress of labor ؒ strated the value of ultrasound in the prenatal diagnosis Instrumental delivery of fetal abnormalities and in the assessment of fetal growth and wellbeing. Recent studies suggest that ultra- sound may play an important role in the prediction of the Abstract time of onset and the progress of labor and in this article Ultrasound may play an important role in the management we review the evidence in favor of the use of ultrasound of labor and delivery. Induction of labor is a common obstet- in the control of labor and delivery. ric intervention, performed in about 20% of pregnancies. Pre-induction cervical length, measured by transvaginal so- nography, has been shown to have a significant association Ultrasound before Induction of Labor with the induction-to-delivery interval and the risk for cesar- ean section. In the management of labor there is extensive Induction of labor is a common obstetric intervention, evidence that digital pelvic examination does not provide performed in about 20% of pregnancies [1] . However, accurate assessment of the position and descend of the fetal about 20% of women having induction of labor need a head both during the first but also in the second stage of cesarean section for delivery either because of failed in- labor. Several recent studies using both two- and three- duction, failure to progress in labor or fetal distress [2] . dimensional ultrasound have now described objective mea- Several studies have examined a variety of maternal sures of progression of the fetal head during labor. In instru- and fetal factors as well as screening tests to predict the mental deliveries an important determinant of a successful outcome of labor induction. One meta-analysis by Crane and safe use of vacuum and forceps is the correct determina- [3] reported that certain characteristics of the woman tion of the fetal head position and appropriate application (parity, age, weight, height and body mass index) and of of the instrument. However, ultrasound studies have shown the fetus (birth weight and gestational age) are useful pre- that digital examination before instrumental delivery fails to dictors with parous young women who are tall and of low identify the correct fetal position in a high proportion of cas- weight having a higher rate of induction success. Fetuses es. The use of ultrasound is of crucial importance in perform- with a lower birth weight or increased gestational age are ing a safe operative delivery and can help in the prediction also associated with increased induction success. Pre-in- of whether a vaginal delivery would be successful. duction cervical length, measured by transvaginal so- Copyright © 2010 S. Karger AG, Basel © 2010 S. Karger AG, Basel Dr. Francisca S. Molina 1015–3837/10/0272–0061$26.00/0 Fetal Medicine Unit, Department of Obstetrics and Gynaecology Fax +41 61 306 12 34 University Hospital ‘Virgen de las Nieves’ E-Mail [email protected] Accessible online at: Avda. Fuerzas Armadas s/n, ES–18012 Granada (Spain) www.karger.com www.karger.com/fdt Tel. +34 958 02 00 85, Fax +34 958 02 06 53, E-Mail fsoniamolina @ gmail.com nography, has been shown to have a significant associa- cations for delivery during the 41st week a policy of delay- tion with the induction-to-delivery interval and the risk ing induction of labor by 7–10 days would reduce sub- for cesarean section. There is evidence that pre-induction stantially the rate of induction for prolonged pregnancy. cervical length and the position of the fetal occiput in ad- The extent to which such policy could reduce the overall dition to maternal characteristics, including parity, ges- rate of cesarean section without an increase in perinatal tational age, maternal age, and body mass index, provides death can only be answered by randomized studies. useful prediction of the likelihood of cesarean section [4– 6] . For example, the odds of cesarean section increases by about 10% with each increase of 1 mm in cervical length Ultrasound to Define Fetal Head Position and above 20 mm and the odds are about 75% lower in mul- Progression during Labor tiparae, compared to nulliparae with the same cervical length [7] . A series of models, incorporating sonographic There is extensive evidence that digital pelvic exami- and demographic characteristics, have been developed nation for the determination of fetal head position during that can classify women into high and low risk groups for labor is not accurate. Sherer et al. [11, 12] reported a dis- cesarean section and provide individual patient predic- crepancy in the assessment of the fetal occipital position tions for outcome of induction of labor [8] . of at least 45° between digital examination and transab- The main indication for induction of labor is post- dominal ultrasound in 53 and 39% of patients in the first term pregnancy because in such cases the risk of intra- and second stage of labor, respectively. Akmal et al. [13] uterine and postnatal death is increased from 2.4 per reported that digital pelvic examination failed to deter- 1,000 pregnancies at 40 weeks to 5.8 at 43 weeks. In the mine the fetal head position in 34% of laboring women, management of the post-term pregnancies, induction of and incorrectly determined head position in 51% of pa- labor reduces perinatal mortality when compared with tients in whom the position could be defined. The rate of expectant management [9] . The traditional approach to correct identification of the fetal position by digital ex- the management of prolonged pregnancy is to undertake amination increased with cervical dilatation, and if there delivery during the 41st week of gestation. Rao et al. [10] was absence rather than presence of caput. Souka et al. reported the results of a new approach whereby an ultra- [14] showed that assessment of the fetal head position by sound-based assessment is undertaken at the end of the digital examination was not possible in 61% of cases in 40th week or during the 41st week of gestation and unless the first stage and in 31% in the second stage of labor. Dif- there is evidence of a specific medical or obstetric indica- ficulty in assessing the position was more likely if the oc- tion induction of labor is delayed by 7–10 days. The study ciput was posterior in comparison to anterior and in the demonstrated that a policy of delaying induction resulted maternal right in comparison to the left side. When as- in spontaneous onset of labor and delivery in more than sessment by vaginal examination was possible, fetal head 80% of cases. In addition, the rate of cesarean section for position assessment by digital examination was accurate failure to progress or fetal distress was about 20% in the in 31% of the cases in the first stage and in 66% of cases total population, including 15% in those with spontane- in the second stage of labor. ous onset of labor and 36% in those requiring induction The inaccuracy of clinical examination during labor of labor. The chance of spontaneous onset of labor was has also been demonstrated in the descent of the head higher in parous than nulliparous women and was in- over the different planes of the maternal pelvis. Dupuis et versely related to maternal body mass index and cervical al. [15] investigated the reliability of transvaginal assess- length. The chance of vaginal delivery was higher in ment of fetal head station by using a newly designed birth those with spontaneous than induced onset of labor, in simulator. A fetal head mannequin was placed in 1 of the parous than nulliparous women, and in white than black 11 American College of Obstetricians and Gynecologists women, and was inversely related to maternal body mass (ACOG) stations in a birth simulator equipped with real- index and cervical length. time miniaturized sensor. The operators (32 residents An ultrasound-based prolonged pregnancy clinic can and 25 obstetricians) then determined head position clin- identify previously undiagnosed problems, such as breech ically. Mistakes in the ACOG position occurred in 50– presentation that may benefit from elective cesarean sec- 88% of cases for residents and in 36–80% of cases for ob- tion or oligohydramnios and fetal growth restriction for stetricians, depending on the position. Regarding ‘group’ which early delivery with close intrapartum monitoring errors, classified as high, mid-pelvis, low and outlet, the would be needed. In those with no specific medical indi- mean ‘group’ error was 30% (95% CI 25–35%) for resi- 62 Fetal Diagn Ther 2010;27:61–67 Molina /Nicolaides Ultrasound transducer Pubic bone Fetal head Spine Fig. 1. Ultrasound image and drawing to demonstrate the fetal head direction described as the angle between a vertical line from inferior apex of the symphysis (yellow line) and another line drawn perpendicular to the wid- est diameter of the fetal head (red line). dents and 34% (95% CI 27–41%) for obstetricians and fetal head is a sign of good prognostic value for vaginal alarmingly, from the group errors, the misdiagnosis of a delivery contrary to a downward or horizontal direction station as representing a mid-pelvic station rather than a of the head.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    7 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us