Acta Gymnica, vol. 46, no. 2, 2016, 74–81 doi: 10.5507/ag.2016.004 Functional clinical typology of the foot and kinematic gait parameters Jitka Marenčáková1,*, Zdeněk Svoboda2, Ivan Vařeka2,3, and František Zahálka1 1Faculty of Physical Education and Sport, Charles University, Prague, Czech Republic; 2Faculty of Physical Culture, Palacký University Olomouc, Czech Republic; and 3Faculty of Medicine, Charles University, Hradec Králové, Czech Republic Copyright: © 2016 J. Marenčáková et al. This is an open access article licensed under the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/). Background: The foot plays a key role in a standing posture, walking and running performance. Changes in its structure or function may alter upper segments of kinematic chain which can lead to formation of musculoskel- etal disorders. Although functional clinical typology provides a complex view of foot kinesiology there is a lack of knowledge and evidence about influences of different foot types on human gait. Objective: The aim of the study was to analyse differences of kinematic gait parameters of lower extremity joints and pelvis between functional clinical foot types in healthy young men. Methods: Three-dimensional kinematic analysis by the Vicon Motion Capture MX System device in synchronization with 2 Kistler force platforms was used to obtain kinematic data from 18 healthy men (mean age 23.2 ± 1.9 years). The functional clinical foot type was clinically examined and sorted into 3 basic foot type groups – forefoot varus (FFvar), rearfoot varus (RFvar) and forefoot valgus (FFvalg). Peak angular values and range of an angular displacement in all of three movement planes were analysed for pelvis, hip, knee and ankle joint. For statistical analysis of kinematic gait parameters differences between foot types Mann Whitney U test at a statistical significance level p < .05 and Cohen’s coefficient d for effect size were used. Results: This study showed that functional clinical foot type can affect kinematic parameters of gait in the joints of the lower limb and pelvis. Significant differences were presented in the FFvar in comparison with other two foot type groups with middle and high size of effect. The most alterations were observed in pelvis area and in a sagittal plane of movement. Neverthe- less, significant differences between FFvalg and RFvar foot types were not noticed. Conclusions: Functional clinical foot typology provides one of the possible methods to describe foot structure and function. Our results showed that foot type could alter gait. Forefoot varus foot type has more significant influence on kinematic gait parameters then other foot types. These effects should be considered by clinicians during examination of musculoskeletal system disorders especially in lower extremities. Keywords: foot, functional typology, gait cycle, kinesiology, 3D kinematic analysis Introduction impulse to move forward (Scott, Menz, & Newcombe, 2007). It is also involved in managing and maintain- The human foot is the only segment of the lower limb ing stability and balance (Cote, Brunet, Gansneder, & that provides direct contact with the ground during Shultz, 2005; Lewit & Lepšíková, 2008). standing, walking and running (Tiberio, 1988). Its Foot typology is a clinical concept that targets to complex anatomical structure is designed to ensure simplify the anatomical complexities of the human both the function of static support and simultaneously foot (Hillstrom et al., 2013). Currently there are dynamic locomotor function (Dylevský, 2009). That several methods for determining foot type but most puts claim at a certain phase of gait cycle to be flexible of them evaluate foot morphology in its static posi- enough for absorbing the shock during initial contact tion. Although no universal consensus exists for the and adapt to uneven terrain and at a different phase ideal method of the foot type classification it is pos- conversely be sufficiently rigid when one creates an sible to divide them into the basic categories – visual non-quantitative clinical inspection (e.g. arch height, navicular prominences, position of rearfoot), anthro- * Address for correspondence: Jitka Marenčáková, Sport Re- search Centre, Faculty of Physical Education and Sport, Charles pometric values (e.g. valgus index, navicular drop, University, José Martího 31, 162 52 Praha 6, Czech Republic. rearfoot angle), footprint parameters (e.g. arch index) E-mail: [email protected] and radiographic evaluation (e.g. calcaneal inclination Functional clinical foot typology and kinematic gait parameters 75 angle) (Billis, Katsakiori, Kapodistrias, & Kapreli, differently influence the kinematic chain of the lower 2007; Buldt et al., 2013; Hillstrom et al., 2013; Ozer, extremity and pelvis. Thus the aim of this study was to 2012; Razeghi & Batt, 2002). clarify whether there are differences in the kinematic In the 60’s of 20th century Merton Root came up parameters of the joints of the lower extremity and with a new, so-called functional clinical typology of pelvis during gait cycle between different functional the foot depending on a position of rearfoot relative to clinical foot types. shin and forefoot relative to rearfoot (Tiberio, 1988). He described the foot primarily as a dynamic complex and took into account the position of the loaded and Methods unloaded foot. He introduced the clinical term neutral position of the subtalar joint (NPSJ) which was pro- Participants gressively modified into a position where subtalar joint Fifty men, students of the Faculty of Physical Culture, (SJ) is neither prone nor supine (Root, Orien, Weed, Palacký University Olomouc, volunteered to take a & Hughes, 1971). Root, his colleagues and followers part in the study but only 18 participants (mean age described four basic types called intrinsic foot defor- 23.2 ± 1.9 years, body mass 77.8 ± 8.1 kg, and body mities – forefoot varus, forefoot valgus and rearfoot height 181.0 ± 5.1 cm) had completed all procedures. varus, and their sub-types and defined the normal Each participant filled out an entry questionnaire about foot (Buchanan & Davis, 2005). Root’s typology has his health status, so we excluded those individuals who brought a new insight into the kinesiology, pathokine- have had an injury of lower limb, pelvis or spine and siology and biomechanics of the foot and it became persons with sensory nerve damage or mental illnesses. the basis of compensatory, not a corrective, orthoses Prior to the study, participants were fully informed concept using struts and wedges, which aims to pre- about the study design and they signed an informed vent self-compensation mechanisms of the lower limbs consent form. The project was approved by the Ethics segments with their negative consequences (Eslami, Committee of the Faculty of Physical Culture, Palacký Tanaka, Hinse, Farahpour, & Allard, 2006). On the University Olomouc. other hand, it is still criticized for low reliability in determining foot type and there is still no general defi- Measurement nition of neutral position of subtalar joint (Cornwall et The three-dimensional gait analysis was supported by al., 2004; Lee, 2001; Razeghi & Batt, 2002). However, the Vicon Motion Capture MX System (Vicon Motion despite questioning Root’s definitions and methods for Systems, Oxford, United Kingdom). This system was determining NPSJ, it is still the gold standard for a ref- based on 7 infrared cameras Vicon MX (T10, 1 mega- erence position of the foot and it is used for the design pixel) connected to the MX Ultranet controlling hard- and a production of high efficiency functional braces ware. Kinetic data were collected using 2 Kistler force (Harradine, Bevan, & Carter, 2006; Miller & McGuire, platforms 60 × 40 cm (type 9286AA, Kistler Instru- 2000). mente, Winterthur, Switzerland). This equipment was In all types of the foot there are compensatory connected to the Vicon MX Control in order to guar- mechanisms that are required to achieve the necessary antee the synchronization of Vicon MX Ultranet with contact of the foot during the stance phases of the gait the Vicon Motion Capture System. cycle. Joints of the foot work with the other joints of Force platforms were placed between the wooden the lower limb within the open and closed kinematic floorboards so that their edges weren’t above the floor chains and it is known that the associated movements and did not therefore affect the natural gait cycle. exist (Betsch et al., 2011). Inadequate settings of the Kinematic and kinetic data were recorded at 200 Hz motion segments of the lower limbs thus may gradually frequency. The placement of the 16 spherical reflective lead to an asymmetric load musculoskeletal structures markers (14 mm diameter) on the subject’s anatomical and thereby cause pathology of the musculoskeletal landmarks was in accordance with PlugInGait model system (Billis et al., 2007; Curran & Dananberg, 2005; (Vicon Motion Systems, Oxford, United Kingdom). Hsi, 2016; Vařeka, 2004), e.g. deformities of the toes The calibration procedure was developed in accor- (Vařeka & Vařeková, 2009), patellofemoral pain syn- dance with the Vicon technical specifications. For drome (Barton, Levinger, Crossley, Webster, & Menz, static calibration we used calibration L-frame and for 2012) or even pain in the lumbar spine (Michaud, dynamic calibration we used calibration wand. Cam- 1997). eras placement was in accordance with the manufac- Variability in kinematics of the foot is high
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages8 Page
-
File Size-