Savona Water Master Plan

Savona Water Master Plan

Savona Water Master Plan Thompson Nicola Regional District April 2018 Project No. 379-491 201-2079 Falcon Rd | Kamloops BC | V2C 4J2 | www.true.bc.ca | tel 250.828.0881 | fax 250.828.0717 Distribution List # of Hard Copies PDF Required Association / Company Name 1 1 TNRD Revision Log Revision # Revised by Date Issue / Revision Description 1 R Wall Jan 22, 2018 First Draft 2 R Wall Apr 20, 2018 Final Report Submission Report Prepared By: Report Reviewed By: Rob Wall, P. Eng. Dave Underwood, P. Eng. Project Engineer Project Engineer R:\Clients\300-399\379\379-491\05 Reports\379-491-TNRD-Savona Water Master Plan-April 2018.docx SAVONA WATER MASTER PLAN THOMPSON NICOLA REGIONAL DISTRICT – APRIL 2018 Table of Contents Executive Summary.................................................................................................................vi 1.0 Background ....................................................................................................................1 1.1 Water Demands........................................................................................................... 3 1.2 Water Quality Analysis................................................................................................. 5 1.2.1 Source ...................................................................................................................5 1.2.2 Comprehensive Water Testing...............................................................................5 1.2.3 Turbidity.................................................................................................................6 1.2.4 Bacteriological Testing...........................................................................................7 1.3 Regulatory Agency Certificates and Approvals ............................................................ 9 1.3.1 Interior Health ........................................................................................................9 1.3.2 Water Licence........................................................................................................9 2.0 Capacity and Condition of Water Intake .....................................................................10 2.1 Kamloops Lake Intake ................................................................................................10 3.0 Treatment / Disinfection...............................................................................................17 3.1 Disinfection System ....................................................................................................17 4.0 Controls and Electrical ................................................................................................19 5.0 Water Storage Reservoir..............................................................................................21 6.0 Water Distribution System...........................................................................................24 7.0 Rights of Way ...............................................................................................................38 8.0 Improvement Plan ........................................................................................................39 8.1 General.......................................................................................................................39 8.2 Water Collection .........................................................................................................39 8.2.1 Future Intake Pump .............................................................................................39 8.3 High Lift Pump Station ................................................................................................40 8.4 Treatment ...................................................................................................................41 8.4.1 Filtration Deferment (UV Disinfection)..................................................................41 8.4.2 Upgrade to Water Treatment by Filtration ............................................................43 8.5 Water Distribution System...........................................................................................51 8.5.1 Distribution Improvements ...................................................................................51 SAVONA WATER MASTER PLAN i THOMPSON NICOLA REGIONAL DISTRICT – APRIL 2018 8.5.2 Dedicated Main to Reservoir................................................................................55 8.5.3 Decommission Ballou Road Reservoir.................................................................57 8.5.4 Water Meters .......................................................................................................58 8.6 Planning......................................................................................................................60 8.6.1 Source to Tap Assessment..................................................................................60 8.6.2 Emergency Response Plan..................................................................................60 8.6.3 Water Conservation Plan Implementation ............................................................61 9.0 Cost Summary..............................................................................................................62 APPENDICES Appendix A – Comprehensive Water Analysis Appendix B – Permit To Operate Appendix C – Water Modeling Results SAVONA WATER MASTER PLAN ii THOMPSON NICOLA REGIONAL DISTRICT – APRIL 2018 List of Tables Table 1-1: Savona Community Growth ...................................................................................... 4 Table 1-2: Summary of Bacteriological Tests By Interior Health................................................. 7 Table 6-1: Existing Watermains ................................................................................................25 Table 6-2: Existing Watermain Appurtenances..........................................................................26 Table 6-3: Calculated Water Pressure vs Target Water Pressure .............................................35 Table 6-4: Observed Hydrant Flows Prior to 2017 System Upgrade vs Modelled Flows ...........35 Table 8-1: Estimated Intake Improvement Cost.........................................................................39 Table 8-2: Estimated Chemical Storage Room Cost .................................................................40 Table 8-3: Estimated Treatment Costs – UV Disinfection..........................................................42 Table 8-4: Slow Sand Filters .....................................................................................................43 Table 8-5: Rapid Gravity Filters – Direct Filtration.....................................................................44 Table 8-6: Rapid Gravity Filters –Package Sedimentation / Rapid Gravity Filtration..................44 Table 8-7: Membrane Filters .....................................................................................................45 Table 8-8: Estimated Treatment Cost – Membrane Filtration Option.........................................47 Table 8-9: Water Distribution System Improvement Costs ........................................................54 Table 8-10: Estimated Cost to Decommission Ballou Road Reservoir ......................................57 Table 8-11: Estimated Water Metering Costs............................................................................59 Table 9-1: Intake and Treatment Upgrades...............................................................................62 Table 9-2: General Water Improvements ..................................................................................62 Table 9-3: Distribution System Improvements...........................................................................63 List of Figures Figure 1-1: Location Plan ........................................................................................................... 2 Figure 1-2: Flow Trend - Savona Community Water System...................................................... 3 Figure 1-3: Turbidity Trend - Savona Community Water System................................................ 6 Figure 2-1: Low Lift Pumphouse ...............................................................................................11 Figure 2-2: Pipe Leading to Intake ............................................................................................11 Figure 2-3: Pipe Leading to High Lift Pumphouse (Spare Intake Pump and Motor Below) ........12 Figure 2-4: Emergency Intake Skid ...........................................................................................13 Figure 2-5: High Lift Pumphouse...............................................................................................14 Figure 2-6: High Lift Pumps.......................................................................................................14 Figure 2-7: Savona Low Lift Pump System Head Curve............................................................15 Figure 3-1: Sodium Hypochlorite Storage and Dosing System ..................................................17 Figure 4-1: Instrument Panel in High Lift Pumphouse ...............................................................20 Figure 5-1: New Savona Reservoir Under Construction (2017).................................................21 Figure 6-1: Watermains By Size................................................................................................27

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    88 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us