ENVIRONMENTAL CONTROL SYSTEM ROI air ionization SSI BEQUIPPED BEQUIPPED BEQUIPPED BROTHER BINDUSTRIAL EQUIPMENT SYSTEM SERIES ENVIRONMENTAL CONTROL SYSTEM APPLICATION GROW SPACE ASSEMBLY 1316-002 TYPE CHILLED MEDIUM MEDIUM PROPYLENE GLYCOL/WATER MEDIUM RATIO 33.00% GLYCOL MEDIUM SETPOINT 46 F MEDIUM PIPE MATERIAL APPLICATION COPPER *** FLOW RATE - SYSTEM 48 GPM/TOTAL SYSTEM RATED OUTPUT 192000 BTU (FAN COILS) MODULAR PROCESS CHILLER CHILLERS 2 CHILLER SERVICE 460/3/60 REFRIGERANT R422B CHILLER ASSEMBLY 11-1138-313 CHILLER FLOW RATE REQUIRED 24 GPM/EA.**** FAN COILS 4 FAN COIL SERVICE 230/1/60 FAN COIL ASSEMBLY 11-334-103 CLEAN AIR FAN COIL EXPANSION TANK FAN COIL FLOW RATE REQUIRED 12 GPM**** STORAGE TANK CAPACITY 88 GAL STORAGE TANK ASSEMBLY 910-001 EXPANSION TANK CAPACITY 8 GAL EXPANSION TANK ASSEMBLY 905-001 PUMPS 2 (1) STANDBY PUMP SERVICE 460/3/60 STORAGE TANK PUMP NUMBER 517-002 MAXIMUM PUMP FLOW RATE 48 GPM** MAXIMUM PUMP PRESSURE 184 FT HD** STRAINER NUMBER 445-001 PUMP MOTOR CURRENT 10.0 A* COOL MODE CURRENT 68 A* PUMP STRAINER HEAT MODE CURRENT N/A A* Agriculture Environmental conditioning for hydroponics DRY MODE CURRENT N/A A* Grow Pod water temperature maintenance Manufacturing POWER (COOL) 40 kW* Environmental conditioning for finished products *CURRENT/POWER ARE STATED FOR SYSTEM EQUIPMENT ONLY AT FULL SYSTEM OPERATION. VALUES ARE CALCULATED AT DESIGN POINT SPECIFICATIONS, SEE EQUIPMENT Heat exchanging for process machines NAMEPLATES FOR SERVICE SIZING IT Management **PUMP IS SPECIFIED FOR 200 FT. OF 2" CHILLED MEDIUM PIPE (NOT INCLUDED) AND INCLUSIVE SYSTEM EQUIPMENT ONLY. PLEASE PROVIDE PRESSURE DROP DATA FOR Environmental conditioning for server and data storage applications CIRCUIT PIPING AND OTHER ANCILLARY EQUIPMENT (VALVES, HEAT EXCHANGERS, ETC.) FOR ACCURATE PUMP SIZING Heat exchanging for high-capacity server applications ***USE OF CPVC/PVC/ABS MATERIAL FOR CHILLED WATER PLUMBING IS ADVISED AGAINST WHEN POE COMPRESSOR OIL IS USED Medical ****FLOW RATE MAY DIFFER FROM EQUIPMENT DATA SHEET DUE TO BALANCEING REQUIRMENTS Heat exchanging for medical scanning applications SYSTEM FEATURES CHILLERS AND FAN COILS ARE EQUIPPED WITH BROTHER'S EXCLUSIVE SYSTEM STATUS INTERFACE AND REMOTE OUTPUT INTEGRATION HARNESS, FOR MORE INFORMATION, SEE CORRESPONDING UNIT DATA SHEETS (2) 8-TON, CHILLERS (4) 4-TON, FAN COILS (1) CHILLED MEDIUM STORAGE TANK, STAINLESS, INSULATED (1) CHILLED MEDIUM EXPANSION TANK, STAINLESS, INSULATED (2) PUMP, 10 HP, 230/460/3, TEFC* (BALDOR MOTOR) (1) 40-MESH STRAINER *CONFIRM PUMP SPECIFICATIONS WILL MEET YOUR SYSTEM REQUIREMENT, ALTERNATE CAN BE SPECIFIED WHEN REQUIRED. (1) PUMP IS SUPPLIED FOR REDUNDANCY, SYSTEM REQUIRES ONLY (1) PUMP TO PROVIDE FLOW DURING OPERATION. COPYRIGHT 2021 BROTHER INDUSTRIAL EQUIPMENT 842-006 DATA SHEET [email protected] - 772-971-7744 - HTTPS://WWW.BROTHEREQUIPMENT.COM REVISION, 07/12/2021 ECS GROW ROOM INSTALLATION FILTER ACCESS 2 BROTHER 4 BINDUSTRIAL EQUIPMENT 3 LED GROW LIGHTS GROW POD TABLES, PLUMBED TO CONDITION EXCHANGER GROW POD CONDITION EXCHANGER 6 5 ECS EQUIPMENT BY BROTHER 1 (2) GLYCOL CHILLERS 2 (4) GLYCOL FAN COILS 3 (1) STORAGE TANK 4 (1) EXPANSION TANK 5 (2) PUMP, (1) ON STANDBY 6 (1) STRAINER, RETURN LINE 1 EXTERIOR WALL REFERENCE MATERIAL: 843, CHILLED MEDIUM PLUMBING COPYRIGHT 2021 BROTHER INDUSTRIAL EQUIPMENT - THIS ILLUSTRATION IS AN EXAMPLE OF WHAT A TYPICAL HYDROPONICS GROW ROOM MAY CONSIST OF AND MAY NOT DISPLAY ALL NECESSARY EQUIPMENT FOR PROVIDING OPTIMAL GROWING CONDITIONS. PROFESSIONAL GUIDANCE IS SUGGESTED FOR PROPER GROW ROOM ENGINEERING AND BTU REQUIREMENTS..
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages2 Page
-
File Size-