Legato 200 Series Manual Describes the Control of the Pump Using an External Computer Device

Legato 200 Series Manual Describes the Control of the Pump Using an External Computer Device

KDS Legato 200 Series USER’S MANUAL KDS LEGATO 200 SERIES www.kdscientific.com Publication 5617-002 Rev 2.0 Table of Contents 2 KDS Legato 200 Series Table of Contents SUBJECT PAGE NO. General Information ................................................................................................. 6 Safety Information ............................................................................................................................ 6 Warranty and Repair Information .................................................................................................. 7 Manual Description ................................................................................................................ 7 Warranty .................................................................................................................................. 7 Repair Facilities and Parts ...................................................................................................... 7 Serial Numbers ....................................................................................................................... 7 Calibrations ............................................................................................................................. 7 Specifications ................................................................................................................................... 8 Product Overview ...................................................................................................10 Pump Models .................................................................................................................................11 Legato 200 Series Touchscreen Button Reference .....................................................................12 User Selecting an Item from a Menu List ..............................................................................................13 Messages .......................................................................................................................................13 Entering Values ..............................................................................................................................13 ’s Operating Instructions ...................................................................................................................14 Manual Power Connections ........................................................................................................................14 Syringe Loading .............................................................................................................................15 Configuring the KDS Legato 200 Series ................................................................16 Selection Mode ..............................................................................................................................16 Syringe Selection ...........................................................................................................................17 Flow Rate Selection .......................................................................................................................18 Target Volume/Time Selection .....................................................................................................19 Previewing the Configuration .......................................................................................................20 phone 508.429.6809 fax 508.893.0160 KD Scientific Legato 200 Series Syringe Pump User’s Manual e-mail [email protected] web www.kdscientific.com Publication 5617-002-REV-2.0 Table of Contents 3 KDS Legato 200 Series SUBJECT PAGE NO. Configuring the Pump’s General Parameters ..............................................................................20 Setting the Time and Date ....................................................................................................21 Setting the Audible Alarms ...................................................................................................22 For Near End of Run Selection ............................................................................................23 Locking the Touchscreen .......................................................................................................24 Setting the Force Limits ..........................................................................................................25 Setting the Display Brightness ..............................................................................................26 Setting the Pump Address .....................................................................................................27 Setting the RS 232 Baud Rate .............................................................................................27 Resume Run on Power Loss ..................................................................................................28 Setting and Viewing Pump Information ...............................................................................28 Operating the KDS Legato 200 Series ..................................................................29 Running the Pump ..........................................................................................................................30 Custom Program Workflow ..........................................................................................................31 User Step-by-Step Operating Example ........................................................................................32 Configuring Custom Programs ......................................................................................................33 Configuring New Custom Program ..............................................................................................33 ’s Setting a Time Delay......................................................................................................................35 Manual Setting a Time Delay for Program Operation .....................................................................35 Creating a Custom New Program ................................................................................................36 To Create a New User-Defined Program ...........................................................................36 Modifying an Existing/User-Defined Program ............................................................................38 Changing the Order of Steps in a Program........................................................................38 Deleting a Step from a Program ..........................................................................................38 Defining Program Step Parameters ..............................................................................................38 Pump Operation Profiles ...............................................................................................................39 Constant Rate Profile .............................................................................................................40 Ramp Profile ...........................................................................................................................41 Stepped Profile ......................................................................................................................42 Pulse Profile ............................................................................................................................44 phone 508.429.6809 fax 508.893.0160 KD Scientific Legato 200 Series Syringe Pump User’s Manual e-mail [email protected] web www.kdscientific.com Publication 5617-002-REV-2.0 Table of Contents 4 KDS Legato 200 Series SUBJECT PAGE NO. Incorporating Advanced Options ................................................................................................46 Go To Step ............................................................................................................................46 Delay ......................................................................................................................................47 Repeat Step ...........................................................................................................................47 Link Program ..........................................................................................................................48 Stop ........................................................................................................................................48 I/O Event Triggers ................................................................................................................49 I/O Trigger (OUT) .....................................................................................................................50 I/O Event (IN) ............................................................................................................................51 I/O On Event (IN) .....................................................................................................................52 Managing Legato 200 Series Programs .....................................................................................53 Saving a Copy of a Program ...............................................................................................53 Renaming a Program ............................................................................................................53 Appending a Program ..........................................................................................................54

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    89 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us