IDAC-Dose 2.1, an Internal Dosimetry Program for Diagnostic Nuclear

IDAC-Dose 2.1, an Internal Dosimetry Program for Diagnostic Nuclear

View metadata, citation and similar papers at core.ac.uk brought to you by CORE provided by Crossref Andersson et al. EJNMMI Research (2017) 7:88 DOI 10.1186/s13550-017-0339-3 ORIGINAL RESEARCH Open Access IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms Martin Andersson1* , Lennart Johansson2, Keith Eckerman3 and Sören Mattsson1 Abstract Background: To date, the estimated radiation-absorbed dose to organs and tissues in patients undergoing diagnostic examinations in nuclear medicine is derived via calculations based on models of the human body and the biokinetic behaviour of the radiopharmaceutical. An internal dosimetry computer program, IDAC-Dose2.1, was developed based on the International Commission on Radiological Protection (ICRP)-specific absorbed fractions and computational framework of internal dose assessment given for reference adults in ICRP Publication 133. The program uses the radionuclide decay database of ICRP Publication 107 and considers 83 different source regions irradiating 47 target tissues, defining the effective dose as presentedinICRPPublications60and103.Thecomputerprogramwasvalidatedagainst another ICRP dosimetry program, Dose and Risk Calculation (DCAL),thatemploysthesame computational framework in evaluation of occupational and environmental intakes of radionuclides. IDAC-Dose2.1 has a sub-module for absorbed dose calculations in spherical structures of different volumes and composition; this sub-module is intended for absorbed dose estimates in radiopharmaceutical therapy. For nine specific alpha emitters, the absorbed dose contribution from their decay products is also included in the committed absorbed dose calculations. Results: The absorbed doses and effective dose of 131I-iodide determined by IDAC-Dose2.1 were validated against the dosimetry program DCAL, showing identical results. IDAC-Dose2.1 was used to calculate absorbed doses for intravenously administered 18F-FDG and orally administered 99mTc-pertechnetate and 131I-iodide, three frequently used radiopharmaceuticals. Using the tissue weighting factors from ICRP Publication 103, the effective dose per administered activity was estimated to be 0.016 mSv/MBq for 18F-FDG, 0.014 mSv/MBq for 99mTc-pertechnetate, and 16 mSv/MBq for 131I-iodide. Conclusions: The internal dosimetry program IDAC-Dose2.1 was developed and applied to three radiopharmaceuticals for validation against DCAL and to generate improved absorbed dose estimations for diagnostic nuclear medicine using specific absorbed fraction values of the ICRP computational voxel phantoms. The sub-module for absorbed dose calculations in spherical structures 1 mm to 9 cm in diameter and different tissue composition was included to broaden the clinical usefulness of the program. The IDAC-Dose2.1 program is free software for research and available for download at http://www.idac-dose.org. Keywords: Internal dosimetry, ICRP, IDAC, DCAL, Effective dose, Radiopharmaceuticals, Diagnostic nuclear medicine * Correspondence: [email protected] 1Medical Radiation Physics, Department of Translational Medicine, Malmö, Lund University, Skåne University Hospital, SE-205 02 Malmö, Sweden Full list of author information is available at the end of the article © The Author(s). 2017 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. Andersson et al. EJNMMI Research (2017) 7:88 Page 2 of 10 Background radionuclide-specific neutron SAF values, are presented in In radiological protection, it is important to be able to ICRP Publication 133 [21]. perform valid calculations of the absorbed dose in The introduction of more realistic anatomical models organs and tissues of the body for persons exposed to with more detailed biokinetic models regarding the up- external radiation sources and radiation from internally take, distribution, and retention of radiopharmaceuticals distributed radionuclides. Computer programs are needed creates the possibility of more accurate and representative because it is difficult to measure the absorbed dose to absorbed dose estimations. One of the main challenges for organs and tissues. For radionuclides entering the body by medical internal radiation dosimetry is to select an appro- inhalation and ingestion in occupational and environmen- priate biokinetic model describing the uptake, retention, tal exposures, the Dose and Risk Calculation (DCAL) [1] and clearance of the radiopharmaceutical of interest. For program has been used to derive nuclide-specific dose internal absorbed dose calculations for the Reference coefficients published by the International Commission on Person, updating the general biokinetic models includes Radiological Protection (ICRP). In addition, “Internal Dose more realistic representations ofthealimentaryandrespira- Assessed by Computer” (IDAC-Dose) [2, 3] program has tory tract models. Updated nuclear decay data are also been used by ICRP to tabulate dose coefficients for patients available in ICRP Publication 107 [22], and performing undergoing examinations with radiopharmaceuticals in absorbed dose estimations based on the new, more realistic nuclear medicine (mainly intravenous administration, SAF values [21] will allow more detailed absorbed dose sometimes orally or via inhalation). Similar programs calculations and will provide more accurate absorbed dose have been developed by other groups (RADAR [4, 5], etc.). estimations for patients examined with radiopharmaceuti- The ICRP Task Group on “Radiation dose to patients in cals. The aim of this work was to update the IDAC-Dose2.0 diagnostic nuclear medicine” has issued several publica- [23] created to calculate absorbed dose based on earlier tions [6–9] on the absorbed dose to patients from different published SAF values [24] for the ICRP adult computational clinically used diagnostic radiopharmaceuticals using the voxel phantoms [20]. The updated version, IDAC-Dose2.1, IDAC-Dose1.0 program. DCAL has been used by the ICRP is based on the SAF values published by the ICRP [21] and Task Group on “Dose calculations” to estimate doses to implements the computational framework for internal dose occupationally exposed individuals and members of the assessment already used by ICRP for absorbed dose public [10–15]. At that time, the absorbed dose calcula- calculations at occupational and public exposures. If tions using DCAL and IDAC-Dose1.0 were based on the reliable biokinetic data for the substances are available, stylised family anatomical phantoms described by Cristy the program enables calculations of absorbed dose and and Eckerman [16] and based on the data given in ICRP effective dose up to 1252 radionuclides published in Publication 23 for the “Reference Man” [17]. The stylised ICRP Publication 107. This update allows users to perform phantoms were described by linear and quadratic equa- absorbed dose calculations based on biokinetic data gener- tions and included 24 specific organs. In IDAC-Dose1.0, ated in different research programs. radionuclide-specific absorbed dose calculations were in- A secondary aim of this work was to benchmark terpolated from monoenergetic photon-specific absorbed results obtained from IDAC-Dose2.1 with those obtained fractions (SAFs) between 10 and 4 MeV, and electrons using DCAL under the same reference conditions. Both were assumed to be locally absorbed. IDAC-Dose2.1 and the new version of DCAL base their An updated set of reference values for basic anatomical dose calculations on the same ICRP computational frame- and physiological data was given in ICRP Publication 89 work for internal dose assessment [21]. IDAC-Dose2.1 will [18] for both male and female subjects of six different ages be used by the ICRP Task Group on “Radiation dose to (newborn, 1, 5, 10, and 15 years, and adult) based on sta- patients in diagnostic nuclear medicine” for new absorbed tistics for Western Europeans and North Americans. In dose calculations for patients in future ICRP publications, developing guidelines to limit potential stochastic effects whereas the DCAL will be used by the ICRP Task Group (mainly based on cancer statistics) from radiation expos- on “internal dose coefficients” in their publications on ure (external and internal), the ICRP defines an idealised dose estimates for occupational and public intake of person called the “Reference Person” and the dosimetric radionuclides [25, 26]. quantity effective dose [19]. To calculate the effective dose, the equivalent doses to the “Reference Male” and Absorbed dose and effective dose “Reference Female” are averaged. The underlying anatom- MIRD pamphlet 21 [27] defines the mean absorbed dose ical and physiological reference values for the two refer- (D) to a target region (rT) for a time-independent system ence individuals are presented in ICRP Publication 89 [18]. as Eq. 1: Voxel phantoms describing these two adults are given in X ICRP Publication 110 [20], and SAF values for monoener- e DrðÞ¼T ; T D A ðÞrS; T D SrðÞT ←rS ½Gy ð1Þ getic photons, electrons, and alpha particles, as well as rS Andersson et al. EJNMMI Research (2017) 7:88 Page 3 of 10 where Ã(rS, TD) is the time-integrated or cumulated

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    10 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us