Switch Disconnector and Air Circuit Breaker

Switch Disconnector and Air Circuit Breaker

Low voltage Air Circuit Breaker – IZMX Eaton.com SSwitchwitch DDisconnectorisconnector aandnd AAirir CCircuitircuit BBreakerreaker ... with Power Xpert Releases PXR Product Catalog Energizing a world that demands more. We deliver: • Electrical solutions that use less energy, improve power reliability and make the places we live and work safer and more comfortable • Hydraulic and electrical solutions that enable machines to deliver more productivity without wasting power • Aerospace solutions that make aircraft lighter, safer and less costly to operate, and help airports operate more efficiently • Vehicle drivetrain and powertrain solutions that deliver more power to cars, trucks and buses, while reducing fuel consumption and emissions Discover today’s Eaton. Powering businessbusiness worldwide worldwide As a global power management company, we help We provide integrated solutions that help make energy, in customers worldwide manage the power needed for allin allits itsforms, forms, more more practical practical and and accessible. accessible. buildings, aircraft, trucks, cars, machinery and businesses. buildings, aircraft, trucks, cars, machinery and businesses. With 20192014 sales $21.4of $22.6 billion, billion, Eaton Eaton has has approximately approximately Eaton'sEaton’s innovative technologies help customers managemanage 95.000100,000 employees employees around around the the world world and and sells sells products products in electrical, hydraulic and mechanical power more reliably, morein more than than 175 175 countries. countries. effi ciently, safely and sustainably. efficiently, safely and sustainably. Eaton.com Eaton air circuit breakers - for cost-effective, optimized solutions. The IZMX16 is the smallest The IZMX40 is a circuit air circuit-breaker in his class breaker for up to 4000 A in worldwide: a volume of a 3200 A circuit With a volume of only 24 dm3 breaker, without the need to and a front surface of only install any additional “busbar 0.092 m2 it is just slightly extensions” in the connection bigger than the size of a DIN area. A4 sheet of paper! And all this without any loss in terms Tests to integrate it into Eaton of performance. switchgear systems, such as Modan, xEnergy, PowerXpert, Because of its compact size Capitol 20 and Capitol 40 it allows the user to create confirm its outstanding Horizontal Terminal innovative concepts, like to technical performance and install two circuit breakers optimal compatibility thanks side by side in withdrawable to the flexible connection design, in a 600 mm wide system. section. This fact provides for a more cost-effective The modular structure, setup of the section and, integrated detail solutions in addition, it helps to as well as a complete save operating space. And range of accessories and where remote switching is additional functions make required, this volume can it easy to adapt the circuit even accommodate a motor breaker to any of the required for pre-tightening the stored- applications. Optionally it Vertical Terminal energy spring mechanism and can be adapted right at the some magnetic coils for the factory – without any extra on/off command. cost or additional installation work at the circuit breaker. More performance in less space is simply impossible. Safety - individual solutions combined with IZMX. Adding individual solutions These solutions include: to IZMX circuit breakers pro- • ARMSTM vides both more protection • ARCON® for systems and more safety • Zone selectivity for personnel in case there is • Remote switching a failure. And it also reduces • Testing and documenting the risk of unintended inter- with PXPM ruptions of operation. SAFETY ARMSTM (Arcfl ash Reduction Maintanance System) Eaton’s patented Arcfl ash The Arcfl ash Reduction Main- Reduction Maintenance System tenance System function is AMRS technology provides activated either directly on the maintenance staff improved circuit breaker through a local safety of downstream mainte- switch or remotely through nance locations using a simple communications or a contact and reliable method to reduce input. fault clearing times and energy in an arc fl ash event (radiation, Arcfl ash Reduction Mainte- sound, pressure, temperature). nance System is optional on both PXR20 and PXR25 trip Arcfl ash Reduction Mainte- units. nance System uses a separate analog trip circuit providing faster signal processing and interruption times than the standard (digital) “instantane- ous” protection. ARCON® IZMX breakers, combined with SAFETY ARCON®, help users to avoid damage and to protect people against arc faults as they can effectively be brought under control within 2 ms. They also protect against arc fl ashes that – due to their impe- dance - would not even cause a protective device to react. Zone selectivity ZSI CB1 Now always on board an can be tsd= enabled. 200 ms Circuit breakers are directly This reduces the thermal and connected to a signal line, dynamical load that protect the CB2 without any additional modules. system in addition. In cases of tsd= So, in case of short circuits, a signal wire damage the back- 100 ms they ensure that only the circuit up time selectivity ensures the breaker immediately upstream selectivity of the system. the point of failure will break a CB3 CB4 short-circuit without delay. For additional safety of main- t = t = sd sd tenance staff we recommend 0 ms 0 ms The advantage of the zone a combination with ARMS® to selectivity feature – compared reduce the released amount of to ordinary time selectivity - is energy even further. the signifi cantly reduced delay time until tripping. Remote switching Remote switching requires two Safety: If the second switching magnetic coils (shunt trip and action was an ON action, a third closing release). action for switch-off or tripping These coils will activate the through the energy of the mechanism of the ON and OFF spring will be ensured. buttons. After two switching actions have been carried out, Safety: OFF commands will a stored-energy spring mecha- always be given priority. A nism needs to be retightened permanent command for the manually. With an additional operating-current trip enables motor drive, the retightening the user to lock the circuit brea- action can be automated. ker in the OFF position. Thanks to the powerful stored- energy spring, the circuit breaker will carry out the switch command sent to the magnetic coil in less than 35 ms. So the IZMX series circuit breakers are suitable for synchronisation tasks. Easy inspection and maintenance Inspection and maintenance can be conveniently performed on the draw-out breaker as the primary fi nger clusters (blue) and levering mechanism are part of the breaker instead of the cassette. Eaton also offers many fi eld installable accessories and parts, extending the life of the breaker. Breaker rear side (Drawout breaker) The next generation trip unit plat- form: Power Xpert Release (PXR) The higher resolution dot matrix zone selectivity (ZSI), battery communication function and code has been added for easier display has been enhanced condition and rated current In. for security, a password can be identifi cation and to access to be always active, cons- All data can be transferred via added to avoid unauthorised additional information. tantly displaying the status of Modbus, Profi bus or Ethernet changes. In addition, a QR Power Xpert Release (PXR) with multiple new features Software Power Xpert Protection Manager (PXPM) for interaction with PXR • Modbus on board for PXR25 (optional for • Dis-/enable functions PXR20) • Reading/Changing set- • Large LCD combined with cursor operati- tings (not basic protection on for more function and information settings) • Battery status, ZSI and In visible anytime • Waveform capture • ZSI – the better selective protection is • Multiple test procedures always on board with fi nal test protocol print including date/time stamp • Password protection • Print settings and curves • Rating plug programmable Using the software is easy and self explaining. The cursor abo- • LSI protection can be changed to LI ve a select able function opens a window with its explanation. (without time selectivity T = 0) or LS sd Depending on the selection next logical selection opens. (without Instantaneous li = 0 ^100% selective) • 3 free alarm contacts available Testers no longer require specialized test tools thanks to the much better software solution in combination with the • USB port for testing and additional func- integrated secondary injection test hardware. tion setup via PC and software PXPM • QR code for easier identifi cation and The Power Xpert Release trip unit further information platform enables engineers to con- fi gure and test circuit breakers from a PC via a USB port. As a result, it is easier for users to interact with the trip unit and store or print test data so they can improve their control and maintenance regimes. USB • Improved Diagnostics with breaker health Commercial (graph), events and run time cable Load your settings and record them. If any values are changed a “fi nal setting adjustments” screen shows the original and revised settings, highlighting any that were modifi ed. The sheet can be saved or printed. High current circuit breakers, to ensure they continue to work inject overloads, short circuits, the Software Power Xpert Pro- for example those used in high reliably in case of over-currents, ground faults , do internal cur- tection Manager (PXPM). power distribution systems in and therefore prevent expensi- rent transformer test including industry, are confi gured and ve downtime. This new unit al- its wiring, test with or without periodically tested by end users lows technicians to simulate or tripping and much more using Dis-/Enable or change settings, enlarge tripping curves and print curves for documentation. Utilizing the easy-to-use dashboard, Control Mode can be selected allowing diagnostic and meter data to be reset. In Test Mode individual phases can be tested against values entered as current value or as a multiplier of individual settings. Select the function you want to test and choose the test cur- rent as value or multiplier of setting.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    100 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us