Polysorbate 80

Polysorbate 80

Stage 6 Harmonization Official May 1, 2016 Polysorbate 1 . Table 1 (Continued) Polysorbate 80 Mixture of the Following Composition Portions of the monograph text that are national USP text, Substances (%) and are not part of the harmonized text, are marked Methyl oleate 20 N with symbols ( .N) to specify this fact. Methyl eicosenoate 10 Sorbitan, mono-9-octadecenoate, poly(oxy-1,2-ethanediyl) Methyl behenate 10 derivs., (Z)-; Methyl lignocerate 10 Polyoxyethylene 20 sorbitan monooleate [9005-65-6]. Chromatographic system DEFINITION (See Chromatography 〈621〉, System Suitability.) Polysorbate 80 is a mixture of partial esters of fatty acids, Mode: GC mainly oleic acid, with sorbitol and its anhydrides ethox- Detector: Flame ionization ylated with approximately 20 moles of ethylene oxide for Column: 0.32-mm × 30-m G16 on fused silica; film each mole of sorbitol and sorbitol anhydrides. thickness 0.5 µm Temperatures IDENTIFICATION Injection port: 250° • A. It meets the requirements of the test for Composition Detector: 250° of Fatty Acids. Column: See Table 2. Change to read: Table 2 Hold Time LN LN • . .LNF34B. INFRARED ABSORPTION 〈197F〉 . .LNF34 Initial Tempera- Final at Final Tempera- ture Tempera- Tempera- ASSAY ture Ramp ture ture (°) (°/min) (°) (min) Change to read: 80 10 220 Ð 220 Ð 220 40 • COMPOSITION OF FATTY ACIDS Diluent: 20 g/L of sodium hydroxide in methanol Carrier gas: Helium L .Boron trifluoride±methanol solution: 140 g/L of bo- Linear velocity: 50 cm/s ron trifluoride in methanolLNF34 Injection volume: 1 µL Saturated sodium chloride solution: Sodium chloride System suitability and water (1:2). Before use, decant the solution from Samples: Reference solution A and Reference solution B any undissolved substance and filter, if necessary. Suitability requirements Reference solution A: Prepare 0.50 g of the mixture of Resolution: NLT 1.8 between the peaks due to calibrating substances with the composition described methyl oleate and methyl stearate, Reference solu- in Table 1. Dissolve in heptane, and dilute with hep- tion A tane to 50.0 mL. Theoretical plates: NLT 30,000 calculated for the Reference solution B: Reference solution A in heptane peak of methyl stearate, Reference solution A (1 in 10) Signal-to-noise ratio: NLT 5 for the peak of methyl Reference solution C: Prepare 0.50 g of a mixture of myristate, Reference solution B fatty acid methyl esters, which corresponds to the Analysis composition of the substance to be examined. Dissolve Sample: Sample solution in heptane, and dilute with heptane to 50.0 mL. Identify the peaks from Reference solution C. Calculate [NOTEÐCommercially available mixtures of fatty acid the percentage of each component in the Sample methyl esters may also be used.] solution: Sample solution: Dissolve 0.10 g of Polysorbate 80 in 2 mL of Diluent in a 25-mL conical flask, and boil under Result = (AC/AT) × 100 L a reflux condenser for 30 min. Add 2.0 mL of .Boron AC = peak area for the component of interest trifluoride±methanol solutionLNF34 through the con- denser, and boil for 30 min. Add 4 mL of heptane AT = total area of all peaks related to fatty acids through the condenser, and boil for 5 min. Cool, add Acceptance criteria: See Table 3. 10.0 mL of Saturated sodium chloride solution, shake for about 15 s, and add a quantity of Saturated sodium Table 3 chloride solution such that the upper phase is brought into the neck of the flask. Collect 2 mL of the upper Acceptance Acceptance phase, wash with three quantities, each of 2 mL, of Criteria, Criteria, water, and dry over anhydrous sodium sulfate. Name NMT (%) NLT (%) Myristic acid 5.0 Ð Palmitic acid 16.0 Ð Table 1 Palmitoleic acid 8.0 Ð Mixture of the Following Composition Stearic acid 6.0 Ð Substances (%) Oleic acid Ð 58.0 Methyl myristate 5 Linoleic acid 18.0 Ð Methyl palmitate 10 Linolenic acid 4.0 Ð Methyl stearate 15 Methyl arachidate 20 2015 The United States Pharmacopeial Convention All Rights Reserved. Stage 6 Harmonization 2 Polysorbate Official May 1, 2016 IMPURITIES Table 4 (Continued) ESIDUE ON GNITION • R I Hold Time Sample: 2.00 g Initial Tempera- Final at Final Analysis: Heat a silica or platinum crucible to redness Tempera- ture Tempera- Tempera- for 30 min, allow to cool in a desiccator, and weigh. ture Ramp ture ture Evenly distribute the Sample in the crucible. Dry at (°) (°/min) (°) (min) 100°±105° for 1 h and ignite to constant mass in a muffle furnace at 600 ± 25°, allowing the crucible to 250 Ð 250 5 cool in a desiccator after each ignition. Flames should Split ratio: 3.5: 1 not be produced at any time during the procedure. If Carrier gas: Helium after prolonged ignition the ash still contains black par- Flow rate: 4.0 mL/min ticles, take up with hot water, pass through an ashless Injection volume: 1 mL filter paper, and ignite the residue and the filter paper. System suitability Combine the filtrate with the ash, carefully evaporate Sample: Reference solution to dryness, and ignite to constant mass. [NOTEÐThe relative retention times for ethylene oxide, Acceptance criteria: NMT 0.25% acetaldehyde, and dioxane are 1.0, 0.9, and 1.9, re- spectively. The retention time for ethylene oxide is Delete the following: about 6.5 min.] Suitability requirements N ·. Resolution: NLT 2.0 between the peaks due to acet- • HEAVY METALS, Method II 〈231〉: NMT 10 ppmN· (Official 1-Dec-2015) aldehyde and ethylene oxide • ETHYLENE OXIDE AND DIOXANE Analysis Ethylene oxide standard solution: Dilute 0.5 mL of a Samples: Sample solution A and Sample solution B commercially available solution of ethylene oxide in Calculate the content of ethylene oxide: methylene chloride (50 mg/mL) with water to 50.0 mL. [NOTEÐThe solution is stable for 3 months, if stored in Result = (2 × CEO × AA)/(AB − AA) vials with a Teflon-coated, silicon membrane and crimped caps at −20°.] Allow to reach room tempera- CEO = concentration of ethylene oxide in Sample ture. Dilute 1.0 mL of this solution with water to solution B (µg/mL) 250.0 mL. AA = peak area of ethylene oxide from Sample Dioxane standard solution: Dioxane in water (v/v) 1 solution A in 20,000 AB = peak area of ethylene oxide from Sample Acetaldehyde standard solution: 0.01 mg/mL of acet- solution B aldehyde in water Calculate the content of dioxane: Standard solution: Dilute 6.0 mL of Ethylene oxide Result = (2 × D × CD × AA′)/(AB′ − AA′) standard solution and 2.5 mL of Dioxane standard solu- tion with water to 25.0 mL. D = density of dioxane, 1.03 g/mL Sample solution A: Transfer 1.0 g of Polysorbate 80 to CD = concentration of dioxane in Sample solution B a 10-mL headspace vial. Add 2.0 mL of water, and seal (µL/mL) the vial immediately with a Teflon-coated, silicon mem- AA = peak area of dioxane from Sample solution A brane and an aluminum cap. ′ AB′ = peak area of dioxane from Sample solution B Sample solution B: Transfer 1.0 g of Polysorbate 80 to Acceptance criteria: NMT 1 ppm for ethylene oxide; a 10-mL headspace vial. Add 2.0 mL of the Standard NMT 10 ppm for dioxane solution, and seal the vial immediately with a Teflon- coated, silicon membrane and an aluminum cap. SPECIFIC TESTS N Reference solution: Transfer 2.0 mL of Acetaldehyde • .SPECIFIC GRAVITY 〈841〉: 1.06±1.09N standard solution and 2.0 mL of Ethylene oxide standard solution to a 10-mL headspace vial, and seal the vial immediately with a Teflon-coated, silicon membrane Change to read: and an aluminum cap. N Chromatographic system • .·.VISCOSITYÐCAPILLARY METHODS 〈911〉 or VISCOSITYÐ (See Chromatography 〈621〉, System Suitability.) ROTATIONAL METHODS 〈912〉:· (CN 1-May-2015) 300±500 cen- Mode: Headspace GC tistokes at 25°N Detector: Flame ionization 1 Column: . 0.53-mm × 50-m G27 on fused silica; film Change to read: thickness 5 µm Temperatures • FATS AND FIXED OILS, Acid Value 〈401〉 Injection port: 85° L .Light petroleum: It has the following properties: a Detector: 250° clear, colorless, flammable liquid without fluorescence; Column: See Table 4. practically insoluble in water; miscible with alcohol; density at 20° about 0.720; distillation range 100°± 2 Table 4 120°; water content NMT 0.03%. .LNF34 Sample solution: Dissolve 5.0 g in 50 mL of a mixture Hold Time L Initial Tempera- Final at Final of equal volumes of alcohol and .Light petroleumLNF34 Tempera- ture Tempera- Tempera- (previously neutralized with 0.1 N potassium hydroxide ture Ramp ture ture or 0.1 N sodium hydroxide), using 0.5 mL of phenol- (°) (°/min) (°) (min) phthalein TS as the indicator. If necessary, heat to about 90° to dissolve the substance to be examined. 70 10 250 Ð L2 . Petroleum ether; boiling range 100°±140°; [CAS 64742-49-0] from Fisher 1 . CP-Sil 8 CB is suitable. Scientific; catalog number AC23302-0025 is suitable.LNF34 2015 The United States Pharmacopeial Convention All Rights Reserved. Stage 6 Harmonization Official May 1, 2016 Polysorbate 3 Analysis: Titrate the Sample solution ·.with 0.1 N potas- Analysis: Transfer the Sample into a 100-mL beaker, sium hydroxide VS or 0.1 N sodium hydroxide VS· (ERR and dissolve with 20 mL of glacial acetic acid. Add 1-Dec-2014) until the pink color persists for at least 15 s. 1 mL of Saturated potassium iodide solution, and allow When heating has been applied to aid dissolution, to stand for 1 min. Add 50 mL of carbon dioxide-free maintain the temperature at about 90° during the water and a magnetic stirring bar.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    3 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us