Solar & Hydronic Heating

Solar & Hydronic Heating

TECHNICAL FEATURE This article was published in ASHRAE Journal, February 2012. Copyright 2012 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically or in paper form without permission of ASHRAE. For more information about ASHRAE Journal, visit www.ashrae.org. A B Photo 1a (left): Small commercial solar combisystem. Photo 1b (right): Residential solar combisystem. Integrating Solar & Hydronic Heating In Residential and Small Commercial Systems By Bristol Stickney uses, not just a single water tank. In a combisystem, it is typical for a large his article and the following companion article, “Advantages group of collectors to provide heat for space heating, water heating, and other Tof Integrated Control in Solar Combisystems,” share our field uses such as boiler preheat, pools, spas, ice melt, and heat storage. The piping experience in the solar heating industry for those seeking better involved in these systems can seem complex, and the control systems for- ways to apply solar thermal technology in their heating system de- midable. But the technology has ma- tured and the energy savings can be signs. This article discusses applications where hot water produced significant, so solar heating should not be overlooked. by solar collectors can be easily allocated to multiple uses with a The information presented here is es- simple piping configuration and straightforward control strategies. sentially a report from the field, draw- ing upon the experience of more than The detailed control of these systems is more thoroughly described 100 solar-heated combisystems in- stalled and operating over the past five in the companion article. to six years. We have focused on pres- After a solar heating professional be- solar combisystems. In these systems, About the Author comes proficient with solar water heat- the collector arrays become larger, and Bristol Stickney is chief technical officer at Solar- ers, the next logical step is to delve into the heat is distributed to multiple end- Logic in Santa Fe, N.M. 26 ASHRAE Journal ashrae.org February 2012 TECHNICAL FEATURE surized, closed loop glycol/hydronic solar collector systems, how hard it would be to hook up some other heating jobs to since these systems can be applied in a variety of building get additional benefit from larger collectors. The design pro- geometries and orientations with few limitations. Our results cess can be surprisingly predictable and typically includes and observations have helped to formulate our own recom- the following items: mended best practices, presented here, which can be applied • Solar collectors; directly to solar heating installations in residential and small • Solar hot water tanks; commercial buildings (see examples in Photos 1a and 1b). • Solar heated floors; The discussion presented here targets new and retrofit heat- • Hot water baseboards or radiators; ing systems in small buildings (less than 10,000 ft2 [929 • Hydronic boiler (conventional fuel or other on-demand m2]) using hydronic heating systems. We have found that a heat sources); and standardized and modular approach to the design, installa- • Intermittent heat sources like a wood burner or waste heat tion and control of solar combisystems can greatly improve from an electric generator. the speed and reliability with which they are deployed. Then, we need to answer some questions: • Can we connect them all together? Why Active Solar Hydronics? • Can we send extra heat to: the pool, spa, ice melt, hot air Closed loop hydronic solar heating collector systems are fan coils, etc.? seamlessly compatible with hydronic boilers, hot water radia- • Do we need big water tanks for heat storage? tors, domestic hot water and radiant-heated mass floors. Both • How do we control solar overheating? the solar equipment and the conventional systems operate Every new choice represents a change in the design, differ- along the same principles, using similar fluids and fluid pres- ent piping connections, additional components, various tem- sure, and have compatible temperature ranges. Conventional perature requirements and different controls. building construction practices for hydronic heat distribution systems do not need to be altered or relearned in most cases Solar Combisystem Dilemma when solar heat is to be included. Multiple heat sources and multiple heating loads can be Closed loop, pressurized solar collectors can be mounted connected in a bewildering variety of different ways. In our re- in a variety of ways, including ground mounting, roof mounts gion (Northern New Mexico), the most typical solar-hydronic and wall mounts, allowing for flexibility in their application, combisystem includes: and, therefore, compatibility with existing and new buildings • A solar heat collector array; without any further technical development. Closed loop active • A gas or propane hydronic boiler; solar heating systems are assembled, operated and maintained • A domestic water heater with in-tank heat exchanger; and in much the same way hydronic boiler systems are, making • A radiant heated floor typically divided into several heat- them compatible with the skills of our existing hydronic in- ing zones. stallers. I call this application “Solar Combisystem 101” because these basic features have been duplicated so many times for Solar Heating Opportunity small buildings in recent years.1 This includes only four items, Hundreds of thousands of hot water boilers are installed in two heat sources and two heat loads. Yet, if you present these the U.S. every year. requirements to three different heating equipment suppliers, Even if only a small fraction of them could easily benefit you will likely get three different piping and wiring plans with from supplemental solar hydronic heat collectors, that still tees, motorized valves and pumps in different locations, as represents thousands of solar thermal installations each year. well as some often cryptic control strategies (or none at all), Also, the backlog of hydronic heating systems installed over which will complete the confusion. the past 20 years represents an enormous opportunity for prac- This is what happened in the unfortunate installation seen tical solar thermal retrofits. Clearly, millions of homes and in Photo 2a. Several equipment suppliers and three different other buildings use hydronic (hot water) heating systems that installers made a valiant attempt to install a Combi 101 system could benefit from the fuel offset that solar heating can easily in a small residence in Santa Fe, N.M. Each supplier had its provide. own idea about plumbing connections and controls, and each installer eventually gave up in confusion. The result was an Typical Solar Heating Design Thought Process unfinished heating system, and the plumbing nightmare seen Anytime someone starts thinking about adding solar heat in the photo. collectors to a small building project, the thought process Proper design and control can be a daunting challenge to invariably proceeds along the same lines. First, he thinks any mechanical installer. The makers and suppliers of the about a solar water heater with one or two collectors. Next, components, to their credit, have put a lot of thought into all he wonders if some of that heat could be connected to the the different ways their equipment might be installed, and gen- floors or to other space heating jobs. If so, then maybe a few erally provide plenty of choices, suggestions and alternatives more collectors would be worthwhile. Finally, he wonders so as not to limit the installer. But, all these choices can (and February 2012 ASHRAE Journal 27 do) serve as barriers to rapid and reli- Primary Loop able deployment of solar thermal com- Boiler bisystems. Each alternative plumbing A B Pump Relay configuration represents a slightly dif- Controls ferent operating sequence (and a differ- ent control strategy to go with it) that Pump the installer must understand explicitly if it is to start-up and operate success- Tank fully over the long term. Solution by Design Heat Exchanger Let’s pause for a moment to reflect Tank on what we are ideally trying to accom- Tank Tempering plish with a combisystem piping con- Pump figuration. We have multiple heat sources feed- ing multiple heat loads. Some of the heat sources are only available intermit- Boiler tently, but those are typically the most Photo 2a (left): The dilemma: chaos. Photo 2b (right): The solution: elegance. desirable with the lowest fuel cost. Not all the heating loads require the same temperature, and some the circulator pumps to join together without interfering with have intrinsic heat storage capacity. Water heat-storage tanks one another. This can be accomplished with primary/second- can act both as heat sources and heat loads, so the piping con- ary piping using closely spaced tees to attach the secondary figuration needs to allow for this. loops, which plug into the primary loop with a two-pipe con- We want to deliver solar heat to any job that needs heat, nection. giving it top priority whenever it is available because of the Figure 1 illustrates this concept as it applies to a small solar lower fuel cost. If solar heat is used directly (instead of stored) heating system. This diagram is typical of many smaller so- as soon as it arrives, the delivered solar thermal efficiency is lar-heated homes in Northern New Mexico, where the glycol maximized when the energy loss associated with heat stor- boiler fluid circulates in a pressurized, closed system, directly age, extra pumping and multiple heat exchangers is eliminat- from the solar collectors into the floors, the boiler, and other ed. The same capability is needed for any other intermittent heating equipment. This eliminates the need for a primary source of heat when they are connected. heat exchanger (separating the outdoor fluid from the indoor So, a piping configuration is needed that allows any heat fluid), which lowers the cost of these small installations, and source to connect to any heat load whenever the temperature improves the solar thermal system efficiency.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    7 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us