Documentation Checked: from 2020-08-05 to 2020-10-12

Documentation Checked: from 2020-08-05 to 2020-10-12

Technical Report Technical Report No.: 61.327.20.017.01 Date: 2020-10-12 HSIANG FU CHIA ENTERPRISE CO., LTD. NO. 41, Lane 737, Jiadian Rd., Homei Town 50860 Changhua County, Client: TAIWAN Contact person: Ms. Sandy Chen HSIANG FU CHIA ENTERPRISE CO., LTD. NO. 41, Lane 737, Jiadian Rd., Homei Town 50860 Changhua County, Manufacturing place: TAIWAN Contact person: Ms. Sandy Chen Product: Steps (Dome type) Test subject: Type: T5, T6, T7, T8 EK5/AK1 19-01:2019 EN 14183:2003 Test specification: AfPS GS 2019:01 PAK • Inspection according to specified requirements to realize the conformity with the Produktsicherheitsgesetz – ProdSG • Inspection according to the test specification Purpose of examination: The test result show that the presented product is in compliance with the specific requirements. Test result: Requirements of AfPS GS 2019:01 PAK have been evaluated and found to be met by evaluation and/or relevant test 7 Rev. Rev. - Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details please see testing and certification regulation, chapter A-3.4. TTW0902.02E - Report No.: 61.327.20.017.01 TEL: +886 2 2898 6818 TÜV SÜD Asia Ltd. Taiwan Branch ITC Rev.: 01 FAX: +886 2 2895 1598 7F, No.37, Section 2, Zhongyang S. Road, Date: 2020-10-12 www.tuvsud.com Beitou District, 11270, Taipei City, Taiwan Page 1 of 5 Doc No.: Doc No.: Technical Report 1. Description of the test subject 1.1 Function Manufacturer’s specification for intended use: Step stools for indoor use. Manufacturer’s specification for predictive use: According to the user manual Light Gray Dark Gray Black T5 T6 T7 7 Rev. Rev. - TTW0902.02E - Report No.: 61.327.20.017.01 TEL: +886 2 2898 6818 TÜV SÜD Asia Ltd. Taiwan Branch ITC Rev.: 01 FAX: +886 2 2895 1598 7F, No.37, Section 2, Zhongyang S. Road, Date: 2020-10-12 www.tuvsud.com Beitou District, 11270, Taipei City, Taiwan Page 2 of 5 Doc No.: Doc No.: Technical Report T8 1.2 Consideration of the foreseeable use Not applicable Covered through the applied standard Covered by the following comment Covered by attached risk analysis 1.3 Technical Data Dome type step stool for indoor use Maximum load: 150 kg Plastic material: PP Castor: Ø 30 x 15 mm Spring for castors= Ø 1.0 mm T5: Top: Ø 283 mm Bottom: Ø 414 mm Height: 370 ± 2 mm Weight: 2.1 kg T6: Top: Ø 284 mm Bottom: Ø 380 mm Height: 260 mm Weight: 1.6 kg T7: 7 Top: Ø 288 mm Rev. Rev. - Bottom: Ø 433 mm Height: 418 ± 2 mm Weight: 2.9 kg TTW0902.02E - Report No.: 61.327.20.017.01 TEL: +886 2 2898 6818 TÜV SÜD Asia Ltd. Taiwan Branch ITC Rev.: 01 FAX: +886 2 2895 1598 7F, No.37, Section 2, Zhongyang S. Road, Date: 2020-10-12 www.tuvsud.com Beitou District, 11270, Taipei City, Taiwan Page 3 of 5 Doc No.: Doc No.: Technical Report T8: Top: Ø 294 mm Bottom: Ø 442 mm Height: 418 ± 2 mm Weight: 2.9 kg 2. Order 2.1 Date of Purchase Order, Customer’s Reference 2020-06-02 2.2 Receipt of Test Sample, Condition, Location 7/15/2020, No Defects found. TÜV SÜD Asia Ltd. Taiwan Branch, Mechanical Safety Department No.73-3, Sec. 2, Zhongxing Rd., Dali Dist., 41254 Taichung City, Taiwan Testing: From 2020-07-21 to 2020-09-22 2.3 Date of Testing Documentation checked: From 2020-08-05 to 2020-10-12 TÜV SÜD Asia Ltd. Taiwan Branch, Mechanical Safety Department 2.4 Location of No.73-3, Sec. 2, Zhongxing Rd., Dali Dist., 41254 Taichung City, Testing Taiwan 2.5 Points of Non-Compliance or Exceptions of the Test Procedure • None 3. Test Results • Decision rule according to IEC Guide 115:2007, clause 4.4.3, 4.5.1 was applied. 3.1 Positive Test Results • PAH (Report No.: 61.406.20.0085.01 Dated: 2020-08-28) 7 • PAH (Report No.: 61.406.20.0084.01 Dated: 2020-08-28) • Mechanical safety (Report No.: 61.327.20.017.01 Dated: 2020-10-13) Rev. Rev. - TTW0902.02E - Report No.: 61.327.20.017.01 TEL: +886 2 2898 6818 TÜV SÜD Asia Ltd. Taiwan Branch ITC Rev.: 01 FAX: +886 2 2895 1598 7F, No.37, Section 2, Zhongyang S. Road, Date: 2020-10-12 www.tuvsud.com Beitou District, 11270, Taipei City, Taiwan Page 4 of 5 Doc No.: Doc No.: Technical Report 3.2 Points of Non-Compliance according to the test specification • None 4. Remark The user manual has been examined according to the minimum requirements described in the product standard. The manufacturer is responsible for the accuracy of further particulars as well as of the composition and layout. Your production facility is currently on a e.g. Annual (12 month), Bi-Annual (6 month), or Quarterly (3 month) inspection cycle. 5. Documentation • CDF • User manual • Type label 6. Summary The test specifications are met. Hardlines-MES TÜV SÜD ASIA LTD., Taiwan Branch Taichung Office, Mechanical Safety TÜV SÜD Group Tested by: Daniel Wu Approved by: Edison Wang 7 Rev. Rev. - TTW0902.02E - Report No.: 61.327.20.017.01 TEL: +886 2 2898 6818 TÜV SÜD Asia Ltd. Taiwan Branch ITC Rev.: 01 FAX: +886 2 2895 1598 7F, No.37, Section 2, Zhongyang S. Road, Date: 2020-10-12 www.tuvsud.com Beitou District, 11270, Taipei City, Taiwan Page 5 of 5 Doc No.: Doc No.: .

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    5 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us