Characterization of Vanadium Dioxide by Scanning Probe Microscopy Thomas P. Campbell1, Robert E. Marvel2, Benjamin W. Schmidt3, Richard F. Haglund, Jr.2,4 1Institute of Engineering, Murray State University, 2Interdisciplinary Graduate Program in Materials Science, Vanderbilt University, Nashville, TN , 3Director, VINSE Labs, Vanderbilt University, 4Physics Department, Vanderbilt University, Nashville, TN Printing: This poster is 48” wide by 36” high. It’s designed to be printed on a INTRODUCTION SCANNING PROBE MICROSCOPY RESULTS large VO thin films that are part of nanoscale device architectures often cannot be Vanadium dioxide (VO2) experiences a metal-to-insulator transition from a 2 monoclinic, semiconductor phase to a rutile, metallic phase at approximately 70° C. characterized by typical optical transmission or reflection measurements. Scanning probe microscopy techniques such as tunneling and thermal microscopy offer a During this transition, a vast change in physical, thermal, electrical, and optical viable alternative. properties are observed. Advantages of scanning probe microscopy: This transition can be initiated by: • High lateral and vertical resolution • Probing can take place in air instead of Customizing the Content: • Temperature change • Optical pumping • Many SPM techniques can be used vacuum • Electric field • Mechanical stress with the same instrument • Scans can collect multiple types of data The placeholders in this In films, this transition does not occur all at once at once • Grains switch individually formatted for you. • ‘Puddles’ of metallic VO2 form during transition SCANNING THERMAL MICROSCOPY (SThM) placeholders to add text, or click Above are the SThM images generated by a single scan at 73 °C. The left image is Scanning thermal microscopy uses a physical probe consisting of a cantilever and a the topography image, and right is the thermocouple voltage. an icon to add a table, chart, sharp ( <100 nm radius) tip. This tip is actually a very small thermocouple, allowing • The height map and thermal image above allow us to compare topography and the user to collect temperature data and topography data simultaneously. potential phase coexistence SmartArt graphic, picture or • The metallic phase is more thermally conductive than the insulator phase of VO2 which allows more heat to flow from the sample to the probe tip multimedia file. • Surface-to-tip heat flow is strongly influenced by topography • In the valleys between grains, the probe tip is in contact with more surface area, T allowing more heat to flow from text, just click the Bullets • No usable STM images were acquired • The probe left scarred areas (image at left, button on the Home tab. 20 μm wide) on the sample surface. Figure 1 (Above): Electrical Conductivity of VO2 with respect to temperature -Volker Eyert, Ann. Phys. (Leipzig) 11 (2002) 9 • A sharper tip or a vacuum may be required Figure 2 (Right): SNIM images of partially switched VO2 at different temperatures through the phase transition If you need more placeholders for - M. M. Qazilbash et al, Science 318, 1150124 (2007) titles, SCANNING TUNNELING MICROSCOPY (STM) make a copy of what you need and CONCLUSIONS AND FUTURE WORK APPLICATIONS OF VO2 Scanning tunneling microscopy utilizes a sharp etched or precision-cut tungsten wire drag it into place. PowerPoint’s to probe the sample surface. A DC bias voltage is held between the tip and sample • In the future, we plan to use scanning probe microscopy to explore the The VO phase transition makes it an attractive material for many applications: 2 surface, and the tip is brought into very close proximity with the sample ( approx. 1 percolation of the vanadium dioxide phase transition in thin films. • Passive thermal cooling devices • Resonators (below) nm). This allows a measureable tunneling current to flow into the tip. As the tip Smart Guides will help you align it moves horizontally across the surface, it is adjusted vertically to maintain a consistent • SThM seems a viable method for distinguishing metallic from insulator VO2, as the • Waveguide couples • Ultrafast field effect transistors current, and a detailed electron density contour map is obtained. phases have differing thermal conductivities. with everything else. • Optical modulators • STM will potentially give us the highest resolution images, and is the only technique that will allow metallic VO2 nanopuddles to be seen. Want to use your own pictures At right: SEM image of a Silicon micro ring instead of ours? No problem! Just resonator, consisting of a Silicon ACKNOWLEDGEMENTS absorber (radius of 1.5 μm) with a 500 nm length patch of VO (colored red) right 2 The authors thank Vanderbilt University, the Vanderbilt Institute of Nanoscale Science which can be switched optically. and Engineering (VINSE), all members of the Haglund group, and Dr. Bo Choi for his Ryckman et al, Optics Express, 10753 valuable insight into STM. Change Picture. Maintain the (2013) This research is funded by the National Science Foundation grant DMR-1263182. proportion of pictures as you resize by dragging a corner..

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    1 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us